HERNON MFG INC -- REACT 730
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BSQXM
MSDS NAME: REACT 730
Responsible Party
Name: HERNON MFG INC
Address: 121 TECH DR
City: SANFORD FL 32771
Info Phone: 407-322-4000
Emergency Phone Number: 407-322-4000
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: HERNON MANUFACTURING
Address: 121 TECH DRIVE
City: SANFORD FL 32771
Phone: 407-322-4000/800-255-3924
=======================================================
Ingredients
=======================================================
Cas: 79-41-4
RTECS #: OZ2975000
Name: METHACRYLIC ACID
Other REC Limits: 70 MG/M3, S (MFR)
OSHA PEL: 20 PPM, S
ACGIH TLV: 20 PPM
------------------------------
Name: ALKYL METHACRYLATE
Other REC Limits: 250 PPM
-----------------------------
Cas: 80-15-9
RTECS #: MX2450000
Name: HYDROPEROXIDE; ALPHA, ALPHA-DIMETHYLBENZYL-; (CUMENE HYDROPEROXIDE)
EPA Rpt Qty: 10 LBS
DOT Rpt Qty: 10 LBS
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: IRRITATION OF EYES, NOSE & THROAT.
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: SKIN DISEASES, ASTHMA.
First Aid: INHAL: REMOVE TO FRESH AIR. IF SYMPTOMS PERSIST SEEK MEDICAL
ATTENTION. SKIN: FLUSH W/WATER. EYES: FLUSH W/WATER FOR AT LEAST 15 MINUTES.
SEEK MEDICAL ATTENTION. INGEST: DO NOT INDUCE VOMITING. SEEK M EDICAL
ATTENTION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SOAK UP IN INERT ABSORBENT MATERIAL. STORE IN CLOSED
CONTAINER UNTIL DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: INCINERATE FOLLOWING FEDERAL, STATE, & LOCAL
REGULATIONS.
Handling And Storage Precautions: STORE BELOW 90 F TO PRESERVE SHELF LIFE.
AVOID PROLONGED SKIN CONTACT.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: CC
Flash Point Text: 188F,87C
Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FR N).
Ventilation: PROVIDE SUFFICIENT LOCAL VENTILATION TO MAINTAIN VAPOR BELOW TLV.
Protective Gloves: RUBBER OR PLASTIC RECOMMENDED.
Eye Protection: ANSI APRV CHEMICAL WORKERS GOGGLES (FP N
Other Protective Equipment: NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices: WASH HANDS AFTER USE. FOLLOW STANDARD HYGENIC
PRACTICES.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >300F,>149C
Vapor Pres: <10 @ 80F
Spec Gravity: 1.1 (H*2O=1)
Solubility in Water: LOW
Appearance and Odor: AMBER LIQUID, SHARP ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: NONE.
Hazardous Decomposition Products: NONE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: REACT 730
Company: HERNON MANUFACTURING
Street: 121 TECH DRIVE
City: SANFORD FL
Zipcode: 32771
Health Emergency Phone: 407-322-4000
Label Required IND: Y
Date Of Label Review: 04/15/1993
Status Code: C
Label Date: 04/15/1993
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. IRRITATION OF EYES, NOSE AND THROAT.
CHRONIC: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.