WACKER MEXICANA -- RTV SILICONE DISPERSION J-501
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWQMX
MSDS NAME: RTV SILICONE DISPERSION J-501
Responsible Party
Name: WACKER MEXICANA
Address: AV PERIFERICO SUR 3343 PH
City: MEXICO, DF NK 10200
Country: MX
Info Phone: 525-229-5500
Emergency Phone Number: 525-229-5500
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: WACKER MEXICANA
Address: AV PERIFERICO SUR 3343 PH
City: MEXICO, DF NK 10200
Country: MX
Phone: 525-229-5500
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYE:IRRIT. SKIN:IRRIT, MAY CAUSE DEFAT. INHAL:RESP TRACT
IRRIT. INGEST:NO TOX EFTS EXPECTED. ACUTE/CHRONIC:NOT KNOWN. HUMAN HLTH HAZS
APPLY ONLY TO PROD AS PACKAGED & IN ITS COMPLETELY CURED FORM. HAZ S OF
CURE BY-PRODS ARE DESCRIBED AS FOLLOWS. MATL RELSES CYCLOHEXYLAMINE UPON
MOISTURE CURING. EXPOS (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZS:TO CYCLOHEXYLAMINE VAPS MAY
CAUSE IRRIT OF EYES, MUCOUS MEMBRANES & SKIN. DIRECT CONT W/EYES &
SKIN WILL CAUSE BURNS & MAY CAUSE PERM DMG. REVERSIBLE NARCOTIC EFT WAS
NOTED IN THREE CASES OF ACUTE HUMAN EXPOS. POSITIVE MUTAGENIC RSLTS WERE
NOTED IN TWO EXPERS. UPON COMPLETION OF CURING PROCESS, (SUP DAT)
Medical Cond Aggravated By Exposure: THERE ARE NOT DATA AVAILABLE WHICH ADDRESS
MEDICAL CONDITIONS WHICH ARE GENERALLY RECOGNIZED AS BEING AGGRAVATED BY
EXPOSURE TO THIS PRODUCT.
First Aid: EYE:FLUSH WELL W/LG AMTS OF RUNNING WATER FOR AT LST 15 MIN. HOLD
EYELIDS APART TO INSURE RINSING OF ENTIRE SURF OF EYE & LIDS W/WATER. GET
MED ATTN IMMED. SKIN:REMOVE EXCESS MATL W/WATERLESS SKIN CLE ANER. FLUSH WELL
W/WATER & WASH WELL W/WATER & SOAP. REMOVE CONTAM CLTHG & SHOES.
GET MED ATTN IMMED. INGEST:GIVE SEVERAL GLASSES OF WATER & INDUCE VOMIT
BY PLACING FINGER ON BACK OF VICTIM'S
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: MAKE SURE ALL PERS INVOLVED IN SPILL CLEANUP FOLLOW
GOOD INDUST HYGIENE PRACT (REFER TO HYGIENE PRACT). ANY PERSON ENTERING
SIGNIFICANT SPILL AREA OR AN UNKNOWN CONCENTRATION OF VAPOR OR AEROSOL SHOUL
D USE A NIOSH/MSHA POSITIVE-PRESSURE SCBA
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF EMPTY CONTAINERS ACCORDING TO ANY APPLICABLE
REGUFEDERAL, STATE AND LOCAL REGULATIONS UNDER THE RESOURCE CONSERVATION AND
RECOVERY ACT. NOTE:STATE AND LOCAL REGULATIONS MAY BE MORE STRINGEN T THAN
FEDERAL.
Handling And Storage Precautions: STORE IN A COOL, DRY, WELL VENTILATED AREA.
EXERCISE DUE CAUTION TO PREVENT DAMAGE TO THE CONTAINER. THIS PROD IS
CONSIDERED FLAM LIQ & IS FIRE HAZ.
