232376 E. Pacifica Place Rancho Dominguez, CA 90220 (800) 675-1118 www.alliedhightech.com
MATERIAL SAFETY DATA SHEET
NAME OF PRODUCT
SECTION 1:
PRODUCT NAME: ALLIED ITEM NUMBER(S):
Aluminum Oxide Abrasive Belts 50-10460-50-10485
CHEMICAL NAME or PRODUCT TYPE:
Aluminum Oxide & Resin Binder on cloth
SECTION 2: COMPOSITION
OSHA
PERMISSIVE
REG EXPOSURE ACGIH CARCIN.
CAS #
Chemical Name Common Name (Y/N) LIMIT TLV (Y/N)
15mg/M 3 10 mg/M3
Aluminum Oxide Y 1344-28-1 N
Cryolite Y 15096-52-3 N/A N/A N
Potassium Fluoroborate Y 14075-53-7 N/A N/A N
Cured Phenolic Resin Y 60304-36-1 N/A N/A N
Calcium Oxide Y 1305-78-8 2mg/M3 N/A N
Zinc Stearate Y 557-05-01 N/A N/A N
HMIS CODE:
HEALTH FLAMMABILITY REACTIVITY
1 0 0
Ingredients are listed on the TSCA Inventory of Chemical Substances. Those not identified are non-hazardous.
PHYSICAL & CHEMICAL DATA
SECTION 3:
MELTING POINT:
BOILING POINT: SPECIFIC GRAVITY:
N/A N/A N/A
VAPOR DENSITY:
VAPORPRESSURE: % VOLATILE by VOL./WGT:
N/A N/A N/A
SOLUBILITY in WATER: SOLUBILITY in ALCOHOL:
EVAPORATION RATE:
N/A N/A N/A
APPEARANCE and ODOR:
SOLUBILITY in OTHER SOLVENT:
N/A Paper, cloth or fiber coated w/abrasive material
FIRE & EXPLOSION HAZARD DATA
SECTION 4:
FLAMMABLE LIMITS:
FLASH POINT: METHODUSED:
N/A N/A LEL: N/A N/A
UEL:
EXTINGUISHING MEDIA:
Any proper fire-fighting material can be used
SPECIAL FIRE FIGHTING PROCEDURES:
Use respiratory protection - backings and resin binders will burn and/or decompose
EXPLOSION POTENTIAL: N/A
HEALTH, FIRST AID, & MEDICAL DATA
SECTION 5:
ACUTE and CHRONIC HEALTH EFFECTS FIRST AID and MEDICAL INFORMATION
ROUTE(S) of ENTRY
Acute - may cause coughing, shortness of breath. Remove to fresh air. Give artificial respiration as
INHALATION:
Chronic - may affect breathing capacity. needed. Obtain medical assistance if needed.
No known adverse effects Obtain medical assistance if needed.
INGESTION:
but ingestion is not recommended.
SKIN Not absorbed through skin; Obtain medical assistance if needed.
may cause abrasions.
CONTACT/ABSORPTION:
Wash with large amounts of water. Obtain
Dust may irritate eyes.
EYE:
medical assistance if needed.
During use on some materials, elevated sound levels
OTHER POTENTIAL
may be created which affect hearing
HEALTH RISK:
LEGEND: NAIF = NoApplicable Information Found
Applicable
118 & 119
OFFICE CODE: MSDS.P65:
N/A = Not
2376 E. Pacifica Place 鈥? Rancho Dominguez, CA 90220 鈥? (800) 675-1118 鈥? ww.alliedhightech.com
Page 2 of 2: Aluminum Oxide Abrasive Belts
CORROSIVITY & REACTIVITY DATA
SECTION 6:
x x
STABILITY: UNSTABLE STABLE POLYMERIZATION: MAY OCCUR WILL NOT OCCUR
INCOMPATIBILITY (MATERIALS to AVOID):
N/A
DECOMPOSITION PRODUCTS:
In use, dust and decomposing resin fumes are generated; in most cases, the material removed from the
work piece will be significantly greater than the coated abrasive product components.
CONDITIONS to be AVOIDED:
None
STORAGE, HANDLING, & USAGE PROCEDURES
SECTION 7:
NORMAL STORAGE and HANDLING:
Handle with adequate ventilation.
OSHA 29 CFR 1910.94 (Ventilation) and OSHA 29 CFR 1910.1000 (Air Contaminates).
NORMAL USE:
Handle with adequate ventilation.
OSHA 29 CFR 1910.94 (Ventilation) and OSHA 29 CFR 1910.1000 (Air Contaminates).
STEPS to be TAKEN in case of LEAKS or SPILLS:
Normal Clean-up procedures. Vacuum dust.
WASTE DISPOSAL METHOD:
Standard landfill methods consistent with
all Local, State and Federal regulations.
PERSONAL PROTECTION INFORMATION
SECTION 8:
RESPIRATORY PROTECTION (SPECIFY TYPE):
As needed, approved dust respirator (OSHA 29 CFR 1910.134)
LOCAL: Recommended
{ MECHANICAL (GENERAL):
VENTILATION Recommended
OTHER: NAIF
Leather gloves as desired by user.
PROTECTIVE GLOVES:
Recommended OSHA 29 CFR 1910.133
EYEPROTECTION:
Hearing protection OSHA 29 CFR 1910.215
OTHEREQUIPMENT:
SPECIAL PRECAUTIONS; EMERGENCY OVERVIEW; NOTES
SECTION 9:
Slight formaldehyde or phenolic resin odor may be released on occasion during storage.
DISCLAIMER: The above information and recommendations are believed accurate and reliable. Because it is not possible to
anticipate all conditions of use, additional safety precautions may be required. ALLIED HIGH TECH PRODUCTS, INC. makes no
warranty, either express or implied, as to its accuracy or completeness and none is made as to the fitness of this material for any
purpose. The manufacturer/distributor shall not be liable for damages to person or property resulting from its use. Nothing
herein shall be construed as a recommendation for use in violation of any patent.
Kim Dermit, July, 2002 Produced by Allied High Tech Products, Inc. in the USA
FORM PREPARED BY:
|