===================== Product Identification =====================
MSDS NAME:DIESEL 2, PRODUCT CODE 072720-00787
NIIN:00-286-5294
MSDS Number: BGXGY
=== Responsible Party ===
Company:EXXON COMPANY, USA, A DIV OF EXXON CORP.
Address:800 BELL ST
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Info Phone Num:713-656-5949
Emergency Phone Num:713-656-3424/2443 (MEDICAL)
CAGE:DO850
=== Contractor Identification ===
Company:EXXON COMPANY U.S.A.
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Phone:713-656-5949 / 713-656-3424
CAGE:29700
Company:EXXON COMPANY, USA, A DIV OF EXXON CORP.
Address:800 BELL ST
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Phone:713-656-5949 FAX: 713-656-3631
CAGE:DO850
============= Composition/Information on Ingredients =============
Name:PETROLEUM MID-DISTILLATE (DIESEL MARINE FUEL)
CAS:68476-34-6
Fraction by Wt: 100%
Other REC Limits:100 PPM/8 HRS. DAY
OSHA PEL:5 MG/M3 AS OIL MIST
ACGIH TLV:5 MG/M3 AS OIL MIST
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 (RATS) ORAL >5,000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:EYE CONTACT MAY CAUSE IRRITATION.
PROLONGED OR REPEATED SKIN CONTACT WITH THIS PRODUCT TENDS TO
REMOVE SKIN OILS, POSSIBLY LEADING TO IRRITATION AND DERMATITIS.
Explanation of Carcinogenicity:LONG-TERM REPEATED EXPOSURE MAY CAUSE
SKIN CANCER
Effects of Overexposure:PROLONGED OR REPEATED LIQUID CONTACT WITH THE
SKIN WILL DRY AND DEFAT THE SKIN, LEADING TO POSSIBLE IRRITATION
AND DERMATITIS. HIGH VAPOR CONCENTRATIONS ARE IRRITATING TO THE
EYES AND THE RESPIRATORY TRACT, AND MAY CAUSE HEADACHES,
DIZZINESS, ANESTHESIA, DROWSINESS, UNCONSCIOUSNESS, AND OTHER CNS
EFFECTS.
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGREVATE AN
EXISTING DERMATITIS.
======================= First Aid Measures =======================
Eyes: FLUSH WITH CLEAR WATER FOR 15 MINUTES OR UNTIL
IRRITATION SUBSIDES. CALL A PHYSICIAN IF NECESSARY. SKIN: REMOVE
CONTAMINATED CLOTHING AND WASH SKIN THOROUGHLY WITH SOAP AND WATER.
IF PRODUCT IS INJECTED INTO OR UNDER THE SKIN, IMMEDIATELY HAVE A
PHYSICIAN EVALUATE AS A SURGICAL EMERGENCY. INHALATION: USUALLY NOT
A PROBLEM. IF NECESSARY, REMOVE TO FRESH AIR.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:140F,60C
Autoignition Temp:Autoignition Temp Text:>400F
Lower Limits:0.9
Upper Limits:7
Extinguishing Media:FOAM, WATER SPRAY (FOG), DRY CHEMICAL, CARBON
DIOXIDE AND VAPORIZING LIQUID TYPE EXTINGUISHING AGENTS.
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE, BUT USE TO COOL FIRE
EXPOSED CONTAINERS. USE WATER SPRAY TO DISPERSE VAPORS. WEAR SELF-
CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:THIS LIQUID IS VOLATILE AND GIVES OFF
INVISIBLE VAPORS. EITHER THE LIQUID OR VAPOR MAY SETTLE IN LOW
AREAS OR TRAVEL SOME DISTANCE ALONG THE GROUND.
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. RECOVER FREE
PRODUCT. ADD SAND, EARTH, OR OTHER ABSORBENT TO SPILL AREA.
VENTILATE CONFINED SPACES. KEEP PREDUCT OUT OF SEWERS AND
WATERCOURSES. ADVISE AUTHORITIES IF P RODUCT MAY ENTER SEWERS,
WATERCOURSES OR LAND AREA
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP PRODUCT AWAY FROM IGNITION
SOURCES, SUCH AS HEAT, SPARKS, PILOT LIGHTS, STATIC ELECTRICITY AND
OPEN FLAME.
Other Precautions:THIS LIQUID IS VOLATILE AND GIVE OFF INVISIBLE
VAPORS. EITHER THE LIQUID OR VAPORS MAY SETTLE IN LOW AREAS OR
TRAVEL SOME DISTANCES ALONG THE GROUND. EMPTY CONTAINERS RETAIN
RESIDUE AND CAN BE DANGERO US.KEEP CONTAINERS CLOSED IF NOT IN USE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE SUPPLIED-AIR RESPIRATORY PROTECTION IN
CONFINED OR ENCLOSED SPACES, IF NEEDED.
Ventilation:USE ONY WITH VENTILATION SUFFICIENT TO PREVENT EXCEEDING
RECOMMENDED EXPOSURE LIMIT OR BUILDUP OF EXPLOSIVE CONCENTRAT'N
Protective Gloves:CHEMICAL-RESISTANT GLOVES, IF NEEDED.
Eye Protection:SPLASH GOGGLES OR FACE SHIELD.
Other Protective Equipment:CHEMICAL-RESISTANT APRON OR OTHER OMPERVIOUS
CLOTHING, IF NEEDED.
Work Hygienic Practices:MINIMIZE BREATHING VAPOR, MIST OR FUMES. AVOID
PROLONGED CONTACT WITH THE SKIN. CLEANSE THOROUGHLY AFTER CONTACT.
Supplemental Safety and Health
PRODUCT IS READILY REMOVED FROM SKIN BY WATERLESS HAND CLEANERS
FOLLOWED BY WASHING THOROUGHLY WITH SOAP AND WATER. REMOVE
CONTAMINATED SHOES AND THOROUGHLY CLEAN BEFORE RE-USE; DISCARD IF
OIL-SOAKED . NO TOXIC CHEMICAL IS PRESENT GREATER THAN 1% OR 0.1%
(CARCINOGEN).
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:320F,160C
Melt/Freeze Pt:M.P/F.P Text:-0F,-18C
Vapor Pres:< 1 MM HG
Vapor Density:>5
Spec Gravity:0.86
pH:@7
Viscosity:2.7 CST @ 40C
Evaporation Rate & Reference:0.02 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUID, YELLOW COLOR. FAINT PETROLEUM
HYDROCARBON ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS SUCH AS LIQUID CHLORINE, CONCENTRATED OXYGEN, SODIUM
HYPOCHLORITE, CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN
FLAMES.
Hazardous Decomposition Products:FUMES, SMOKE, CARBON MONOXIDE,
ALDEHYDES AND OTHER DECOMPOSITION PRODUCTS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|