B-12 Chemtool Carburetor Cleaner Fuel Treatment MSDS No. 002
Date of Preparation: 10-29-99 Revision: 11-29-05
Section 1 - Chemical Product and Company Identification
Product/Chemical Name: B-12 Chemtool Carburetor Cleaner Fuel Treatment
Part Number: 0112 (Blend 1AC)
CAS Number: Not Applicable to Mixtures
General Use: Automotive Product
Manufacturer: Berryman Products, Inc., 3800 E. Randol Mill Rd., Arlington, TX 76011-5434
Phone: 1-800-433-1704, Emergency phone number: 1-800-535-5053
Emergency Overview


Section 2 - Composition / Information on Ingredients
Ingredient Name CAS Number % wt or
% vol
Mixed Xylenes 1330-20-7 65-75
N-Propanol 71-23-8 15-20
2-Butoxyethanol 111-76-2 5-15
Ethyl Benzene 100-41-4 5-15

Trace Impurities:

OSHA PEL ACGIH TLV NIOSH REL NIOSH
Ingredient TWA STEL TWA STEL TWA STEL IDLH
100 none estab. 100 150 none estab. none estab. none estab.
Mixed Xylenes
200 none estab. 200 250 none estab. none estab. none estab.
N-Propanol
50 none estab. 20 none estab. none estab. none estab. none estab.
2-Butoxyethanol
100 none estab. 100 125 none estab. none estab. none estab.
Ethyl Benzene
Section 3 - Physical and Chemical Properties
Physical State: Liquid Vapor Pressure: 9 mm Hg at 68 掳F (major component)
Boiling Point: 207-378 oF
Appearance and Odor: Clear, colorless, aromatic
Vapor Density (Air=1): Heavier than air Refractive Index: 1.4660
Density: 7.19 lbs/gal % Volatile: 100
Evaporation Rate: Slower then ether
Specific Gravity (H2O=1, at 4 掳C): 0.861

Section 4 - Fire-Fighting Measures
NFPA
Flash Point: 68 掳F
Flash Point Method: CC
3
LEL: 1.1% v/v (Major component)
0
2
Flammability Classification: Class IB
鈥?
Extinguishing Media: Carbon dioxide, foam, dry chemicals
Unusual Fire or Explosion Hazards: Flammable liquid
Fire-Fighting Instructions: Do not release runoff from fire control methods to sewers or waterways.
Fire-Fighting Equipment: Wear self-contained breathing apparatus pressure demand, MSNA/OSHA (approved or equivalent)
and full protective gear. Use water spray to keep fire-exposed containers cool.
Section 5 - Stability and Reactivity
Stability: B-12 Chemtool Carburetor Cleaner Fuel Treatment is stable at room temperature in closed containers under normal
storage and handling conditions.
Polymerization: Hazardous polymerization cannot occur.
Chemical Incompatibilities and Conditions to Avoid: Isolate from oxidizers, heat, sparks, electric equipment and open flame.
Hazardous Decomposition Products: Thermal oxidative decomposition of B-12 Chemtool Carburetor Cleaner Fuel Treatment
can produce carbon monoxide and carbon dioxide.
MSDS No. 002 B-12 Chemtool Carburetor Cleaner Fuel Treatment Revision: 11-29-05
Section 6 - Health Hazard Information
Potential Health Effects
Primary Entry Routes: Skin, dermal, inhalation and ingestion.
Target Organs: Eyes, skin, respiratory system, CNS, GI tract, blood, liver and kidneys.
Acute Effects
Carcinogenicity: IARC, NTP, and OSHA do not list B-12 Chemtool Carburetor Cleaner Fuel Treatment as a carcinogen.
Medical Conditions Aggravated by Long-Term Exposure:
Chronic Effects: Mazy affect liver, kidneys, blood, GI tract or central nervous system. Can cause nervous system depression.

