Biomolecules for research MATERIAL SAFETY DATA SHEET



Section 1 : Substance Identification

MMP Inhibitor Profiling Kit, Fluorimetric
Name:

Catalog Number: AK-016


Company Identification: BIOMOL International L.P.
5120 Butler Pike
Plymouth Meeting PA 19462-1202 USA
(610) 941-0430 (9am-5pm ET)




Section 2 : Components

Vial # Name: Contents: Quantity

SE180-9090 MMP-1 Enzyme 30.6 U/碌l 2000 U
(human recombinant)

SE237-9090 MMP-2 Enzyme 3.7 U/碌l 150 U
(human recombinant)

SE109-9090 MMP-3 Enzyme 10 U/碌l 300 U
(human recombinant)

SE181-9090 MMP-7 Enzyme 4.5 U/碌l 150 U
(human recombinant)

SE255-9090 MMP-8 Enzyme 9.2 U/碌l 200 U
(human recombinant)

SE244-9090 MMP-9 Enzyme 2.68 U/碌l 130 U
(human recombinant)

SE329-9090 MMP-10 Enzyme 5 U/碌l 150 U
(human recombinant)
SE138-9090 MMP-12 Enzyme 10 U/碌l 140 U
(human recombinant)

SE246-9090 MMP-13 Enzyme 3.45 U/碌l 180 U
(human recombinant)

SE259-9090 MMP-14 Enzyme 12 U/碌l 300 U
(human recombinant)

OmniMMPTM fluorescent substrate
P126-9090 400 碌M in DMSO 200碌l

P127-9090 Calibration Standard 40 碌M in DMSO 50 碌l
(OmniMMP fluorescent control peptide)

PI115-9090 NNGH 1.3 mM in DMSO 30碌l
(inhibitor)

KI-175 Assay Buffer 50 mM HEPES, 10 mM CaCl2, 2 x 20ml
0.05% Brij-35, pH 7.5

AK016 Instruction Booklet 1 booklet

KI-110 White 96-Well Plate White 陆 Volume 96-Well plate 1 plate




Section 3 : Health Hazards


Please be advised that the physical, chemical and toxicological properties of many of these components have not
yet been fully investigated. Exposure to reagents used in this kit has been shown to cause irritation of the skin. It
is therefore advised that all laboratory personnel handling this product follow standard laboratory safety
procedures. It is recommended that personnel wear safety goggles, gloves, and protective clothing at all times,
and avoid direct contact with the reagents supplied in this kit.




Section 4 : First Aid


Eye Contact: Check for and remove contact lenses. Flush eyes with running water for at least 15
minutes separating eyelids. Seek medical attention immediately
Skin Contact: Wash with soap and water for 15 minutes. Remove contaminated clothing and shoes.
If irritation or discomfort develops, seek medical attention.
Inhalation: Remove from exposure. If breathing is difficult, administer oxygen. If breathing stops,
administer artificial respiration. Seek medical attention if patient feels unwell or develops any
respiratory symptoms. Provide chemical label and MSDS if possible.
Ingestion: Remove dentures and clear mouth. If person is conscious, rinse mouth with water. Call
physician or poison control immediately. Provide chemical label and MSDS information if
possible.
Section 5 : Fire / Flammability Information

None of the components of this kit pose a significant risk in case of fire. Fire fighting media should be
selected to suit other materials involved in the fire. Under fire conditions, hazardous decomposition
products such as carbon monoxide, carbon dioxide, nitrogen oxides and others may be produced. It is
recommended that firefighters wear protective gear and self contained breathing apparatus to limit
exposure.




Section 6 : Spill or Leak Procedures.


Cleanup Procedures: Wearing appropriate protective gear as outlined under 鈥淧rotective equipment鈥?
wipe up spill area and rinse residue down the drain with plenty of water. Wash spill site with soap
and water.
Waste Disposal Method: Dilute waste solutions and reagents with water and dispose of in accordance
with federal, state, and local regulations.



