LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATES EYES, SKIN, NOSE AND THROAT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:MOVE FROM EXPOSURE. GET MD IMMEDIATELY. EYE:FLUSH WITH
COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SKIN:REMOVE ANY
CONTAMINATED CLOTHING. FLOOD SKIN WITH LARGE VOLUMES OF WATER FOR
15 MINU TES. INGEST:CALL MD IMMEDIATELY.
===================== Fire Fighting Measures =====================
Extinguishing Media:NON-FLAMMABLE. USE WATER, CARBON DIOXIDE, DRY
CHEMICAL EXTINGUISHING AGENTS, DRY SAND OR DRY GROUND DOLOMITE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . IF WITHOUT RISK, REMOVE MATERIAL FROM FIRE
AREA. COOL CONTAINER WITH WATER FROM MAX DISTANCE.
Unusual Fire/Explosion Hazard:NONE KNOWN.
Spill Release Procedures:WEARING FULL PROTECTIVE CLOTHING & NIOSH/MSHA
APPROVED RESPIRATORY PROT, ELIM ALL SOURCES OF IGNITION. COVER
SPILL WITH DRY SAND OR DRY VERMICULITE, MIX WELL & CAREFULLY
TRANSFER TO A WELL-MARKED CNTN R. CLOSE CNTNR TIGHTLY. SUBMIT OR
RETAIN FOR DISP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:PROTECT FROM LIGHT. KEEP CONTAINER
TIGHTLY CLOSED. STORE IN A COOL, DRY, WELL-VENTILATED AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
HCC:N1
Boiling Pt:B.P. Text:DECOMPOSES
Melt/Freeze Pt:M.P/F.P Text:424F,218C
Spec Gravity:0.77
Solubility in Water:INSOLUBLE
Appearance and Odor:YELLOW TO OLIVE GREEN POWDER
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Stability Condition to Avoid:LIGHT.
Hazardous Decomposition Products:CO, CO*2, SILVER OXIDE FUMES.
Waste Disposal Methods:CONSULT STATE, LOCAL AND FEDERAL REGULATIONS FOR
DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.