Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:INHALATION: NUISANCE DUST MAY CAUSE
IRRITATION OF MUCOUS MEMBRANES/NOSE &
THROAT/DIZZINESS/PULMONARY/RESPIRATORY IRRITANT/CHEST
TIGHTNESS/METAL FUME FEVER/DRY THROAT/COUGHING/LOW BACK
PAIN/FATIGUE/HEA DACHE/MUSCLE ACHE. SKIN: ALLERGIC
REACTIONS/DERMATITIS.INGESTION: METALLIC TASTE/NAUSEA/BURNS &
VOMITING. EYES: INJURY.
Explanation of Carcinogenicity:CHROMIUM & NICKEL ARE ANIMAL & HUMAN
CARCINOGENS.
Effects of Overexposure:INHALATION: POSSIBLE LUNG FIBROSIS, RESPIRATORY
HYPERSENSITIVITY/AFFECTS CENTRAL NERVOUS SYSTEM/MUSCULAR WEAKNESS,
TREMORS, SYMPTOMS SIMILAR TO PARKINSON'S DISEASE & SIDEROSIS
(BENIGN). ELECTRIC SHOCK CAN KILL. SHIELDING GASES CAN
DISPLACEBREATHING AIR & CAUSE ASPHYXIATION IN CONFINED WORK
SPACES/UNVENTILATED AREAS.
Medical Cond Aggravated by Exposure:RESPIRATORY ALLERGIC CONDITIONS.
SOME STUDIES SHOW A HIGHER LEVEL OF LUNG RELATED PROBLEMS AMONG
OLDER WORKERS WHO SMOKE THAN THOSE WHO DID NOT SMOKE.
======================= First Aid Measures =======================
First Aid:SKIN/EYES: FLUSH W/WATER FOR AT LEAST 15 MINS. INHALATION:
REMOVE VICTIM FROM THE WELDING AREA. IF VICTIM IS UNCONSCIOUS,
ADMINISTER OXYGEN. IF VICTIM IS NOT BREATHING, BEGIN RESUSCITATION.
INGESTION: EMPLOY THE FIRST AID TECHNIQUES RECOMMENDED BY THE
AMERICAN RED CROSS. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Extinguishing Media:EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:READ & UNDERSTAND ANSI Z49.1 "SAFETY IN
WELDING & CUTTING" & NFPA STANDARD 51B FOR FIRE PREVENTION IN
"CUTTING & WELDING PROCESSES" BEFORE USING THIS PRODUCT.
Unusual Fire/Explosion Hazard:PRODUCT IS NON-FLAMMABLE & NON-EXPLOSIVE,
AS SHIPPED. WELDING ARCS & SPARKS CAN IGNITE COMBUSTIBLES &
INITIATE FIRES & EXPLOSIONS.
Spill Release Procedures:IF THE FUMES ARE REMOVED BY FILTRATION/SOME
OTHER MEANS & AIR/GAS STREAM IS PUT BACK INTO THE ROOM, GASES MAY
BUILD UP TO TOXIC OR ASPHYXIATION LEVELS. GAS BUILD-UP SHOULD BE
MONITORED & IF EXCESSIVE SHOULD BE REMOVED/REDUCED TO SAFE LEVELS.
====================== Handling and Storage ======================
Handling and Storage Precautions:ARCS PRODUCE ULTRAVIOLET/INFRARED
RADIATION. SMAW ELECTRODES ARE METAL CORE RODS COATED W/FLUX. AVOID
PHYSICAL ACCIDENTS. READ LABELS.
Other Precautions:TRAIN WELDER TO AVOID ELECTRIC SHOCK BY MAINTAINING A
DRY WORK AREA, INSULATING FROM THE WORKPIECE & GROUND. DON'T TOUCH
LIVE ELECTRICAL PARTS. PREVENT INJURY FROM RADIATION/SPARKS/&
ELECTRIC SHOCK. K EEP HEAD OUT OF WELDING PLUME.
Respiratory Protection:USE A FUME RESPIRATOR OR AIR SUPPLIED RESPIRATOR
WHEN WELDING IN CONFINED SPACES/WHERE VENTILATION IS INADEQUATE IN
MAINTAINING EXPOSURE
FUMES/GASES BY TAKI NG AN AIR SAMPLE FROM INSIDE HELMET.
Ventilation:USE ENOUGH VENTILATION, LOCAL EXHAUST AT THE ARC, OR BOTH
TO KEEP FUMES & GASES FROM THE WORKER'S BREATHING ZONE &
Protective Gloves:DRY WELDER'S GLOVES
Eye Protection:FACE SHIELD W/PROTECTIVE LENSES
Other Protective Equipment:ARM/SHOULDER PROTECTORS, APRONS, HATS,
WELDER'S HELMET. SEE SUPP FOR LENSE SHADE RECOMMENDATIONS.
Work Hygienic Practices:INGESTION OF MATERIAL IS POSSIBLE VIA DIRTY
HAND CONTACT W/FOOD & MOUTH.
Supplemental Safety and Health
START W/LENSE SHADE THAT IS TOO DARK TO SEE THE WELD ZONE. THEN GO TO A
LIGHTER SHADE (LOWER NUMBER SHADE) WHICH GIVE SUFFICIENT VIEW OF
THE WELD ZONE. OTHER COATING INGREDIENTS (R 20% BY WT) SUCH AS
OXIDES/FLUORIDES OF AL, BA, CA, MG, K, NA, SR, & TI. WELDING
PRODUCES CHEMICALS KNOWN TO CAUSE CANCER BY THESTATE OF CA.
Spec Gravity:7-9
Solubility in Water:INSOLUBLE
Appearance and Odor:BARE WIRE WELDING PRODUCTS ARE PRODUCED AS STRAIGHT
LENGTHS & COILED WIRES.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:CO/CO2/OZONE/OXIDES OF
NITROGEN/CHROMIUM II & III/NICKEL/COBALT/COPPER. WELDING
FUMES/GASES CANNOT BE EASILY CLASSIFIED.
Waste Disposal Methods:DISPOSE OF FUME, FLUX & WELD GRINDING RESIDUES
FROM THE WORK AREA, OR FROM FILTERS, IN ACCORDANCE W/LOCAL, STATE,
& FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.