HUMCO LABORATORY INC -- STRONG IODINE SOLUTION USP
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BSNHL
MSDS NAME: STRONG IODINE SOLUTION USP
Responsible Party
Name: HUMCO LABORATORY INC
Address: 1008 WHITAKER ST
City: TEXARKANA TX 75501
Info Phone: 903-793-3174
Emergency Phone Number: 800-424-9300
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: HUMCO LABORATORY, INC
Address: 7400 ALUMAX DRIVE
City: TEXARKANA TX 75501
=======================================================
Contractor Summary
=======================================================
Name: HUMCO LABORATORY, INC
Address: 7400 ALUMAX DRIVE
City: TEXARKANA TX 75501
Phone: 903-831-7808/800-662-3435
=======================================================
Ingredients
=======================================================
Cas: 7553-56-2
RTECS #: NN1575000
Name: IODINE
% Wt: 5
Other REC Limits: 0.1 PPM
OSHA PEL: 1 MG/CUM
ACGIH TLV: C 1.0 MG/CUM
------------------------------
Cas: 7681-11-0
RTECS #: TT2975000
Name: POTASSIUM IODIDE, POTIDE, HYDRIOCIC ACID, POTASSIUM SALT
% Wt: 10
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: INHALATION: VAPORS MAY CAUSE IRRITATION TO EYES, SKIN,
& MUCOUS MEMBRANES. EYES: SEVERE IRRITATION, BURNS. SKIN: SEVERE
IRRITATION & BURNS. INGESTION: MAY CAUSE UNCONSCIOUSNESS.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: INHALATION: HEADACHES, TIGHT CHEST.
INGESTION: NAUSEA, VOMITING, & LOSS OF CONSCIOUSNESS. EYES: LACRIMATION.
First Aid: INGESTION: DON'T INDUCE VOMITING. IF CONSCIOUS, GIVE WATER, MILK, OR
MILK OF MAGNESIA. SKIN/EYES: IMMEDIATELY FLUSH W/PLENTY OF WATER FOR 15 MINS.
OBTAIN MEDICAL ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: WEAR SCBA & FULL PROTECTIVE CLOTHING. USE WATER
SPRAY TO REDUCE VAPORS. TAKE UP W/SAND OR OTHER NON-COMBUSTIBLE ABSORBENT
MATERIAL. FLUSH AREA W/WATER.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, & FEDERAL
REGULATIONS.
Handling And Storage Precautions: STORE IN TIGHTLY CLOSED CONTAINER. PROTECT
CONTAINER FROM PHYSICAL DAMAGE. AVOID BREATHING VAPORS. PREVENT PROLONGED EYE
& SKIN CONTACT.
Other Precautions: CERTAIN INDIVIDUALS MAY DEVELOP SENSITIZATION TO IODINE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: NON-FLAMMABLE
Extinguishing Media: USE EXTINGUISHING MEDIA APPROPRIATE FOR THE SURROUNDING
FIRE.
Unusual Fire/Explosion Hazard: IODINE IS AN OXIDIZING AGENT THAT WILL SUPPORT
COMBUSTION/REACT W/EXPLOSIVE VIOLENCE WHEN HEATED IN COMBINATION W/SOME
INCOMPATIBLE MATERIALS.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE APPROVED SELF-CONTAINED RESPIRATOR.
Ventilation: LOCAL & MECHANICAL (GENERAL) EXHAUST: TO MEET 0.1 PPM CEILING
LIMIT.
Protective Gloves: RUBBER
Eye Protection: SAFETY GOGGLES OR FULL FACEPIECE
Work Hygienic Practices: GOOD PERSONAL HYGIENE & WASH HANDS BEFORE EATING,
DRINKING OR SMOKING.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 100C
Solubility in Water: COMPLETE
Appearance and Odor: DARK BROWN SOLUTION W/CHARACTERISTIC IODINE ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Materials To Avoid: ACETALDEHYDE, ACETYLENE, AMMONIA, POWDER METALS, ALKALI
METALS, STRONG REDUCING AGENTS, AMMONIUM HYDROXIDE
Hazardous Decomposition Products: AMMONIUM HYDROXIDE REACTS TO FORM IODIDES,
WHICH ARE SHOCK SENSITIVE & EXPLOSIVE WHEN DRY.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: STRONG IODINE SOLUTION USP
Company: HUMCO LABORATORY, INC
Street: 7400 ALUMAX DRIVE
City: TEXARKANA TX
Zipcode: 75501
Health Emergency Phone: 800-424-9300
Label Required IND: Y
Date Of Label Review: 11/22/1993
Status Code: C
Label Date: 11/22/1993
