MSDS   | : | MOBILMET S 126 | CAS   | : | 68608-26-4 61790-50-9 8050-09-7 8002-33-3 7664-38-2 107-41-5 64742-52-5 64742-65-0 | NAME   | : | sodium petroleum sulfonate; (sulfonic acids, petroleum, resin acids and rosin acids, potassium salts rosin acid; (rosin) turkey-red oil; (castor oil, sulfated) phosphoric acid 2,4-pentanediol, 2-methyl-; (hexalene glycol) mineral oil, petroleum distillates, hydrotreated heavy mineral oil, petroleum distillates, solvent-dewaxed heavy
|
| |
|
|
===================== Product Identification =====================
MSDS NAME:MOBILMET S 126
NIIN:00N023294
MSDS Number: BMFFN
=== Responsible Party ===
Company:MOBIL OIL CORP
Address:3225 GALLOWS RD
City:FAIRFAX
State:VA
ZIP:22037
Country:US
Info Phone Num:800-662-4525
Emergency Phone Num:212-883-4411;800-424-9300(CHEMTREC)
Preparer's Name:ENVIRON AFFAIRS/TOX DEPT
CAGE:1E969
=== Contractor Identification ===
Company:MOBIL OIL CORP
Address:530 EAST SWEDESFORD ROAD
Box:1031
City:VALLEY FORGE
State:PA
ZIP:19482
Country:US
Phone:703-849-3265
CAGE:1E969
Company:MOBIL OIL CORP ENVIRONMENTAL AFFAIRS & TOXICOLOGY
Address:PENNINGTON-ROCKY HILL RD
Box:City:PENNINGTON
State:NJ
ZIP:08534
Country:US
CAGE:0AHK0
============= Composition/Information on Ingredients =============
Name:SODIUM PETROLEUM SULFONATE; (SULFONIC ACIDS, PETROLEUM,
SODIUM SALTS)
CAS:68608-26-4
RTECS #:WR7150000
Fraction by Wt: <9%
OSHA PEL:5 MG/M3 AS OIL MIST
ACGIH TLV:5 MG/M3 AS OIL MIST
Name:RESIN ACIDS AND ROSIN ACIDS, POTASSIUM SALTS
CAS:61790-50-9
Fraction by Wt: <5%
Name:ROSIN ACID; (ROSIN)
CAS:8050-09-7
Fraction by Wt: <5%
Name:TURKEY-RED OIL; (CASTOR OIL, SULFATED)
CAS:8002-33-3
RTECS #:YO8300000
Fraction by Wt: <2%
Name:PHOSPHORIC ACID
CAS:7664-38-2
RTECS #:TB6300000
Fraction by Wt: 0.09%
OSHA PEL:1 MG/M3;3 PPM STEL
ACGIH TLV:1 MG/M3;3 PPM STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:2,4-PENTANEDIOL, 2-METHYL-; (HEXALENE GLYCOL)
CAS:107-41-5
RTECS #:SA0810000
OSHA PEL:25 PPM, C
ACGIH TLV:25 PPM, C
Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED HEAVY
NAPHTHANIC
CAS:64742-52-5
RTECS #:PY8035000
Fraction by Wt: >75%
Name:MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-DEWAXED HEAVY
PARAFFINIC
CAS:64742-65-0
RTECS #:PY8038500
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50: (ORAL,RAT) > 5 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SLIGHT EYE IRRITATION. SLIGHT SKIN
IRRITATION.
Explanation of Carcinogenicity:CAS NO. 64742-65-0 AND 64742-52-5: GROUP
1 (IARC).
