MSDS   | : | NI-ROD FC 55 CORED WIRE | CAS   | : | 7789-75-5 7440-44-0 7439-89-6 7439-96-5 15096-52-3 7440-02-0 | NAME   | : | calcium fluoride, fluorspar, calcium difluoride, irtran 3, graphite, synthetic iron manganese (sara iii) cryolite, sodium aluminum fluoride, sodium fluoaluminate nickel (sara iii)
|
| |
|
|
===================== Product Identification =====================
MSDS NAME:NI-ROD FC 55 CORED WIRE
NIIN:00F019570
MSDS Number: BLQMM
=== Responsible Party ===
Company:INCO ALLOYS INTERNATIONAL INC
Address:1401 BURRIS RD
City:NEWTON
State:NC
ZIP:28658-1754
Info Phone Num:(704) 465-0352
Emergency Phone Num:(304) 526-5780
CAGE:9Z762
=== Contractor Identification ===
Company:INCO ALLOYS INTERNATIONAL INC
Address:1401 BURRIS RD
Box:City:NEWTON
State:NC
ZIP:28658-1754
Country:US
Phone:800-624-3411
CAGE:9Z762
============= Composition/Information on Ingredients =============
Name:CALCIUM FLUORIDE, FLUORSPAR, CALCIUM DIFLUORIDE, IRTRAN 3,
LIPARITE
CAS:7789-75-5
RTECS #:EW1760000
Fraction by Wt: 7-13%
Other REC Limits:2.5 MG/CUM (AS F)
OSHA PEL:2.5 MG/CUM (AS F)
ACGIH TLV:2.5 MG/CUM (AS F)
Name:GRAPHITE, SYNTHETIC
CAS:7440-44-0
RTECS #:FF5250100
Fraction by Wt: 1-5%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:2 MG/M3 TDUST; 9293
Name:IRON
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: 30-60%
Name:MANGANESE (SARA III)
CAS:7439-96-5
RTECS #:OO9275000
Fraction by Wt: 1-5%
OSHA PEL:(C) 5 MG/M3 DUST
ACGIH TLV:5 MG/M3 DUST 9293
Name:CRYOLITE, SODIUM ALUMINUM FLUORIDE, SODIUM FLUOALUMINATE
CAS:15096-52-3
RTECS #:WA9625000
Fraction by Wt: 1-5%
Name:NICKEL (SARA III)
CAS:7440-02-0
RTECS #:QR5950000
Fraction by Wt: 30-60%
Other REC Limits:1 MG/CUM
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9192
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION: ALLERGIC REACTIONS,
RESPIRATORY TRACT IRRITATION, & METAL FUME FEVER. SKIN: MECHANICAL
IRRITATION, & DERMATITIS. EYES: MECHANICAL IRRITATION, &
CONJUNCTIVITIS. INGESTION: GASTROINTESTINAL DISTRESS, VOMITING,
DIARRHEA, ABDOMINALPAIN, INTESTINAL BLOCKAGE, WILSON'S DISEASE, &
MANGANESE POISONING.
Explanation of Carcinogenicity:NICKEL IS AN A1 CARCINOGEN BY ACGIH.
Effects of Overexposure:INHALATION: ALLERGIC REACTIONS, RESPIRATORY
TRACT IRRITATION, & METAL FUME FEVER. EYES: MECHANICAL IRRITATION,
& CONJUNCTIVITIS. SKIN: MECHANICAL IRRITATION, & DERMATITIS.
INGESTION: GASTROINTESTINAL DISTRESS, VOMITING, DIARRHEA,
ABDOMINALPAIN, INTESTINAL BLOCKAGE, WILSON'S DISEASE, & MANGANESE
POISONING.
======================= First Aid Measures =======================
Eyes: FLUSH PARTICLES W/CLEAN WATER FOR AT LEAST 15 MIN.
SKIN: WASH W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. WATCH
FOR METAL FUME FEVER SYMPTOMS. INGESTION: OBTAIN MEDICAL ATTENTION
IN ALL CAS ES.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Unusual Fire/Explosion Hazard:SPARKS FROM WELDING IN USER OPERATIONS
COULD IGNITE FLAMMABLE OR COMBUSTIBLE LIQUIDS, VAPORS, & SOLIDS.
================== Accidental Release Measures ==================
Spill Release Procedures:VACUUM OR SHOVEL ANY SPILLED MATERIAL INTO A
SUITABLE CONTAINER. ALLOY WASTE ARE NORMALLY COLLECTED TO RECOVER
MATAL VALUES.
====================== Handling and Storage ======================
Other Precautions:USE INDUSTRIAL HYGIEN MONITORING TO INSURE THIS
MATERIAL DOES NOT EXCEED RECOMMENDED EXPOSURE LIMITS. FILLER METALS
MAY CONTAIN CHEMICALS SUBJECT TO SARA 313 REPORTING.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE AIR-SUPPLIED RESPIRATOR IN CONFINED SPACES.
USE ONLY NIOSH APPROVED IN ACCORDANCE W/29 CFR 1910.134.
Ventilation:LOCAL EXHAUST KEEP
Protective Gloves:REQUIRED
Eye Protection:REQUIRED
Other Protective Equipment:FACE PROTECTION, FLAME RETARDANT CLOTHING, &
RECOMMENDED LENS SHADE FROM AWS PUB F2.2
Supplemental Safety and Health
INGREDIENTS OF FUMES & GASES GENERATED IN WELDING OPERATIONS WILL
DEPEND ON ELECTRODE TYPE & ITS FLUX, BASE METAL & SPECIFIC PROCESS
BEING USED.
================== Physical/Chemical Properties ==================
Melt/Freeze Pt:M.P/F.P Text:>1832F
Spec Gravity:5-6 GM/CC
Appearance and Odor:METALLIC SILVER COLORED SOLID WIRE W/FLUX COATING
OR FLUX CORE, ODORLESS
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:METAL OXIDES, FLUORIDES, CO, OZONE,
NITROGEN OXIDE, & OTHER GASES
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|