Other Precautions: IT SUPPORTS COMBUST & DECOMPOSES UNDER FIRE CNDTNS TO
GIVE OFF TOX MATLS. DO NOT USE WELDING/CUTTING TORCH ON/NEAR ANY CNTNR OF
MATL, EVEN IF EMPTY, BECAUSE AN EXPLO CAN OCCUR. DO NOT POUR, SPILL/STOR E
NEAR HEAT, SPK SOURCES/OPEN
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: PMCC
Flash Point Text: 57.0F,13.9C
Extinguishing Media: USE STANDARD FIRE FIGHTING TENIQUES TO EXTINGUISH FIRES
INVOLVING THIS MATL:USE WATER SPRAY, DRY CHEM OR CARBON DIOXIDE.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). AS IN ANY FIRE, PVNT HUMAN EXPOS TO FIRE, SMK, FUMES/PRODS OF COMBUST.
EVAC NON-ESSNTL PERS FROM (SUP DAT)
Unusual Fire/Explosion Hazard: VAPS ARE HVR/AIR & MAY TRAVEL ALONG GROUND,
BE MOVED BY VENT SYS, SETTLE IN PITS/LOW AREAS, & BE IGNITED BY IGNIT
SOURCES DIST FROM HNDLG PT. TO PVNT (SUP DAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: IF USE CNDTNS GENERATE AIRBORNE CONTAM, MATL SHOULD BE
HNDLD IN AN OPEN (E.G., OUTDOOR)/WELL VENT AREA. WHERE ADEQ VENT IS NOT
AVAIL, USE NIOSH/MSHA APPRVD ORG VAP RESPS W/DUST, MIST & FUME FILTER TO
REDUCE EXPOS. WHERE EXPOS POTNTL
Ventilation: IN THOSE CASES WHERE ENGINEERING CONTROLS ARE INDICATED BY USE
CNDTNS, FOLLOWING TRADITIONAL EXPOS CONTROL
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYEWASH STATIONS & SFTY SHOWERS SHOULD BE EASILY
ACCESSIBLE. SKIN CONT SHOULD BE MINIMIZED THRU USE OF
Work Hygienic Practices: ALL FOOD SHOULD BE KEPT IN A SEPARATE AREA AWAY FROM
STOR/USE LOCATION. EATING, DRINKING & SMKNG SHOULD BE
Supplemental Safety and Health: NOTE:USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). FIRE FIGHT PROC:FIRE AREA. EXPLO
HAZS:FIRE/EXPLO FROM STATIC ACCUM & DISCHARGE, EFTIVELY GROUND MATL
TRANSFER SYS. CNDTNS T O AVOID:CLSD TO PVNT EXPOS TO MOISTURE.EFTS OF
OVEREXP:CYCLOHEXYLAMINE WILL NO LONGER BE RELSD.
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Pres: <1
Vapor Density: 3.4
Spec Gravity: 0.96 (H*2O=1)
Solubility in Water: NEGLIGIBLE
Appearance and Odor: VARIOUS COLORED LIQUIDS AMMONIACAL ADOR.
Percent Volatiles by Volume: 35
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: REACTS W/ATM MOISTURE TO FORM CURED SEALANT,
RELSNG CYCLOHEXYLAMINE UNTIL CURING PROCESS IS COMPLETE. KEEP CNTNR(SUPDAT)
Materials To Avoid: UNCURED MATL:AVOID CONT W/WATER, ACIDS, ALCOHOL, STRONG
ALKALIES, STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products: SIO*2, CO, CO*2 AND VARIOUS HYDROCARBON
FRAGMENTS.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: RTV SILICONE DISPERSION J-501
Company: WACKER MEXICANA
Street: AV PERIFERICO SUR 3343 PH
City: MEXICO, DF NK
Zipcode: 10200
Country: MX
Health Emergency Phone: 525-229-5500
Label Required IND: Y
Date Of Label Review: 02/21/1995
Status Code: C
Label Date: 02/21/1995
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Moderate
Fire Hazard: Severe
Reactivity Hazard: Slight
Hazard And Precautions: EXTREMELY FLAMMABLE. AVOID WATER. ACUTE:EYE:IRRITATION.
