LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HARMFUL IF INHALED OR SWALLOWED.
CAUSES IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes: TREAT BY IMMEDIATE AND PROLONGED IRRIGATION WITH
COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SEEK MEDICAL
ADVICE. SKIN: FLUSH WITH WATER. INHALATION: REMOVE TO FRESH AIR. IF
NOT BREATHING GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS
DIFFICULT, GIVE OXYGEN. INGESTION: WASH OUT MOUTH WITH WATER
PROVIDED PERSON IS CONSCIOUS. CALL PHYSICIAN.
===================== Fire Fighting Measures =====================
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE TO SURROUNDING
FIRE CONDITIONS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES UNDER FIRE CONDITIONS.
Spill Release Procedures:SWEEP UP, PLACE IN A BAG AND HOLD FOR WASTE
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:AVOID CONT & INHAL.WASH THORO AFTER HNDLG.IRRIT.
HARMFUL SOLID.HARMFUL BY INHAL, IN CONT W/SKIN & IF SWALLOWED.
IRRIT TO EYES, RESP SYS & SKIN.IN CASE OF CONT W/EYES, RINSE IMMED
W/PLENTY OF WATER & S EEK MED ADVICE. WEAR SUITABLE (SUPDAT)
Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:MECHANICAL EXHAUST REQUIRED.
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY SHOWER AND EYE BATH. WEAR SUITABLE
PROTECTIVE CLOTHING.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
OTHER PRECAUTIONS: PROTECTIVE CLOTHING. MATERIALS TO AVOID: SHAKEN.
INDIUM-CATALYZED OXIDATION OF ACETONITRILE IS SUSPECTED CAUSE.
INDIUM REACTS VIGOROUSLY W/MERCURY (II) BROMIDE AT 350C. A MIXTURE
OF INDIUM AND SULFUR IGNITE UPON HEATING RESULTING IN
INCANDESCENCE.
HCC:N1
Spec Gravity:7.3
Appearance and Odor:SILVER WIRE.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, SULFUR, STRONG ACIDS.MIX OF ACETONITRILE,
DINITROGEN TETRAOXIDE & INDIUM EXPLO WHEN (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NATURE OF DECOMPOSITION PRODUCTS NOT
KNOWN.
Waste Disposal Methods:MATERIAL IN ELEMENTAL STATE SHOULD BE RECOVERED
FOR REUSE OR RECYCLING. DISPOSE OF IN ACCORDANCE WITH FEDERAL,
STATE, AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.