===================== Product Identification =====================
MSDS NAME:CYALUME CHEMICAL LIGHTSTICK (6 IN HI-INT)
NIIN:01-106-4230
MSDS Number: BGMDB
=== Responsible Party ===
Company:AMERICAN CYANAMID CO
Emergency Phone Num:201-835-3100
CAGE:83289
=== Contractor Identification ===
Company:AMERICAN CYANAMID CO CYTEC INDUSTRIES DIV CHEMICAL LIGHT
DEP
Address:5 GARRET MOUNTAIN PLZ
Box:City:LITTLE FALLS
State:NJ
ZIP:07424
Country:US
Phone:201-831-2000/201-357-3100
CAGE:83289
============= Composition/Information on Ingredients =============
Name:DIMETHYLPHTHALATE (SARA III)
CAS:131-11-3
RTECS #:TI1575000
Fraction by Wt: 25%
OSHA PEL:5 MG/M3
ACGIH TLV:5 MG/M3; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
Effects of Overexposure:NO SIGNIFICANT HEALTH HAZARD KNOWN
======================= First Aid Measures =======================
First Aid:EVEN THOUGH NO HAZARDS ARE KNOWN,MFR RECOMMENDS, FLUSHING ANY
AFFECTED AREAS (ESPECIALLY EYES) WITH WATER FOR 15 MIN., ESPECIALLY
SINCE GLASS CHIPS MAY BE PRESENT.
===================== Fire Fighting Measures =====================
Flash Point:200F CC
Lower Limits:UNK
Upper Limits:UNK
Extinguishing Media:WATER,CARBON DIOXIDE OR DRY CHEMICAL
Fire Fighting Procedures:USE SELF CONT,POS PRESSURE W/FULL FIRE
FIGHTING CLOTHING
Unusual Fire/Explosion Hazard:NONE KNOWN
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB ANY SPILLED MATERIAL & FLUSH RESIDUE
WITH WATER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE SPECIFIED
Ventilation:GENERAL MECHANICAL
Protective Gloves:NONE SPECIFIED
Eye Protection:NONE SPECIFIED
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:612F,340C
Spec Gravity:1.05
Solubility in Water:IMMISCIBLE
Appearance and Odor:PLASTIC TUBE CONTAINING GREEN LIQ W/GLASS CAPSULE.
Percent Volatiles by Volume:<0.1
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIC
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE
==================== Disposal Considerations ====================
Waste Disposal Methods:PLACE IN CONTAINERS SUITABLE FOR SHIPMENT TO
DISPOSAL AREA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|