===================== Product Identification =====================
MSDS NAME:WHITE LIGHTNIN'
NIIN:00N010663
MSDS Number: BHVGL
=== Responsible Party ===
Company:MONROE FLUID TECHNOLOGY,INC.
Address:36 DRAFFIN ROAD
Box:810
City:HILTON
State:NY
ZIP:14468
Info Phone Num:716-392-3434
Emergency Phone Num:716-392-3434
CAGE:60030
=== Contractor Identification ===
Company:MONROE FLUID TECHNOLOGY
Address:36 DRAFFIN RD
Box:810
City:HILTON
State:NY
ZIP:14468-9708
Country:US
Phone:800-828-8351
CAGE:60030
============= Composition/Information on Ingredients =============
Name:1,4-DIOXANE (DIETHYLENE DIOXIDE) (SARA III)
CAS:123-91-1
RTECS #:JG8225000
Fraction by Wt: 1%
Other REC Limits:N/K
OSHA PEL:S, 100 PPM
ACGIH TLV:S, 25 PPM; 9293
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Name:SEC-BUTYL ALCOHOL (SARA III)
CAS:78-92-2
RTECS #:EO1750000
Fraction by Wt: 1%
Other REC Limits:N/K
OSHA PEL:150 PPM
ACGIH TLV:100 PPM; 9293
Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 96%
Other REC Limits:N/K
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1
Name:GLYCOL METHYLENE ETHER
CAS:646-06-0
RTECS #:JH6760000
Fraction by Wt: 1%
Other REC Limits:N/K
OSHA PEL:N/K
ACGIH TLV:N/K
Name:FIRST AID:CONSULT LITERATURE.HANDLING/STORAGE
PRECAUTIONS:APPARATUS AND AN OBSERVER FOR ASSISTANCE.
RTECS #:9999999ZZ
Other REC Limits:N/K
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:SEE SUPP DATA
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SYSTEMATIC:MAY INCREASE MYOCARDIAL
IRRITABILITY.CHRONIC SKIN EXPOSURE MAY CAUSE DEFATTING TYPE OF
DERMATITIS.
Explanation of Carcinogenicity:DIETHYLENE ETHER:INAD EVID FOR CARCIN IN
HUM;SUFF EVID IN ANIM (IARC,1987).SUSP HUM CARCIN/KNOWN ANIM CARCIN
(NTP,1985).
Effects of Overexposure:EYES:CONJUNCT,MILD IRRIT.NO CORNEAL INJURY
LIKELY.SKIN:MILD IRRIT,CHRONIC EXPOS MAY CAUSE DEFATTING TYPE OF
DERMAT.NOT LIKELY TO BE ABSORBED IN ACUTELY TOXIC AMTS.VERY LOW
TOXICITY.INGEST:VERY LOW TOX ICITY.RXN SIMILAR TO PETRO/PETRO-LIKE
SOLV.INHAL:ANESTHETIC EFFECTS NEAR 1000 PPM.NARCOTIC EFFECT MAY
OCCUR.
Medical Cond Aggravated by Exposure:SYSTEMATIC:MAY INCREASE MYOCARDIAL
IRRITABILITY.
======================= First Aid Measures =======================
Eyes:IRRIGATE IMMED W/ WATER FOR AT LEAST 15 MIN.MD-STAIN FOR
CORNEAL INJURY EVID.SKIN:WASH OFF IN FLOWING WATER OR
SHOWER.MD-TREAT AS ANY CONTACT DERMAT.INGEST:DO NOT INDUCE
VOMIT.CALL MD &/OR TRANSP ORT TO MED FACILITY.MD-WEIGH CHEM
PNEUMDANGER AGAINST TOXICITY WHEN EMPTYING STOM.IF LAVAGE
PERFORMED,SUGGEST ENDOTRACHEAL &/OR ESOPHAGOSCOPIC
CONTROL.INHAL:REMOVE TO FRESH AIR.IF RESP (SEE SUPP)
===================== Fire Fighting Measures =====================
Flash Point:NONE
Lower Limits:15% @ 25C
Upper Limits:7.5% @ 25C
Extinguishing Media:WATER FOG,DRY CHEMICALS OR CARBON DIOXIDE.
Fire Fighting Procedures:WEAR PRESSURE DEMAND SCBA AND FULL PROTECTIVE
EQUIPMENT .NOT CONSIDERED A FLAMMABLE LIQUID HAZARD UNDER AMBIENT
TEMPERATURE USE CONDITIONS.
Unusual Fire/Explosion Hazard:N/K .HAZARDOUS DECOMPOSITION
PRODUCTS:HYDROGEN CHLORIDE & VERY SMALL AMOUNTS OF PHOSGENE &
CHLORINE.
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL-WIPE OR SOAK UP W/ ABSORB
(SAWDUST,VERMICULITE),SWEEP INTO CLOSED
CONTRS.LARGE-EVACUATE,PROVIDE MAX VENT.DIKE TO CONTAIN.RECOVER
SPILLED MATL ON ABSORB & PLACE IN CLOSED CONTR.PREVENT CONTAM OF
GROUND & SURFACE WATER.DO NOT FLUSH INTO SEWERS.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:HANDLE W/ CARE.STORE IN COOL,DRY
PLACE.AVOID VAPORS-HEAVIER THAN AIR,WILL COLLECT IN LOW AREAS.DO
NOT ENTER AREAS W/OUT SPECIAL BREATHING (SEE ING 5)
Other Precautions:NO SMOKING IN AREA OF USE.DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING,OPEN FLAMES OR HOT SURFACES.HEAT AND/OR UV
RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:N/K
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NO SPECIAL PROTECTIVE CLOTHING NEEDED.
Work Hygienic Practices:WASH CLOTHING BEFORE REUSE.
Supplemental Safety and Health
FL PT METH:TOC,TCC,COC.LD50-LC50 MIX:LD50 LAB ANIMALS INGEST 8.6-15.0
G/KG.LD50 RABBIT SKIN >15 G/KG 24 HR EXPOS.FIRST AID
PROC:STOPS,GIVE RESUSCITATION.GIVE O*2.CALL MD &/OR TRANSPORT TO
MED FACILITY .MD-BRONCHODILATORS,EXPECTORANTS & ANTI-TUSSIVES MAY
HELP.SYSTEMATIC:AVOID EPINEPHRINE,SIMILAR ACTING DRUGS.(SEE ING 5)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:165F,74C
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:100 MMHG
Vapor Density:4.55,AIR=1
Spec Gravity:1.314 (WATER=1)
Evaporation Rate & Reference:N/K
Solubility in Water:0.07/100G @ 25C,77F
Appearance and Odor:COLORLESS LIQUID
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
WATER-SLOW HYDROLYSIS PRODUCES CORROSIVE ACID.
Stability Condition to Avoid:AVOID OPEN FLAMES,WELDING ARCS OR OTHER
HIGH TEMPERATURE SOURCES WHICH INDUCE THERMAL DECOMPOSITION.
Hazardous Decomposition Products:HYDROGEN CHLORIDE & VERY SMALL AMOUNTS
OF PHOSGENE & CHLORINE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|