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH W/WATER FOR AT LEAST 15 MIN.SKIN:WASH CONT AREAS
W/SOAP & WATER.INHAL:REMOVE FROM FURTHER EXPOS.IF UNCON OCCURS,SEEK
MD.IF BRTHG STOPS,USE MOUTH TO MOUTH RESUSCITATION.INGEST:NOT
EXPECTED TO BE A PROBLEM.HOWEVER, IF >1/2 LITER (PINT) INGESTED,
IMMED GIVE 1 TO 2 GLASSES OF WATER & CALL MD, HOSPITAL EMER
ROOM/POIS CONTROL CTR.DO NOT INDUCE VOMIT/GIVE ANYTHING BY MOUTH TO
UNCON PERSON.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:>380F,>193C
Lower Limits:0.6%
Upper Limits:7.0%
Extinguishing Media:CO*2, FOAM, DRY CHEMICAL AND WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
.WATER/FOAM MAY CAUSE FROTHING.USE WATER TO KEEP FIRE EXPSD CNTNRS
COOL.WATER SPRAY MAY BE USED (SUPP DATA)
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED SAWDUST,
DIATOMACEOUS EARTH, ETC. SHOVEL UP & DISPOSE OF AT APPROP WASTE
DISP FAC I/A/W CURRENT APPLIC LAWS & REGS & PROD CHARACT AT TIME OF
DISP.US COAST GUARD REGS R EQ IMMED RPTG OF SPILLS THAT COULD
(SEESUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:EMPTY CONTAINERS MAY CONTAIN PRODUCT RESIDUE,
INCLUDING FLAMMABLE OR EXPLOSIVE VAPORS. DO NOT CUT, PUNCTURE OR
WELD ON OR NEAR CONTAINER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NO SPECIAL REQUIREMENTS UNDER ORDINARY
CONDITIONS OF USE AND WITH ADEQUATE VENTILATION. NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:USE IN WELL VENTILATED AREA. PROVIDE ADEQUATE LOCAL
VENTILATION WHEN TLV IS EXCEEDED.
Protective Gloves:NO SPECIAL EQUIPMENT REQUIRED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS
BE FOLLOWED.
Supplemental Safety and Health
FIRE FIGHT PROC:TO FLUSH SPILLS AWAY FROM EXPOS.PVNT RUNOFF FROM FIRE
CONTROL/DILUTION FROM ENTERING STREAMS/DRINKING WATER SUPPLY.SPILL
PROC:REACH ANY WATERWAY INCLUDING INTERMITTENT DRY CREEKS.
================== Physical/Chemical Properties ==================
HCC:V6
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:<0.1 @ 20C
Vapor Density:0.931
Solubility in Water:EMULSIFIES
Appearance and Odor:LIQUID WITH A MILD ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:CO.
==================== Disposal Considerations ====================
Waste Disposal Methods:EMULSION MAY BE BROKEN BY ADDING ALKALI, THE
SOLIDS FILTERED OFF & EITHER BURNED/DISPOSED OF AT AN APPROP WASTE
DISP FAC I/A/W CURRENT APPLIC LAWS & REGS & PROD CHARACT AT TIME OF
DISP. DISP MUST BE I /A/W FEDERAL, STATE & LOCAL REGS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|
ALL PAGES On Chemical Property IN THIS GROUP
| NAME | CAS |
CEMENT - 002 REGULAR CLEAR PVC SOLVENT (SUP
| 9002-86-2 109-99-9 67-64-1 78-93-3 108-94-1 |
CEMENT - 002 REGULAR CLEAR PVC SOLVENT (SUP
| 9002-86-2 109-99-9 67-64-1 78-93-3 108-94-1 |
CEMENT - 002 REGULAR CLEAR PVC SOLVENT (SUP
