DUPONT MERCK PHARMACEUTICAL CO -- KRYPTON 85
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BYGRZ
MSDS NAME: KRYPTON 85
Responsible Party
Name: DUPONT MERCK PHARMACEUTICAL CO
Address: 331 TREBLE COVE RD
City: N BILLERICA MA 01862
Info Phone: 800-362-2668
Emergency Phone Number: 508-667-9531;800-424-9300(CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DUPONT MERCK PHARMACEUTICAL CO
Address: 331 TREBLE COVE ROAD
City: BILLERICA MA 01862-5000
Phone: 617-482-9595/800-225-1572
Name: DUPONT MERCK PHARMACEUTICAL CO
Box: 80026
City: WILMINGTON DE 19880-0026
Phone: 302-992-4240
=======================================================
Ingredients
=======================================================
Cas: 7439-90-9
RTECS #: OC6772500
Name: KRYPTON
% Wt: 95-97
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Name: KRYPTON 85
% Wt: 3-5
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: INHALATION: INERT GAS. SIMPLE ASPHYXIANT. CHRONIC:
NONE SPECIFIED BY MANUFACTURER.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHALATION: REMOVE TO FRESH AIR IMMEDIATELY. IF BRATHING HAS
STOPPED, PERFORM ARTIFICIAL RESPIRATION. KEEP PERSON WARM AND QUIET. TREAT
SYMPTOMATICALLY AND SUPPORTIVELY. GET MEDICAL ATTENTION IMMEDIAT ELY. EYES:
FLUSH WITH POTABLE WATER FORAT LEAST 15 MINUTES. SEE MD (FP N). SKIN: FLUSH
WITH COPIOUS AMOUNTS OF WATER. SEE MD (FP N). INGESTION: CALL MD IMMEDIATELY
(FPN).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: NONE SPECIFIED BY MANUFACTURER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: OBSERVE ALL LOCAL, STATE & FEDERAL REGULATIONS WHEN
DISPOSING OF THIS SUBSTANCE.
Handling And Storage Precautions: OBSERVE ALL FEDERAL, STATE, AND LOCAL
REGULATIONS WHEN STORING THIS SUBSTANCE.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: NONE.
Lower Limits: NONE.
Upper Limits: NONE.
Extinguishing Media: NONE REQUIRED. USE MEDIA APPROPRIATE FOR ADJACENT
MATERIALS.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: KRYPTON IS A NON-FLAMMABLE GAS.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: PROVIDE GENERAL DILUTION VENTILATION.
Protective Gloves: NONE REQUIRED.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: NONE REQUIRED.
Work Hygienic Practices: NONE REQUIRED.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: -260F,-162C
M.P/F.P Text: -249F,-156C
Appearance and Odor: CLEAR, ODORLESS, COLORLESS, INERT GAS
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE EXPECTED.
Materials To Avoid: NONE EXPECTED.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: KRYPTON 85
Assigned IND: Y
Company: DUPONT MERCK PHARMACEUTICAL CO
PO Box: 80026
City: WILMINGTON DE
Zipcode: 19880-0026
Health Emergency Phone: 508-667-9531;800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 08/09/1995
Status Code: C
Label Date: 08/09/1995
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: None
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE: INHALATION: INERT GAS. SIMPLE ASPHYXIANT.
CHRONIC: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.