Effects of Overexposure:INH:UNPLEASANT VAP;EYES:LIQ IRRITG;SKIN:ACUTE
CONTCT CAUSES IRRIT,ACUTE EXTENSVE SEE SUPP DATA
======================= First Aid Measures =======================
First Aid:INH:REMOVE FROM EXPOSURE.GIVE CPR/OXY IF NEEDED & GET MED
ATTN;EYES;FLUSH IMMED W/WATER FOR AT LEAST 15 MIN.GET MED
HELP;SKIN:FLUSH IMMED W/PLENTY OF WATER FOR 15 MIN.FOR IRRIT GET
MED ATTN.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:CO*2,DRY CHEM
Fire Fighting Procedures:USE SELF-CONTND BRTHG APP;COOL EXPSD CONT
W/WATER SPRAY.
Unusual Fire/Explosion Hazard:NONE KNOWN
Spill Release Procedures:EVACUATE UNPROTECTED PERSONS,PROVIDE
VENTILATION/SAFETY EQUIPMENTS IF NECESSARY.DIKE LG SOILL & PUMP
INTO COVERED CONTNRS;ABSORB SM SPILL W/ABSORBING MATL & PLACE IN
SAME CONTNR;MFR SUGGESTS FLUSH DOW N TO SEWER W/LG AMT OF H*2O IAW
EXISTING REGS.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AWAY FROM STRONG ALKALI.STORE IN
COOL DRY PLACE.KEEP CONTNRS TIGHTLY CLOSED.PROTECT CONTAINERS FROM
PHYSICAL DAMAGE.STORE BELOW 85F.
Other Precautions:AVOID SKIN/EYE CONTACT W/CHEMICAL PRODUCTS.WASH
THOROUGHLY AFTER HANDLING.PH APPROX:4.5
Respiratory Protection:AN APPRVD ORGANIC VAP RESPIRATOR FOR LARGE
VOLUME HANDLING.
Ventilation:LOCAL EXHAUST & MECHANICAL (GENERAL) RECOMMENDED BY MFR.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:AS NECESSARY TO PREVENT SKIN CONTACT.
Supplemental Safety and Health
MSDS FM MFR DATE:10-21-75;PER MFR,ITEM DISCONTD APPROX 1979;THIS DATA
FOR PART A OF 3 PART PRODUCT;OVER EXPOSR CONTD CONTACT CAUSES
SYSTEMICALLY TOXIC & RPEATD CONTACT MAY RESULT ALLERGY ACTN.
Waste Disposal Methods:KEEP IN COVERED CONTAINERS PENDING
DISPOSAL.DISPOSE IN FULL COMPLIANCE W/FEDERAL,STATE & LOCAL
REGULATIONS;MFR RECOMMENDS TO FLUSH DOWN TO SEWER W COPIOUS AMT
H*2O.STATE & LOCAL EFFLUENT LAWS TAKE PRE CEDENCE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.