| 9002-86-2 109-99-9 67-64-1 78-93-3 108-94-1 |
CEMENT - 002 REGULAR CLEAR PVC SOLVENT (SUP
| 9002-86-2 109-99-9 67-64-1 78-93-3 108-94-1 |
DESIGN COATS, DN829
| 1317-36-8 14808-60-7 |
DESIGN COATS, DN830
| 1317-36-8 14808-60-7 |
DESIGN COATS, DN831
| 1317-36-8 14808-60-7 |
DESIGN COATS, DN833
| 1317-36-8 14808-60-7 |
BLOOMGARDEN EASY DO, 238123
| 68412-54-4 111-76-2 75-21-8 |
BLOOMGARDEN SCRUB A DO, 28121
| 111-76-2 25155-30-0 75-21-8 |
BLOOMGARDEN DO IT ALL, 28128
| 111-76-2 25155-30-0 75-21-8 |
BLOOMGARDEN WHAT'S IT DO, 28120
| 7632-00-0 6834-92-0 |
BLOOMGARDEN DO DO, 28118
| 64742-47-8 7758-29-4 151-21-3 25155-30-0 75-21-8 |
CALIBRATION GAS, 463464
| 74-82-8 7782-44-7 7727-37-9 |
PULL WIRE FUSE LIGHTER
| 7723-14-0 |
REGULAR 30
| |
MOBIL FLUID 423
| |
MOBILGEAR 626
| |
MOBILGREASE CM-S
| 4485-12-5 1330-20-7 7440-66-6 |
MOBILMET OMICRON
| |
MOBILMET S 126
| 68608-26-4 61790-50-9 8050-09-7 8002-33-3 7664-38-2 107-41-5 64742-52-5 64742-65-0 |
MOTREX 651
| |
NO 5 FUEL OIL
| 64741-62-4 68410-00-4 |
X-CEL PLUS HI-WEAR/HI-GLOSS FLOOR FINISH, 1
| 63744-68-3 9010-77-9 68441-17-8 115-77-5 111-77-3 7732-18-5 |
NICKEL SULFAMATE CONCENTRATE
| 13770-89-3 |
CORVEL COATING POWDER, 10-7004
| 63231-67-4 7727-43-7 |
SAFE-T-SALT
| 7647-14-5 |
ROOF FIX ROOF CEMENT ASPHALT COMPOUND
| 64741-44-2 |
1-PHENYL-2-AMINOPROPANE HCL
| 2706-50-5 |
AEROSOL SPRAY PAINT, 0487 MODERN FLAT BLACK
| 64742-88-7 64742-89-8 75-09-2 74-98-6 1333-86-4 64742-48-9 14807-96-6 75-28-5 |
NICKEL CHROMIUM, ALUMINUM/BENTONITE COMPOSI
| 7440-02-0 7440-47-3 7429-90-5 1302-78-9 |
NICKEL CHROMIUM, ALUMINUM/BENTONITE COMPOSI
| 7440-02-0 7440-47-3 7429-90-5 1302-78-9 |
WOOD FINISH JACOBEAN NO 2750, 21142
| 8052-41-3 |
VENTILATION SMOKE TUBE KIT, 458481
| 64-19-7 63231-67-4 107-15-3 1332-09-8 |
COBALT MOLYBDENUM CHROMIUM ALLOY POWDER, 66
| 7440-21-3 7439-98-7 7440-48-4 7440-02-0 7440-47-3 |
COBALT MOLYBDENUM CHROMIUM ALLOY POWDER, 68
| 7440-21-3 7439-98-7 7440-48-4 7440-02-0 7440-47-3 |
SODIUM BICARBONATE
| 144-55-8 |
BUFFER MIXTURE (ONE OF TWO REAGENTS), 10044
| 10101-89-0 7558-80-7 |
REAGENT SOLUTION FOR CYANIDE (SECOND OF (SU
| 127-65-1 110-86-1 7732-18-5 |
ULD BP-100 INSECTICIDE, 04961-04965
| 8003-34-7 51-03-6 463-04-7 64742-14-9 |
R-300 3% MULTIPURPOSE SPRAY FORMULA WITH (S
| 10453-86-8 64742-47-8 |
1530 BIG BLAST
| 124-38-9 71-55-6 628-63-7 |
REG HOT DIP-RACK, E1003
| 117-81-7 |
TRICHLOROTRIFLUOROETHANE & ISOPROPYL ALCOHO
| 67-63-0 76-13-1 |
HYDRION INDICATOR SOLUTIONS
| 7732-18-5 67-63-0 25322-68-3 76-59-5 845-10-3 76-61-9 |
MICAPLY EG-150 LAMINATE
| 65997-17-3 7440-50-8 |
HURRI-SAFE ALL PURPOSE CLEANER
| 111-76-2 |
HURR-SAFE 301 DISCHARGE ADDITIVE (NEUTRALIZ
| 64-19-7 |
HURRI-SAFE WASTE WATER ADDITIVE
| 111-76-2 |
HURRI-SAFE FORMULA 301 DEGREASER
| 111-76-2 |
|
|