LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: IRRITATES SKIN & EYES.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:SENSITIVE SKIN.
======================= First Aid Measures =======================
First Aid:INHAL:NOT APPLICABLE IN NORMAL OPERATION. EYE:FLUSH
THOROUGHLY W/FRESH WATER FOR AT LEAST 15 MINS. GET MEDICAL
ATTENTION. SKIN:FLUSH W/FRESH WATER. WASH W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHES & S HOES. INGEST:GIVE MILK OR WATER. DO
NOTINDUCE VOMITING. GET MEDICAL ATTENTION. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:CO*2 & DRY CHEMICALS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . KEEP COOL.
Unusual Fire/Explosion Hazard:HIGH TEMPERATURE WILL RELEASE CL*2.
Spill Release Procedures:FLUSH SMALL AMOUNTS TO DRAIN. COLLECT & RETURN
LARGE AMOUNTS TO CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP FROM FREEZING. KEEP CONTAINER
CLOSED. IF FROZEN, THAW & MIX TO MAKE USUABLE. DO NOT PRESSURE
CONTAINER TO EMPTY.
Other Precautions:VOLUNTARY; CAUTION ON CONTAINER LABEL. DO NOT GET IN
EYES, ON SKIN OR CLOTHING .
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:PRODUCING NORMAL AIR DILUTION.
Protective Gloves:NON-ABSORBENT GLOVES.
Eye Protection:CHEM WORK GOGGS/FULL LENGTH (SUPP DATA)
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EYE PROT:FACESHIELD WHEN HANDLING.
Waste Disposal Methods:PH ADJUSTMENT; NO PHOSPHORUS, PHENOLS OR HEAVY
METAL IONS. USE UNTIL < 1 INCH REMAINS IN CONTR. EMPTY CONTR.
TRIPLE RINSE W/WATER. ADD TO OPERATION. REMOVE/DEFACE LBL BEFORE
SELLING CONTR/DISP. DISP M UST BE I/A/W FED, STATE & LOCAL REGS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,