Search   
MSDS  : ANL-RC/HT, FG06182
CAS  : 25852-47-5
9011-14-7
7732-18-5
81-07-2
635-46-1
80-15-9
NAME  : polyethylene glycol dimethacrylate (mfr's cas #41637-38-1)
polymethylmethacrylate; (poly (methyl methacrylate))
water; (hydrogen oxide)
o-benzoic sulfimide (sara 313) (cercla)
1,2,3,4-tetrahydroquinone
cumene hydroperoxide (sara 313) (cercla)
PACER TECHNOLOGY -- ANL-RC/HT, FG06182
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CHGRK
MSDS NAME: ANL-RC/HT, FG06182
Responsible Party
Name: PACER TECHNOLOGY
Address: 9420 SANTA ANITA AVE
City: RANCHO CUCAMONGA CA 91730
Info Phone: 909-987-0550
Emergency Phone Number: 800-424-9300(CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: PACER TECHNOLOGY
Address: 9420 SANTA ANITA AVENUE
City: RANCHO CUCAMONGA CA 91730
Phone: 909-987-0550
=======================================================
Ingredients
=======================================================
Cas: 25852-47-5
Name: POLYETHYLENE GLYCOL DIMETHACRYLATE (MFR'S CAS #41637-38-1)
% Wt: 60-100
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 9011-14-7
RTECS #: TR0400000
Name: POLYMETHYLMETHACRYLATE; (POLY (METHYL METHACRYLATE))
% Wt: 5-10
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 7732-18-5
RTECS #: ZC0110000
Name: WATER; (HYDROGEN OXIDE)
% Wt: 1-5
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 81-07-2
RTECS #: DE4200000
Name: O-BENZOIC SULFIMIDE (SARA 313) (CERCLA)
% Wt: 0-1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
EPA Rpt Qty: 100 LBS
DOT Rpt Qty: 100 LBS
------------------------------
Cas: 635-46-1
RTECS #: 9999999ZZ
Name: 1,2,3,4-TETRAHYDROQUINONE
% Wt: 0-1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 80-15-9
RTECS #: MX2450000
Name: CUMENE HYDROPEROXIDE (SARA 313) (CERCLA)
% Wt: 0-1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
EPA Rpt Qty: 10 LBS
DOT Rpt Qty: 10 LBS
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: YES
OSHA: NO
Effects of Exposure: ACUTE:SKIN AND EYE IRRITATION. SIGNS AND SYMPTOMS OF
EXPOSURE:SKIN CONTACT:IRRITATION UPON DIRECT CONTACT. CHRONIC:PROLONGED OR
REPEATED SKIN CONTACT MAY CAUSE DERMATITIS IN SENSITIVE INDIVIDUALS.
Explanation Of Carcinogenicity: O-BENZOIC SULFIMIDE:IARC MONOGRAPHS,
SUPPLEMENT, VOL 7, PG 334, 1987:GROUP 2B.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: PRE-EXISTING SKIN & RESPIRATORY
CONDITIONS.
First Aid: EYES:IMMEDIATELY FLUSH W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. SKIN:REMOVE CONTAMINATED CLOTHING & WASH AFFECTED AREAS W/SOAP
& WATER. INHAL:REMOVE TO FRESH AIR. PERFORM ARTIFICIAL RESPIRA TION IF
BREATHING HAS STOPPED. INGEST:DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SOAK UP W/INERT ABSORBENT. PLACE INTO CONTAINER FOR
DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE TO LOCAL, STATE & FEDERAL
EPA REGULATIONS.
Handling And Storage Precautions: STORE BELOW 100F OUT OF DIRECT SUNLIGHT.
Other Precautions: AVOID SKIN AND EYE CONTACT.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TOC
Flash Point Text: 302F,150C
Extinguishing Media: WATER SPRAY, FOAM OR CARBON DIOXIDE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). COOL CONTAINERS W/WATER SPRAY.
Unusual Fire/Explosion Hazard: COMBUSTION WILL PRODUCE CARBON DIOXIDE &
CARBON MONOXIDE GASES.
=======================================================
Control Measures
=======================================================
Respiratory Protection: A NIOSH APPROVED VAPOR CANISTER MAY BE USED IF VAPOR
BECOMES IRRITATING.
Ventilation: LOCAL EXHAUST:GOOD. MECHANICAL (GENERAL):AS NEEDED.
Protective Gloves: COTTON GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N). PROTECTIVE CLOTHING.
Work Hygienic Practices: WASH HANDS W/SOAP & WATER AFTER USE. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health: SOL IN H*2O:SOLUBLE, W/REMAINDER INSOLUBLE.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >204F,>96C
Spec Gravity: 1.12 (H*2O=1)
Solubility in Water: 3.8% BY WT (SUPDAT)
Appearance and Odor: TRANSPARENT GREEN LIQUID W/MILD ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: HIGH TEMPERATURES & DIRECT SUNLIGHT.
Materials To Avoid: REDUCING AGENTS (IRON, COPPER POWDER).
Hazardous Decomposition Products: THERMAL DECOMPOSITION COULD PRODUCE CARBON
MONOXIDE, CARBON DIOXIDE & UNIDENTIFIED ORGANIC COMPOUNDS.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: ANL-RC/HT, FG06182
Company: PACER TECHNOLOGY
Street: 9420 SANTA ANITA AVENUE
City: RANCHO CUCAMONGA CA
Zipcode: 91730
Health Emergency Phone: 800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 06/25/1998
Status Code: C
Label Date: 06/25/1998
Origination
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Moderate
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE:SKIN AND EYE IRRITATION. SIGNS AND SYMPTOMS OF
EXPOSURE:SKIN CONTACT:IRRITATION UPON DIRECT CONTACT. CHRONIC:CANCER HAZARD.
CONTAINS SACCHARIN (O-BENZOIC SULFIMIDE), WHICH IS LISTED AS A CARCINO GEN
(FP N). PROLONGED OR REPEATED SKIN CONTACT MAY CAUSE DERMATITIS IN SENSITIVE
INDIVIDUALS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
SAFE TAP PLUS, 71915
SAFE TAP PLUS, 71914
SAFE TAP PLUS, 71913
SAFE TAP PLUS, 71911
PERMATEX PRUSSIAN BLUE NON-DRYING, 80038, 35V 8009-03-8
14038-43-8
64742-52-5
64742-53-6
DEPEND 7387 ACTIVATOR, 18861 142-82-5
68411-20-1
67-63-0
13395-16-9
06 264T24R SOVAPON CURING AGT
METEX 9295 SOLDER REMOVER, 19295
JOINT COMPOUND, RED DOT (ALL PURPOSE) 93763-70-3
12174-11-7
14808-60-7
34375-28-5
111-46-6
12001-26-2
1317-65-3
38-1000 68410-95-7
3738 GRAY PRIMER, THE FRESH LOOK FAST (SUPDAT) 74-98-6
106-97-8
108-88-3
1330-20-7
67-63-0
67-64-1
110-19-0
14807-96-6
13463-67-7
3740 ALMOND, THE FRESH LOOK FAST DRYING (SUPDAT) 74-98-6
106-97-8
100-41-4
1330-20-7
67-64-1
13463-67-7
3743 GOLD, THE FRESH LOOK FAST DRYING (SUPDAT) 74-98-6
106-97-8
108-88-3
100-41-4
1330-20-7
1100, THE PERFORMER CONTROLS RUST SPRAY (SUPDAT) 74-98-6
106-97-8
108-88-3
67-63-0
67-64-1
110-19-0
14807-96-6
13463-67-7
FRP-94-057 POLYESTER RESIN
PROTECH SKIN BARRIER CREAM, FG10005 12428-46-5
8005-44-5
8042-47-5
59-50-7
81-88-9
MIRROLAC FLAT BLACK, DV7103
INSULATING VARNISH, 74010 71-36-3
108-88-3
68610-56-0
107-98-2
108-10-1
1330-20-7
111-40-0
100-41-4
71-43-2
CONFIDENCE 10C 100-37-8
1310-73-2
1310-58-3
ANL-RC/HT, FG06180 25852-47-5
9011-14-7
7732-18-5
81-07-2
635-46-1
80-15-9
ANL-RC/HT, FG06182 25852-47-5
9011-14-7
7732-18-5
81-07-2
635-46-1
80-15-9
ANL-RC/HT, FG06181 25852-47-5
9011-14-7
7732-18-5
81-07-2
635-46-1
80-15-9
ANL-RC/HT, FG06183 25852-47-5
9011-14-7
7732-18-5
81-07-2
635-46-1
80-15-9
22972, DPD COMPOUND FOR FREE AND TOTAL (SUPDAT)
23140, FREE CHLORINE INDICATOR SOLUTION FOR (SUP DAT) 6192-52-5
7732-18-5
RONASTAN EC PART A, 45070 67-56-1
120-80-9
STANNOUS SULFATE, 20483 7488-55-3
STARGOLD C-25 SHIELDING GAS MIXTURE 124-38-9
7440-37-1
GRIP CEMENT POWDER 7790-75-2
9011-14-7
9005-09-8
94-36-0
GRIP CEMENT LIQUID 80-62-6
99-97-8
123-31-9
ALUMINUM PASTE (LEAFING), 100 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 104 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 124 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 125 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 130 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 133 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 134 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 138 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 154 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 160 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 164 7429-90-5
64742-88-7
57-11-4
ALUMINUM PASTE (LEAFING), 180 7429-90-5
64742-88-7
57-11-4
2 INDUSTRIAL-STRENGTH LUBRICANT, 00216 64742-47-8
64742-53-6
124-38-9
HP C3967A-PRINT DRUM, C3967A
P/N 74-6615/88-5141/74-6610/L2H/L2G/L3H/L3B/L52S PROTOSLO
MR225 87-X26 64742-89-8
67-63-0
1330-20-7
8052-41-3
FLEET WELD 35 COVERED ELECTRODE, SIZE-ALL 65996-61-4
7439-89-6
1344-09-8
13463-67-7
1309-48-4
7439-96-5
584-08-7
1332-58-7
7439-89-6
CP-28,76000 1317-33-5
80054 PERMATEX HYDRAULIC JACK OIL, PN:78E 64742-52-5
NITROGEN 7727-37-9

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net