supdat:& may ignite explo. during use & until all vaps are ing 6:or pilot lights/heaters, turn off stoves/elec tools & ing 7:code. use apprvd bonding/grounding procs. keep cntnr ing 8:w/complete & approp lbling. do not take internally. ing 9:matls classified as nuisance particulates, for ex ing 10:present @ haz levels only during sanding/abrading ing 11:before use. before opening packages, read & follow resp prot:direction for use. wear resp for whole time of ing 13:should be allowed in area where prod is being used vent:1910.94, 1910.107, 1910.108. ethyl alcohol; (ethanol). vp:44 2-butanone; (methyl ethyl ketone). vp:70 cyclohexanone (sara iii). vp:2 acetic acid, butyl ester; (n-butyl acetate) (sara iii). acetic acid, 2-methoxy-1-methyl ethyl;
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:OVEREXP CAUSES EYE, SKIN & RESP
IRRIT. MAY CAUSE NERV SYS DEPRESS ACCOMPANIED BY HDCH, DIZZ, NAUS,
CONFUSN & STAG GAIT. EXTREME OVEREXP MAY RESULT IN UNCON & POSS
DEATH. MAY CAUSE ALLERGIC RESP &/OR SKIN RXN IN SUSCEPTIBLE
PERS/SENSIT. EFT MAY BE DELAYED SEVERAL HRS AFTER EXPOS.
CHRONIC:MEK MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INCR NERV SYS EFTS OF OTHER SOLVS.
PRLNG OVEREXP MAY CAUSE ADVERSE EFTS TO LIVER, URINARY, BLOOD
FORMING & REPRO SYS. PERS SENSITIVE TO ISOCYANATES WILL EXPER INCR
ALLERGIC RXN ON RPTD EXPOS. REPORTS HAVE ASSOC RPTD & PRLNG
OVEREXP TO SOLVS W/PERM BRAIN & NERS SYS DMG. INTENT MISUSE BY
DELIB CONC & (SUPDAT)
Medical Cond Aggravated by Exposure:CHRONIC (LONG-TERM) LUNG OR
BREATHING PROBLEMS.
======================= First Aid Measures =======================
First Aid:INHAL:IF ANY BRTHG PROBS OCCUR DURING USE, LEAVE AREA & GET
FRESH AIR. IF PROBS REMAIN/OCCUR LATER, IMMED GET MD. SKIN:WASH
AFFECTED AREA THORO W/SOAP & WATER. REMOVE CONTAM CLTHG & LAUNDER
BEFORE RE- USE. EYES:FLUSH W/LG AMTS OF WATER FOR AT LEAST 15
MINUTES. GET MD. INGEST:CALL MD IMMEDIATELY .
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:20.0F,-6.7C
Lower Limits:1.1%
Extinguishing Media:CO2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
H2O SPRAY MAY BE INEFT. IF H2O IS USED, FOG NOZZ ARE PREF. H2O MAY
BE USED TO COOL CLSD CNTNRS TO(SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. APPLICATN TO HOT SURFS (SUPDAT)
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NO PERS SHLD USE PROD/BE IN AREA WHERE
IT IS BEING USED, IF THEY HAVE CHRONIC (LONG-TERM) LUNG/BRTHG
PROBS/IF THEY EVER HAD RXN TO ISOCYANATES.
Other Precautions:USE ONLY W/ADEQ VENT. AVOID BRTHG VAP/SPRAY MIST.
AVOID CONT W/SKIN/EYES. PROT AGAINST DUST WHICH MAY BE GEN BY
SANDING/ABRADING DRIED FILM. CONTENTS ARE EXTREMELY FLAMM. KEEP
AWAY FROM HEAT, SPKS/OPE N FLAME. VAPS WILL ACCUM READILY (ING 6)
Respiratory Protection:WHERE OVERSPRAY IS PRESENT, A NIOSH/MSHA APPRVD
POS PRESS AIR SUPPLIED RESP (TC19C) IS RECOM. IF UNAVAIL, WEAR A
NIOSH/MSHA APPRVD VAP/PARTICULATE RESP WHICH RESP MFR RECOMS AS
EFTIVE FOR ISOCYANATE V AP/MIST. FOLLOW RESP MFR'S (ING 13)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS TO MATLS IS
MAINTAINED BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS(ING 15)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:USE BARRIER CREAM ON EXPOSED SKIN.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:COATING CLEAR. FIRE FIGHT:PVNT PRESS BUILD-UP
& POSS AUTOIGNIT/EXPLO WHEN EXPOS TO EXTREME HEAT. EXPLO HAZ:REQS
SPECIAL PRECS. DURING EMER CNDTNS OVEREXP TO DECOMP PRODS MAY C
AUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT. GET MD. EFTS OF
OVEREXP:INHAL CONTENTS CAN BE HARMFUL/FATAL.
HCC:F3
Boiling Pt:B.P. Text:>172F,>78C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.0
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:84.3
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CO2, CO, NOX, POSSIBILITY OF
HYDROGEN CYANIDE.
Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERM APPLIC
EPA HAZ WASTE NUMBERS. INCIN IN APPRVD FACILITY. DO NOT INCIN CLSD
CNTNR. DISP OF I/ A/W FED, STATE & LOC REGS REGARDING POLLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.