===================== Product Identification =====================
MSDS NAME:JP-4 (AVIATION GRADE TURBINE FUEL)
NIIN:01-305-5596
MSDS Number: BNCMX
=== Responsible Party ===
Company:CALCASIEU REFINING CO.
Address:WEST END OF TANK FARM ROAD
City:LAKE CHARLES
State:LA
ZIP:70606
Country:US
Info Phone Num:318-478-2130
Emergency Phone Num:318-478-2130/800-535-5053(INFOTRAC)
CAGE:CALCA
=== Contractor Identification ===
Company:CALCASIEU REFINING CO.
Address:WEST END OF TANK FARM ROAD
Box:City:LAKE CHARLES
State:LA
ZIP:70606
Country:US
Phone:318-478-2130
CAGE:CALCA
============= Composition/Information on Ingredients =============
Name:HYDROCARBONS (TOTAL)
Fraction by Wt: MIXTURE
Other REC Limits:NONE SPECIFIED
Name:BENZENE (SARA III)
CAS:71-43-2
RTECS #:CY1400000
Fraction by Wt: 0.5-1.5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:1PPM/5STEL;1910.1028
ACGIH TLV:10 PPM; A2; 9192
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 0.8-1.8%
Other REC Limits:NONE SPECIFIED
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 1.0-2.0%
Other REC Limits:NONE SPECIFIED
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:CYCLOHEXANE (SARA III)
CAS:110-82-7
RTECS #:GU6300000
Fraction by Wt: 0.5-1.5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:300 PPM
ACGIH TLV:300 PPM, 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:TYPICAL PETROLEUM HYDROCARBON IN THIS
BOILING RANGE MAY CAUSE IRRITATION TO THE EYES, LUNGS OR SKIN AFTER
PROLONGED OR REPEATED EXPOSURE. PROMPT REMOVAL OF THIS PRODUCT
SHOULD PREVENT ANY CHRONIC HEAL TH PROBLEMS. ALSO, AVOID BREATHING
OF THE VAPORS.
Explanation of Carcinogenicity:BENZENE IS A LISTED CARCINOGEN BY OSHA,
IARC & NTP.
Effects of Overexposure:SOME STUDIES HAVE INDICATED THAT WORKERS
EXPOSED MANY YEARS TO HIGHER CONCENTRATIONS OF BENZENE HAVE A
SLIGHTLY HIGHER INCIDENCE OF LEUKEMIA. HOWEVER, DUE TO THE LOW
LEVELS OF BENZENE IN THIS MATERIAL , PROPER HANDLING SHOULD
MINIMIZE ANY POTENTIAL HEALTH PROBLEMS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHALATION-REMOVE TO FRESH AIR. IF BREATHING DIFFICULT, GIVE
OXYGEN. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. CALL A
PHYSICIAN. SKIN-IMMEDIATELY WASH WITH SOAP AND WATER. CHANGE
CLOTHING. EYE-IM MEDIATELY FLUSH WITH WATER. CALL PHYSICIAN.
INGESTION-DO NOT INDUCE VOMITING. GIVE TWO GLASSES OF WATER, IF
CONSCIOUS. CALL PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:<10F,<-12C
Lower Limits:1.3%
Upper Limits:8.0%
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WATER COULD BE USED, BUT MAY BE INEFFECTIVE
EXCEPT TO KEEP EXPOSED CONTAINERS COOL. CAN ALSO BE USED TO
DISPERSE IF UNIGNITED.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE AS REQUIRED. REMOVE SOURCES OF HEAT,
SPARKS, ETC. ATTEMPT TO ISOLATE SPILL AND KEEP FROM ENTERING SEWERS
OR WATERWAYS. RECOVER FREE LIQUID FOR RECLAMATION.
====================== Handling and Storage ======================
Handling and Storage Precautions:WEAR PROTECTIVE GLOVES (NEOPRENE OR
NBR). WEAR SAFETY GLASSES WITH SIDE SHIELDS OR, IF SPLASHING IS
PROBABLE, WEAR CHEMICAL GOGGLES.
Other Precautions:NOTE: REVIEW APPROPIATE SAFETY SECTIONS OF THIS MSDS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:AVOID BREATHING VAPORS. IF A SITUATION EXISTS
FOR THE THE POTENTIAL OF EXCEEDING EXPOSURE LIMITS, DETERMINE
WHETHER AN ORGANIC VAPOR CARTRIDGE WILL SUFFICE OR WETHER POSITIVE
PRESSURE BREATHING EQUIPM ENT WILL BE REQUIRED.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:NEOPRENE OR NITRILE RUBBER GLOVES
Eye Protection:SAFETY GLASSES - CHEMICAL SPLASH GOGGLES
Other Protective Equipment:HAVE EMERGENCY EYE WASH AND SAFETY SHOWER
AVAILABLE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING.
Supplemental Safety and Health
RQ BENZENE: 10 LBS.