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Severe
Contact Hazard: Severe
Fire Hazard: None
Reactivity Hazard: Slight
Hazard And Precautions: INHALATION: VAPORS MAY CAUSE IRRITATION TO EYES, SKIN,
& MUCOUS MEMBRANES. EYES: SEVERE IRRITATION, BURNS. SKIN: SEVERE
IRRITATION & BURNS. INGESTION: MAY CAUSE UNCONSCIOUSNESS. TARGET ORGANS:
SKIN, E YES, & RESPIRATORY SYSTEM. CARCINOGEN: NICKEL
& CHROMIUM.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|
ALL PAGES On Chemical Property IN THIS GROUP
| NAME | CAS |
81041 RONASCREEN OPSR 5600 CODE D
| 112-07-2 34590-94-8 111-77-3 112-15-2 64742-94-5 |
01-D0314-000 RESOLVE CARPET CLEANER W/TEFLON
| 67-63-0 107-98-2 |
HI 7010,PH 10.01 BUFFER SOLUTION
| 121-54-0 7732-18-5 144-55-8 497-19-8 |
HI 7007,PH 7.01 BUFFER SOLUTION
| 7778-77-0 7558-79-4 121-54-0 7732-18-5 |
CANON TONER FOR CLC 200/300 (YELLOW)
| |
9391071-3, PC94-3 HI-SHEAR INITIATOR
| 7440-67-7 7778-74-7 11140-68-4 |
AWS A5.1 LV6011,LV6013,LV7018 MILD STEEL ELECTRODES
| 1317-65-3 7439-89-6 7439-96-5 1312-76-1 13463-67-7 7789-75-5 |
COLORTREND, 888-0018 KX-TITANIUM WHITE
| 107-21-1 111-46-6 13463-67-7 14807-96-6 7631-86-9 |
COLORTREND, 888-2009 L-RAW UMBER
| 107-21-1 111-46-6 14807-96-6 |
4449 CHLORINE REAGENT #2
| 50-21-5 7732-18-5 |
0495648 HAEMO-SOL HIGH SUDS
| 497-19-8 7758-29-4 144-55-8 57-13-6 25155-30-0 7757-82-6 9004-32-4 |
HIGH SUDS (NON PHOS)
| 7757-82-6 57-13-6 144-55-8 25155-30-0 64-02-8 497-19-8 9004-32-4 |
5957 SUPER DUTY PASTE COMPOUND
| 7732-18-5 1317-95-9 8008-20-6 8052-41-3 112-80-1 110-91-8 8002-09-3 |
HIL-TEX
| 111-90-0 78-51-3 1314-13-2 7732-18-5 25608-33-7 25585-75-5 |
0531A NUTRA-RINSE
| 7732-18-5 64-02-8 9016-45-9 64972-19-6 |
4500 CHLORINE REAGENT #3
| 1310-73-2 88-14-2 10102-17-7 7732-18-5 |
6321
| |
LME LIME STRIPPER
| |
5043 AEROSOL CUTTING OIL
| 68476-86-8 71-55-6 |
9392151-2 (PC94-4) HI-SHEAR INITIATOR
| 7440-67-7 7778-74-7 |
EA DETERGENT
| 7758-29-4 57-13-6 144-55-8 25155-30-0 68439-46-3 9016-45-9 9014-01-1 497-19-8 9004-32-4 |
HEEF 25-C
| |
STRONG IODINE SOLUTION USP
| 7553-56-2 7681-11-0 |
0599C TOP CLEAN
| 7732-18-5 68439-46-3 64972-19-6 64-02-8 1330-72-7 |
THA007 INTERLINE EPOXY SPRAYABLE CAULK BASE
| |
KPR DEVELOPER
| 1330-20-7 110-49-6 100-41-4 |
5954, 5955, 5956 3M BRAND SUPER DUTY RUBBING COMPOUND
| 8052-41-3 64741-88-4 112-80-1 1317-95-9 7732-18-5 8008-20-6 |
HBC-3B-1 (PRECOAT)
| 7732-18-5 7784-30-7 64-17-5 1344-28-1 7697-37-2 |
160321-B PRO-PLUG 321 BALL PLUGGING COMPOUND, BLACK
| |
APA50-1
| |
TH5-2
| |
GLAS-GRIP 637 SE
| 142-82-5 9003-55-8 65997-05-9 |
JOINT COMPOUND GREEN DOT TOPPING
| 1317-65-3 14808-60-7 |
22162 FLUORIDE REAGENT AMPULES DUAL RANGE
| 7647-01-0 7784-46-5 7732-18-5 |
NEUTONE
| 64742-88-7 64742-43-4 8006-44-8 |
PRINT CARTRIDGES FOR DESKJET 500C & DESKWRITER C
| 111-29-5 75-57-0 7732-18-5 |
DAP BLEND STICK
| |
ULTRA ALL FREE CLEAN POWDER LAUNDRY DETERGENT
| 497-19-8 1344-09-8 93763-70-3 |
103613 LIQUID POR-SAN
| 7732-18-5 14808-60-7 144-62-7 |
AEC-1, ENGINE CLEAN, ENVIRONMENTALLY RESPONSIBLE
| |
F41-7701-000 TONER BLACKE NPG-2
| |
BRAZE 403, BRAZE 404, BRAZE 505, BRAZE 541
| 7440-50-8 7440-02-0 7440-22-4 7440-66-6 |
METHYL ETHYL KETONE
| 78-93-3 |
SILICONE OIL
| |
GREENSTUFF N-95
| 111-76-2 1310-58-3 |
ULTRA "ALL" FREE CLEAR POWDER LAUNDRY DETERGENT
| |
DURO ALL PURPOSE SPRAY ADHESIVE
| 110-54-3 115-10-6 |
COREXIT 9554
| |
BLAIR WORKABLE MATTE FIX
| 141-78-6 67-64-1 78-93-3 123-86-4 67-63-0 74-98-6 111-76-2 71-36-3 75-28-5 106-97-8 |
3M IMPERIAL MICROFINISHING COMPOUND-LIQUID
| 7732-18-5 1317-95-9 64742-47-8 64741-88-4 56-81-5 78-83-1 |
|
|