Emergency and First Aid Procedures
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. Get medical attention immediately.
Eye Contact: Immediately flush eyes with plenty of water. Get medical attention, if irritation persists.
Skin Contact: Immediately wash skin with soap and plenty of water. Remove contaminated clothing. Get medical attention if
symptoms occur. Wash clothing before reuse.
Ingestion: GET MEDICAL ATTENTION IMMEDIATELY. Do not induce vomiting.
After first aid, get appropriate in-plant, paramedic, or community medical support.
Section 7 - Spill, Leak, and Disposal Procedures
Spill /Leak Procedures: Eliminate all sources of ignition. Stop spill at source. Wear appropriate personal protective equipment
(Sec. 8). Contain the spill to facilitate clean up with absorbent. Use non-sparking tools and equipment. Transfer to disposal
containers.
Containment: For large spills, dike far ahead of liquid spill for later disposal. Do not release into sewers or waterways.
Regulatory Requirements: Follow applicable OSHA regulations (29 CFR 1910.120).
Disposal: Contact your supplier or a licensed contractor for detailed recommendations. Follow applicable Federal, state and
local regulations.
Section 8 - Exposure Controls / Personal Protection
Ventilation: Provide general or local exhaust ventilation systems to maintain airborne concentrations below OSHA PELs
(Sec. 2). Local exhaust ventilation is preferred because it prevents contaminant dispersion into the work area by controlling it at
its source.
Respiratory Protection: Seek professional advice prior to respirator selection and use. Follow OSHA respirator regulations
(29 CFR 1910.134) and, if necessary, wear a MSHA/NIOSH-approved respirator. Select respirator based on its suitability to
provide adequate worker protection for given working conditions, level of airborne contamination, and presence of sufficient
oxygen. For emergency or nonroutine operations (cleaning spills, reactor vessels, or storage tanks), wear an SCBA.
Warning! Air-purifying respirators do not protect workers in oxygen-deficient atmospheres. If respirators are used, OSHA
requires a written respiratory protection program that includes at least: medical certification, training, fit-testing, periodic
environmental monitoring, maintenance, inspection, cleaning, and convenient, sanitary storage areas.
Protective Clothing/Equipment: Wear chemically protective gloves, boots, aprons, and gauntlets to prevent prolonged or
repeated skin contact. Wear protective eyeglasses or chemical safety goggles, per OSHA eye- and face-protection regulations
(29 CFR 1910.133). Contact lenses are not eye protective devices. Appropriate eye protection must be worn instead of, or in
conjunction with contact lenses.
Safety Stations: Make emergency eyewash stations, safety/quick-drench showers, and washing facilities available in work area.
Contaminated Equipment: Separate contaminated work clothes from street clothes. Launder before reuse. Remove this
material from your shoes and clean personal protective equipment.
Comments: Never eat, drink, or smoke in work areas. Practice good personal hygiene after using this material, especially before
eating, drinking, smoking, using the toilet, or applying cosmetics.
Section 9 - Special Precautions and Comments
Handling Precautions: Avoid prolonged breathing of vapor and contact with eyes, skin and clothing. Use in well ventilated
area. Wash thoroughly after handling.
Storage Requirements: Keep away from heat, sparks and flame. Keep container closed when not in use.
California Proposition 65: This product contains the following chemicals known to the state of California to cause cancer
and/or reproductive toxicity: None.

DOT Transportation Data (49 CFR 172.101):
Shipping Name: Consumer Hazard Class: ORM-D
Part Number(s): 0112
Commodity ID No.: N/A
Packing Group: N/A

Page 2 of 3
Revision: 11-29-05 B-12 Chemtool Carburetor Cleaner Fuel Treatment MSDS No. 002
SARA Title III Section 313 Supplier Notification:
This product contains the following toxic chemicals subject to the reporting requirements of Section 313 of the emergency
Planning & Community Right-To-Know-Act of 1986 & of 40CFR 372: Mixed Xylenes and Ethyl Benzene

Prepared By: Alicia L. Reed

Disclaimer: All information appearing herein is based upon data obtained from manufacturers and/or recognized technical sources. While the
information is believed to be accurate, we make no representations as to its accuracy or sufficiency. Conditions of use are beyond our control,
therefore users are responsible for verifying the data under their own operating conditions to determine whether the product is suitable for their
particular purposes and they assume all risks of their use, handling and disposal of the product. Users also assume all risks in regards to the
publications of use of, or reliance upon information contained herein. This information relates only to the product designated herein, and does not
relate to its use in combination with any other material or process.




