ADVANCED SAFETY SYSTEMS INC -- SAFE STEP BASE
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BYMZW
MSDS NAME: SAFE STEP BASE
Kit Part: Y
Responsible Party
Name: ADVANCED SAFETY SYSTEMS INC
Address: 6834 S W 81 STREET
City: MIAMI FL 33143-7708
Info Phone: 305-666-9296
Emergency Phone Number: 305-666-9296
Proprietary Ind: Y
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: ADVANCED SAFETY SYSTEMS INC
Address: 6834 S W 81 STREET
City: MIAMI FL 33143-7708
=======================================================
Contractor Summary
=======================================================
Name: ADVANCED SAFETY SYSTEMS INC
Address: 6834 S W 81 STREET
City: MIAMI FL 33143-7708
Phone: 305-666-9296/800-633-9296
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: ORAL LD50(RATS): >10,000 MG/KG
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: SKIN: MODERATE IRRITANT. EYES: SLIGHT IRRITATION.
OVEREXPOSURE MAY CAUSE IRRITATION, SENSITIZATION & DERMATITIS.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: IRRITATION
First Aid: SKIN: PROMPTLY WASH W/MILD SOAP & WATER. EYES: IMMEDIATELY FLUSH
W/WATER FOR 15 MINS. INHALATION: REMOVE TO FRESH AIR, GIVE OXYGEN IF
DIFFICULTY BREATHING. INGESTION: DRINK WATER & INDUCE VOMITING. OB TAIN
MEDICAL ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CONTAIN W/ABSORBENT MATERIAL. IF NECESSARY, SOAK
CONTAMINATED AREA W/5% ACETIC ACID & WASH W/WATER. COLLECT IN A METAL
WASTE CONTAINER.
Waste Disposal Methods: DISPOSE OF IN A APPROVED LANDFILL/INCINERATE IN
ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS.
Handling And Storage Precautions: STORE CLOSED IN COOL, DRY AREA. WHEN
HANDLING/POURING, WEAR PROTECTIVE CLOTHING & RESPIRATORY PROTECTION.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: CC
Flash Point Text: 490F
Extinguishing Media: WATER, FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures: USE SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard: DECOMPOSITION & COMBUSTION PRODUCTS MAY BE
TOXIC.
=======================================================
Control Measures
=======================================================
Respiratory Protection: ORGANIC CHEMICAL CARTRIDGE RESPIRATOR IF NEEDED.
Ventilation: GOOD GENERAL MECHANICAL VENTILATION & LOCAL EXHAUST
Protective Gloves: IMPERVIOUS
Eye Protection: SPLASH-PROOF CHEMICAL GOGGLES
Other Protective Equipment: BARRIER CREAM RECOMMENDED
Work Hygienic Practices: MAINTAIN A SCHEDULE OF REGULAR HOUSEKEEPING TO INSURE
CLEANLINESS IN THE WORK AREA.
Supplemental Safety and Health: PH: (10% IN WATER).
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 392F
Vapor Pres: 1
Spec Gravity: 1.17
PH: (SUPP)
Solubility in Water: INSOLUBLE
Appearance and Odor: CLEAR LIQUID W/SLIGHT ODOR
Percent Volatiles by Volume: 0
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Materials To Avoid: STRONG OXIDIZING AGENTS
Hazardous Decomposition Products: CO, CO2, ALDEHYDES
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: STRONG ACIDS/BASES IN BULK
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: SAFE STEP BASE
Company: ADVANCED SAFETY SYSTEMS INC
Street: 6834 S W 81 STREET
City: MIAMI FL
Zipcode: 33143-7708
Health Emergency Phone: 305-666-9296
Label Required IND: Y
Date Of Label Review: 12/16/1998
Status Code: C
Label Date: 12/16/1998
Origination Code: G
Hazard And Precautions: SKIN: MODERATE IRRITANT. EYES: SLIGHT IRRITATION.
OVEREXPOSURE MAY CAUSE IRRITATION, SENSITIZATION & DERMATITIS.
IRRITATI
ON
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|