Section 7 : Storage and Handling Precautions

Protective Equipment: For spill clean up, wear suitable protective clothing, chemical resistant rubber
gloves, protective shoes, and chemical safety goggles.
Storage and Handling: The components of this kit should be stored 鈥?70掳C with the exception of the
assay buffer which can be stored at 4掳C and the 96-well plate and instruction booklet which can be
stored at room temperature. All components should be kept in tightly closed containers. This
product should be handled only by qualified experienced professionals. Wash thoroughly after
handling the materials included in this kit.




Section 8 : Stability and Reactivity Data

Stability: This material is stable if stored as directed
Conditions to Avoid: None known
Incompatibles: Not available




Section 10 : Ecological Data

Ecotoxicological Information: None Available
The above information is believed to be correct but does not purport to be complete and should be used only as a guide. The burden of
safe use of this material rests entirely with the user.


Emergency Contact:

BIOMOL International L.P.
5120 Butler Pike
Plymouth Meeting, PA 19462 USA

(610) 941-0430



Last Revised : 2/27/07

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
ascentscientific_com---asc-036_msds.asp 140187-23-1
ascentscientific_com---asc-037_msds.asp 146-77-0
ascentscientific_com---asc-040_msds.asp N/A
ascentscientific_com---asc-042_msds.asp 104104-50-9
ascentscientific_com---asc-043_msds.asp N/A
ascentscientific_com---asc-045_msds.asp 06052-12-1 118876-58-7
ascentscientific_com---asc-046_msds.asp N/A
ascentscientific_com---asc-049_msds.asp 56-86-0
ascentscientific_com---asc-051_msds.asp 71-44-3
ascentscientific_com---asc-052_msds.asp 05052-10-3 6384-92-5
ascentscientific_com---asc-055_msds.asp 4368-28-9
ascentscientific_com---asc-058_msds.asp 66575-29-9
ascentscientific_com---asc-059_msds.asp 150145-89-4
ascentscientific_com---asc-065_msds.asp 129-56-6
ascentscientific_com---asc-066_msds.asp 52497-36-6
ascentscientific_com---asc-073_msds.asp 6989-98-6
ascentscientific_com---asc-078_msds.asp N/A
ascentscientific_com---asc-081_msds.asp 370-86-5
ascentscientific_com---asc-082_msds.asp N/A
ascentscientific_com---asc-084_msds.asp 83729-01-5
ascentscientific_com---asc-087_msds.asp 94421-68-8
ascentscientific_com---asc-088_msds.asp 06078-10-1 183232-66-8
ascentscientific_com---asc-095_msds.asp 198022-70-7
ascentscientific_com---asc-099_msds.asp 199875-69-9
ascentscientific_com---asc-100_msds.asp 58002-62-3
ascentscientific_com---asc-102_msds.asp 133059-99-1
ascentscientific_com---asc-108_msds.asp 40709-69-1
ascentscientific_com---asc-117_msds.asp 21306-56-9
ascentscientific_com---asc-130_msds.asp N/A
ascentscientific_com---asc-131_msds.asp 129453-61-8
ascentscientific_com---asc-133_msds.asp 59729-32-7
ascentscientific_com---asc-134_msds.asp 99614-02-5
ascentscientific_com---asc-140_msds.asp 152-11-4
ascentscientific_com---asc-141_msds.asp 520-36-5
ascentscientific_com---asc-142_msds.asp 75695-93-1
ascentscientific_com---asc-144_msds.asp 1952-15-4
ascentscientific_com---asc-148_msds.asp 19545-26-7
biomol-international_com---ak016.asp N/A
biomol-international_com---ak419.asp N/A
biomol-international_com---cn216.asp 150418-07-8
biomol-international_com---d110.asp 87134-87-0
biomol-international_com---ei143.asp 102649-79-6
biomol-international_com---ei217.asp 13492-01-8
biomol-international_com---ei246.asp 133052-90-1
biomol-international_com---g239.asp N/A
biomol-international_com---gz1031.asp N/A
biomol-international_com---no109.asp 83729-01-5
biomol-international_com---p210.asp N/A
biomol-international_com---p321.asp N/A
biomol-international_com---pe186.asp 59086-90-7

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC