MSDS NAME:KODALITH FINE LINE DEVELOPER PART A
NIIN:00-297-0991
MSDS Number: BBYBY
=== Responsible Party ===
Company:EASTMAN KODAK CO
Address:343 STATE ST
City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Info Phone Num:716-724-6481/716-722-5151
Emergency Phone Num:716-722-5151/716-724-4501
CAGE:19139
=== Contractor Identification ===
Company:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139
============= Composition/Information on Ingredients =============
Name:SODIUM FORMALDEHYDE BISULFITE
CAS:870-72-4
RTECS #:PB2200000
Fraction by Wt: 75-80%
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: UPPER RESPIRATORY TRACT
IRRITANT. EYES: MAY CAUSE IRRITATION. SKIN: PROLONGED/REPEATED
CONTACT MAY CAUSE IRRITATION. ALLERGIC REACTION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION
Medical Cond Aggravated by Exposure:SKIN ALLERGIES
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE FROM EXPOSURE, TREAT SYMPTOMATICALLY.
EYES/SKIN: FLUSH W/PLENTY OF WATER. WASH SKIN W/A NON-ALKALINE ACID
TYPE OF SKIN CLEANSER. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER SPRAY; DRY CHEMICAL; CO2
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA)
AND FULL PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:FIRE/EXCESSIVE HEAT MAY CAUSE PRODUCTION
OF HAZARDOUS DECOMPOSITION PRODUCTS.
Respiratory Protection:AN APPROPRIATE NIOSH-APPROVED RESPIRATOR FOR
DUST SHOULD BE WORN IF NEEDED.
Ventilation:LOCAL: IF NEEDED TO CONTROL DUST. MECH: RECOMMEND AT LEAST
10 AIR CHANGES PER HOUR FOR GOOD GENERAL ROOM VENTILATION.
Protective Gloves:PROTECTIVE
Eye Protection:SAFETY GLASSES
Work Hygienic Practices:REGULAR CLEANING OF WORK SURFACES & GLOVES WILL
MINIMIZE ALLERGIC SKIN REACTION.
Supplemental Safety and Health
PRODUCT HAS HIGH BIOLOGICAL OXYGEN DEMAND, CAUSES SIGNIFICANT OXYGEN
DEPLETION IN AQUATIC SYSTEMS. DILUTION TO FINAL CONCENTRATION OF
0.0025 MG/L EXPECTED TO CAUSE NO ADVERSE EFECT.
Waste Disposal Methods:DISCHARGE, TREATMENT/DISPOSAL MAY BE SUBJECT TO
FEDERAL, STATE/LOCAL LAWS. DILUTE W/LARGE AMOUNTS OF WATER,
FOLLOWED BY SECONDARY WASTE TREATMENT, PRODUCT IS NOT EXPECTED TO
HAVE ADVERSE ENVIRONMENTAL IMPACT.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.