================== Physical/Chemical Properties ==================
HCC:F2
Boiling Pt:B.P. Text:100F,38C
Vapor Pres:2.7 PSIA
Vapor Density:>1
Spec Gravity:0.75-0.77
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR TO LIGHT STRAW COLOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:AVOID HEAT, SPARKS OR BUID-UP OF STATIC
ELECTRICITY.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:SOAK UP WITH AN ABSORBENT MATERIAL. THIS
MATERIAL MAY BE A RCRA HAZARDOUS WASTE AND, IF SO, MUST BE HANDLED
ACCORDING TO APPLICABLE REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|
ALL PAGES On Chemical Property IN THIS GROUP
| NAME | CAS |
10% NEUTRAL BUFFERED FORMALIN,V/V
| 50-00-0 67-56-1 |
TAN 686A ZENTHASELF-CONTAINED BREATHING APP
| 110-12-3 13463-67-7 1332-37-2 14808-60-7 108-10-1 1330-20-7 7440-47-3 123-86-4 822-06-0 |
TAN 686A ZENTHATNE, PC 08609TUY
| 110-12-3 13463-67-7 1332-37-2 14808-60-7 108-10-1 1330-20-7 7440-47-3 123-86-4 822-06-0 |
INSTANT BOND #123
| 708-85-0 |
AVIATION TURBO FUEL (HIGH FLASH)
| |
H9728(FM) NICAD BATTERY,SEALED
| 1310-58-3 7440-02-0 12054-48-7 21041-93-0 1310-66-3 |
1-K KEROSENE
| 8008-20-6 |
00711 PENETRANT LUBRICANT, AEROSOL
| 111-76-2 64475-85-0 25496-72-4 64741-97-5 25619-56-1 64741-88-4 74-98-6 |
VICTREX PEEK 450GL30, 764-030-000
| 29658-26-2 65997-17-3 |
SHELL JET A-1 47
| 64742-81-0 |
BP OIL
| 8008-20-6 |
004O6 AVJET A
| 8008-20-6 71-43-2 |
TURBO FUEL A
| 64742-47-8 |
JET A KEROSINE
| 8008-20-6 |
PHILJET A WITH PFA 55 MB
| 111-65-9 111-84-2 71-43-2 108-88-3 106-42-3 108-38-3 95-47-6 108-67-8 95-63-6 526-73-8 109-86-4 |
00410 AVJET A
| 8008-20-6 |
JET A
| 8008-20-6 91-20-3 |
JET FUEL JP-4
| 108-88-3 1330-20-7 100-41-4 71-43-2 110-82-7 1634-04-4 |
JET FUEL, JP-4
| 71-43-2 1330-20-7 |
JP-4 (AVIATION GRADE TURBINE FUEL)
| 71-43-2 108-88-3 1330-20-7 110-82-7 |
ESSO MARINE GAS OIL
| |
EPOXY PART A, MIL-C-22750E GLOSS, M0-082
| 78-93-3 25085-99-8 108-88-3 |
ACTIVATOR PART B, MIL-C-22750E, BLACK 17038
| 108-88-3 78-93-3 25154-52-3 1477-55-0 68738-77-2 14464-46-1 14808-60-7 |
EPOXY PART A, MIL-C-22750E GLOSS, M1-048
| 108-88-3 25085-99-8 68609-97-2 78-93-3 14464-46-1 14807-96-6 |
ACTIVATOR PART B, MIL-C-22750E, GREEN 24533
| 25154-52-3 1477-55-0 68738-77-2 78-93-3 14464-46-1 1308-38-9 8007-18-9 13463-67-7 64742-95-6 108-88-3 67-56-1 108-83-8 13463-67-7 7440-50-8 |
FORM-A-GASKET SILICONE BLUE RTV 80627
| 9016-00-6 112945-52-5 4253-34-3 |
P-CYANOPHENOL
| 767-00-0 |
SILICONE SYSTEMS 982
| |
SILICONE SYSTEMS 982
| |
NORSIL RTV 138
| |
R3510 COPPER CHEMETS, VACUETTES AND VACU-VI
| 4733-39-5 144-62-7 7631-90-5 67-64-1 64-19-7 1336-21-6 7732-18-5 |
R3510 COPPER CHEMETS, VACUETTES AND VACU-VI
| |
1129 TITAN LUBE
| |
V60RT,RECHARGEABLE BATTERY
| 12054-48-7 1310-58-3 7440-02-0 |
02112 URSA SUPER PLUS SAE 30
| 64742-65-0 |
RPM HEAVY DUTY MOTOR OIL SAE 30
| 64742-54-7 64742-65-0 |
DELO HEAVY DUTY MOTOR OIL SAE 30
| 85-68-7 68649-42-3 |
02112 URSA SUPER PLUS SAE 30
| 64742-65-0 |
XD-3 30
| 64742-54-7 |
DELO HEAVY DUTY MOTOR OIL SAE 30
| 85-68-7 68649-42-3 |
02109 URSA SUPER PLUS SAE 15W-40
| 64742-65-0 |
RPM HEAVY DUTY MOTOR OIL SAE 15 W-40
| 64742-54-7 64742-65-0 |
02109 URSA SUPER PLUS SAE 15W-40
| 64742-65-0 |
XD-3 15W-40
| 64742-54-7 64742-54-7 64742-65-0 |
DELO MULTIGRADE HEAVY DUTY MOTOR OIL SAE 15
| 85-68-7 68649-42-3 |
02109 URSA SUPER PLUS SAE 15W-40
| 64742-65-0 |
CHEVRON RPM HEAVY DUTY MOTOR OIL SAE 15W-40
| 64742-54-7 64742-65-0 68649-42-3 |
02112 URSA SUPER PLUS SAE 30
| 64742-65-0 |
RPM HEAVY DUTY MOTOR OIL SAE 30
| 64742-54-7 64742-65-0 |
DELO HEAVY DUTY MOTOR OIL SAE 30
| 85-68-7 68649-42-3 |
|
|