Page 3 of 3

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
arkema-inc_com---936.asp 68425-15-0
arkema-inc_com---937.asp 68425-15-0
arkema-inc_com---941.asp 68555-98-6
arkema-inc_com---942.asp 68555-98-6
arkema-inc_com---943.asp 68555-98-6 1344-95-2
arkema-inc_com---944.asp 68555-98-6
arkema-inc_com---945.asp 68937-96-2
arkema-inc_com---946.asp 57-11-4 60303-68-6
arkema-inc_com---961.asp 7732-18-5 60-24-2
arkema-inc_com---965.asp 111-48-8
arkema-inc_com---970.asp 107-03-9
arkema-inc_com---971.asp 75-33-2
arkema-inc_com---977.asp 111-88-6
arkema-inc_com---983.asp 25322-69-4 112-55-0
arkema-inc_com---995.asp 14970-87-7
arkema-inc_com---ap07701.asp N/A
arkema-inc_com---ap10080.asp 354-33-6 75-45-6 74-98-6
arkema-inc_com---ap71119.asp 3622-84-2
arkema-inc_com---ap9120.asp 2273-43-0
arkema-inc_com---ap9330.asp 14808-60-7 7631-86-9
arkema-inc_com---ap9987.asp N/A
arkema-inc_com---lu120.asp 1338-23-4 107-41-5 78-93-3 7722-84-1
arkema-inc_com---org001029.asp 102-79-4
arkema-inc_com---org0119f.asp 121-44-8
arkema-inc_com---org0150.asp 100-37-8
arkema-inc_com---org7042.asp 102-79-4
avantigrout_com---productguide0507.asp N/A
berrymanproducts_com---0101_0105_0116_0155.asp 09-10-0 108-88-3 67-56-4 67-64-1 78-93-3 111-76-2 67-63-0 1330-20-7
berrymanproducts_com---0112.asp 10-29-9 1330-20-7 71-23-8 111-76-2 100-41-4
berrymanproducts_com---0113_0152_0117c_0120c.asp 12-31-0 67-64-1 108-88-3 67-56-1 78-93-3 111-76-2 67-63-0 1330-20-7 124-38-9
berrymanproducts_com---0216.asp 10-29-9 108-88-3 67-64-1 110-54-3 67-56-1 64742-47-8
berrymanproducts_com---0306.asp 10-29-9 67-63-0 111-76-2
berrymanproducts_com---0408_0416.asp 09-24-0 64475-85-0 11-29-0
berrymanproducts_com---0501_0505_0516_0532_0555.asp 10-29-9 8008-20-6
berrymanproducts_com---0512.asp 10-29-9 64742-94-5 91-20-3
berrymanproducts_com---0517.asp 02-03-0 68132-00-3 104-76-7 27247-96-7 91-20-3
berrymanproducts_com---0612_0665.asp 10-29-9 64475-85-0 124-38-9
berrymanproducts_com---0712.asp 09-28-0 6422-86-2 111-76-2
berrymanproducts_com---0801_0805_0832_0855.asp 02-13-0
berrymanproducts_com---0807.asp 10-29-9 108-88-3 124-38-9
berrymanproducts_com---0808.asp 10-29-9 67-63-0
berrymanproducts_com---0816.asp 09-08-0 64-17-5 111-76-2 68476-85-7
berrymanproducts_com---0818.asp 02-13-0
berrymanproducts_com---0901_0905.asp 10-29-9 75-09-2 1330-20-7 10588-01-9 100-41-4
berrymanproducts_com---1112_1115_1165.asp 10-29-9 1330-20-7 64475-85-0 100-41-4 71-23-8
berrymanproducts_com---1116_b-33m.asp 10-29-9 8008-20-6 68132-00-3 102-71-6 124-38-9
berrymanproducts_com---1116_wbed.asp 05-16-0 7727-37-9
berrymanproducts_com---1120_1126.asp 11-26-0 1330-20-7 111-76-2 100-41-4 78-93-3 67-64-1 67-56-1
berrymanproducts_com---1301_1304_1305_1308_1316_1332_1355.asp 10-29-9
berrymanproducts_com---1401_1405_1455.asp 10-29-9 127-18-4 75-09-2 68410-97-9

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC