POLY SCIENTIFIC R & D CORP -- GOLD CHLORIDE 0.1% AQUEOUS, S201
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CGDGY
MSDS NAME: GOLD CHLORIDE 0.1% AQUEOUS, S201
Responsible Party
Name: POLY SCIENTIFIC R & D CORP
Address: 70 CLEVELAND AVE
City: BAY SHORE NY 11706
Info Phone: 516-586-0400
Emergency Phone Number: 800-424-9300 (CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: POLY SCIENTIFIC R&D CORP.
Address: 70 CLEVELAND AVE
City: BAY SHORE NY 11706
Phone: 516-586-0400
=======================================================
Ingredients
=======================================================
Cas: 16961-25-4
RTECS #: MD5428000
Name: GOLD CHLORIDE, HYDROCHLORIDE, TRIHYDRATE; (GOLD CHLORIDE)
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE/CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHALATION: REMOVE TO FRESH AIR, GIVE OXYGEN IF AVAILABLE. EYES:
FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH
COPIOUS AMOUNTS OF SOAP AND WATER. INGESTION: GIVE 2-4 GLA SSES OF WATER TO
CONSCIOUS VICTIM, INDUCE VOMITING, GET MEDICAL ATTENTION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: PICK UP SPILL WITH ABSORBENT VERMICULITE AND
CONTAINERIZE FOR PROPER DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: WASTE DISPOSAL METHODS COMPLIANCE WITH LOCAL, STATE,
AND FEDERAL REGULATIONS.
Handling And Storage Precautions: STORE IN A COOL, DRY, WELL-VENTILATED AREA.
PROTECT FROM PHYSICAL DAMAGE.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: DRY CHEMICAL, WATER SPRAY, ALCOHOLIC FOAM, CARBON DIOXIDE.
Fire Fighting Procedures: WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NEGLIGIBLE FIRE AND EXPLOSION HAZARD WHEN
EXPOSED TO HEAT OR FLAME.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH APPROVED SELF CONTAINED BREATHING APPARATUS.
Ventilation: LOCAL EXHAUST.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: EMERGENCY EYEWASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA (FP N). PROTECTIVE APRON.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 212F,100C
Vapor Pres: 14
Vapor Density: 0.7
Spec Gravity: 1.0
Evaporation Rate & Reference: >1
Solubility in Water: YES
Appearance and Odor: YELLOW CLEAR COLORLESS LIQUID
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: HEATING TO 180C WHERE EVOLUTION OF HAZARDOUS
FUMES MAY OCCUR.
Materials To Avoid: AVOID OVERHEATING.
Hazardous Decomposition Products: HAZARDOUS FUMES.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: GOLD CHLORIDE 0.1% AQUEOUS, S201
Company: POLY SCIENTIFIC R&D CORP.
Street: 70 CLEVELAND AVE
City: BAY SHORE NY
Zipcode: 11706
Health Emergency Phone: 800-424-9300 (CHEMTREC)
Label Required IND: Y
Date Of Label Review: 01/29/1998
Status Code: C
Label Date: 01/29/1998
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: None
Contact Hazard: None
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE/CHRONIC: NONE SPECIFIED BY
MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.