SKIN:IRRITATION, MAY CAUSE DEFATTING. INHAL:RESPIRATORY TRACT IRRITATION.
CHRONIC:NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|
ALL PAGES On Chemical Property IN THIS GROUP
| NAME | CAS |
EMG 308
| |
RESTORE PLUS-ACID RADIATOR CLEANER
| |
HEEF 25-C
| |
HEEF 25-R
| |
RTV SILICONE DISPERSION J-501
| |
EBECRYL 3702, 022 L018
| |
ELERCYL 657, 022L092
| |
EBECRYL 3200, 022L006
| |
EBECRYL 3201, 022L021
| |
EBECRYL 3608, 022L112
| |
EBERCRYL 81, 022L170
| |
DISLON, 6500
| |
HE-175
| 64742-65-0 |
GREASED LIGHTNING BUILT ALKALINE CLEANER (SUPP DATA)
| |
PURPLE POWER CLEANER/DEGREASER
| 1310-73-2 111-76-2 |
ALL SEASON PRESOAK
| |
TECH-LUBE TLB
| |
CLEAR POOL
| 122-18-9 |
WEATHER BLOK BAIT
| |
ULTRATHANE CS-100 COMPONENT A (RESIN)
| |
ULTRATHANE CS-100 COMPONENT B (CURATIVE)
| |
DESMOPHEN 670A-80, D-518
| |
STARCH INDICATOR SOLUTION, 4170
| 54-21-7 9005-25-8 |
SODIUM ARSENITE SOLUTION, 4128
| 7784-46-5 1310-73-2 7732-18-5 |
IRON REDUCING REAGENT, 2777
| |
ISOCYANURATE REAGENT, 7455
| 7647-14-5 2893-78-9 |
GLYCINE SOLUTION, 6811
| 56-40-6 |
CYANURIC ACID TEST SOLUTION, 4856
| 64-19-7 7732-18-5 127-08-2 108-78-1 |
COPPER REAGENT, 6446
| 1336-21-6 108-88-3 7732-18-5 148-18-5 |
AMMONIA NITROGEN REAGENT 2, V-4798
| 1310-58-3 7487-94-7 7732-18-5 7681-11-0 |
BUFFER SOLUTION, PH 4.01, 2807
| 877-24-7 7732-18-5 |
BUFFER SOLUTION, PH 9.18, 2809
| 1303-96-4 7732-18-5 |
ALKALINITY TITRATION REAGENT B, 4493
| 7664-93-9 |
ACID PHENANTHROLINE INDICATOR, 2776
| 7664-93-9 66-71-7 7732-18-5 |
VUL-CUP 40K3 ORGANIC PEROXIDE
| 25155-25-3 66402-68-4 1067-53-4 96319-55-0 |
GEOGARD ONE COMPONENT BLACK
| |
TAME DRAIN OPENER, 66370
| 7664-93-9 64742-47-8 |
101 THINNER
| 9005-90-7 |
AEROGLAZE 9958 CL-C
| 100-41-4 108-65-6 70657-70-4 1330-20-7 78-93-3 108-88-3 123-86-4 |
UNI-REZ 2810
| |
OCTOBLEN
| |
DOLPHON, CC-1118-LV
| |
ASCEND, 102721
| 7173-51-5 8001-54-5 |
CELLOKYD 3378-T, 95-929
| |
AMERCOAT, 892HS
| |
LACQUER THINNER, 59-40
| |
HELIOGEN BLUE L 7101 F, 3532751
| |
SO SURE CORROSION PREVENTATIVE COMPOUND
| 64742-88-7 25619-56-1 25619-56-1 |
CORROSION PREVENTIVE PETROLATUM SPRAYING APPLICATION 972D800
| 64475-85-0 |
CORROSION PREVENTIVE PETROLATUM, SPRAYING APP 972D801
| 6447-58-5 |
|
|