===================== Product Identification =====================
MSDS NAME:BLACK 8507
NIIN:00N010783
MSDS Number: BHVJJ
=== Responsible Party ===
Company:MARKEM CORPORATION
Address:150 CONGRESS STREET
City:KEENE
State:NH
ZIP:03431
Info Phone Num:603-352-1130
Emergency Phone Num:603-352-1130
CAGE:38360
=== Contractor Identification ===
Company:MARKEM CORPORATION
Address:150 CONGRESS STREET
Box:City:KEENE
State:NH
ZIP:03431
Country:US
Phone:603-352-1130
CAGE:38360
============= Composition/Information on Ingredients =============
Name:DIETHYLENE GLYCOL MONOBUTYL ETHER ACETATE
CAS:124-17-4
RTECS #:KJ9275000
Fraction by Wt: 10-25%
Other REC Limits:N/K
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
OVEREXPOSURE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:MODERATE
IRRITATION,REDNESS,TEARING.SKIN:SLIGHT
IRRITATION.INGESTION:IRRITATION,NAUSEA,VOMITING,DIARRHEA.INHALATION
:IRRITATION,WEAKNESS,DIZZINESS,FATIGUE,NAUSEA,HEADACHE.
Medical Cond Aggravated by Exposure:N/K
======================= First Aid Measures =======================
Eyes:FLUSH WITH WATER FOR AT LEAST 15 MINUTES.CALL A
PHYSICIAN IMMEDIATELY.SKIN:WASH W/ SOAP & WATER.LAUNDER CONTAM
CLOTHING BEFORE REUSE.GET MEDICAL ATTENTION.INGESTION:IF
CONSCIOUS,GIVE TWO GLASSES OF WATER & INDUCE VOMITING.GET MEDICAL
ATTENTION IMMEDIATELY.INHALATION:REMOVE TO FRESH AIR.BEGIN
RESUSCITATION.GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:237F,113.89C
Extinguishing Media:DRY CHEMICAL,CO*2,ALCOHOL FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL
ALONG GROUND & MAY BE IGNITED AT DISTANT LOCATIONS.HAZARDOUS
DECOMPOSITION PRODUCTS:CO,CO*2.
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION.ABSORB
SPILLED MATERIAL WITH VERMICULITE OR FLOOR ABSORBENT.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:N/K
Other Precautions:N/K
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW EXPOSURE OF CONCERN .
Protective Gloves:RUBBER (LATEX OR NEOPRENE).
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:N/K
Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
ROUTES OF ENTRY:INGEST:YES .
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:N/K
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:VERY LOW
Vapor Density:N/K
Spec Gravity:N/K
Evaporation Rate & Reference:VERY SLOW
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK INK,MILD ODOR.
Percent Volatiles by Volume:<1
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES,STRONG MINERAL ACIDS.
Stability Condition to Avoid:HEAT AND FLAME.
Hazardous Decomposition Products:CO,CO*2.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISP MUST BE IN ACCORDANCE W/ FEDERAL,STATE &
LOCAL REGS .UNDER RCRA,IT IS RESPONSIBILITY OF WASTE GENERATOR TO
DETERMINE IF WASTE MEETS FEDERAL,STATE HAZ WASTE CRITERIA
(USES,MIXS,PROCESSES,ETC MAY RENDER MATL HAZ).CONSULT ATHRTY FOR
INFO.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|