LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:(ACUTE) OVEREXPOSURE BY INHALATION MAY
CAUSE IRRITATION OF THE RESPIRATORY TRACT, HEADACHE, DIZZINESS, OR
DROWSINESS. SKIN/EYE: IRRITANT TO EYES AND SKIN. (CHRONIC) THOSE
HAZARDOUS MATLS MAY AFFECT TH E FOLLOWING ORGANS: RESP TRACT, CNS,
KIDNEYS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.TOLUENE, CAS NO. 108-88-3
APPEARS ON THE NAVY LISTING OF OCCUPATIONAL REPRODUCTIVE HAZARDS.
SEEK CONSULTATION FROM APPROPRIATE HEALTH PROFESSIONALS CONCERNING
LATEST HAZARD LIST INF ORMATION AND SAFE HANDLING AND
EXPOSURERECOMMENDATIONS .
Medical Cond Aggravated by Exposure:UNKNOWN AT THIS TIME.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE FROM EXPOSURE. EYE: FLUSH IMMEDIATELY WITH
LARGE AMOUNTS OF RUNNING WATER FOR AT LEAST 15 MINUTES. SKIN:
REMOVE CONTAMINATED CLOTHING AND WASH SKIN WITH SOAP AND WATER.
INGEST: DRINK WAT ER. IF NECESSARY, CONSULT MD FOR ANY OFTHESE
CONDITIONS.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:26.0F,-3.3C
Lower Limits:1.05%
Extinguishing Media:USE WATER FOG, FOAM, DRY CHEMICAL, OR CO2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, AVOID
BREATHING VAPORS. VENT AREA AND REMOVE WITH INERT ABSORBENT AND
NON- SPARKING TOOLS. DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE
AND LOCAL REGULATIONS. BEFORE AT TEMPT CLEANUP, SEE INGRED SECTION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT TAKE INTERNALLY. CNTNRS SHOULD
BE GROUNDED WHEN POURING. AVOID FREE FALL OF LIQ IN EXCESS OF FEW
INCHES.
Other Precautions:MAKE SURE DRUM IS COMPLETELY EMPTY BEFORE ATTEMPTING
TO WELD OR BRAZE. THE DRUM SHOULD BE INDUSTRIALLY CLEANED PRIOR TO
REUSE. DO NOT FLAME CUT, BRAZE, OR WELD WITHOUT A NIOSH/MSHA
APPROVED RESPIRATOR OR APPROPRIATE VENTILATION.
Respiratory Protection:WHERE GENERAL DILUTION/LOC EXHST FAILS TO ADEQ
DILUTE TWA/PEL OF MATL, THEN RESP PROT SHOULD BE USED AS FOLLOWS:
I/A/W 29CFR 1910.134, USE NIOSH/MSHA APPRVD AIR LINE TYPE
RESP/HOODS FOR ENCLSD & CONFI NED AREAS. NIOSH/MSHA APPRVD (SUPP
DATA)
Ventilation:PROVIDE GENERAL DILUTION/LOCAL EXHAUST VENTILATION TO KEEP
TWA AND LEL BELOW ACCEPTABLE LIMITS & TO REMOVE DECOMP PRODS.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
RESP PROT: AIR PURIFYING RESPIRATORS MAY BE USED FOR OTHER AREAS.
HCC:F3
Boiling Pt:B.P. Text:172F,78C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.51
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES MAY CONTAIN CO & OXIDES OF
NITROGEN. MAY PRODUCE HAZ FUMES WHEN HEATED TO DECOMP AS IN
WELDING.
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.