===================== Product Identification =====================
MSDS NAME:BA4590 MAGNESIUM CARBON BATTERY
NIIN:00F032080
MSDS Number: BSPTC
=== Responsible Party ===
Company:RAYOVAC CORP
Address:601 RAYOVAC DR
Box:4960
City:MADISON
State:WI
ZIP:53711-4960
Country:US
Info Phone Num:608-275-3340/275-4495/275-4992(FAX)
Emergency Phone Num:608-275-3340
CAGE:77542
=== Contractor Identification ===
Company:RAYOVAC CORP
Address:601 RAYOVAC DRIVE
Box:City:MADISON
State:WI
ZIP:53711
Country:US
Phone:608-275-4735/800-255-3924
CAGE:77542
============= Composition/Information on Ingredients =============
Name:MAGNESIUM-ALUMINUM ALLOY
Fraction by Wt: 10-15%
Name:BARIUM CHROMATE(VI)
CAS:10294-40-3
RTECS #:CQ8760000
Fraction by Wt: 0.5-1.5%
OSHA PEL:0.1 MG(CR)/M3
ACGIH TLV:0.05 MG(CR)/M3
Name:MAGNESIUM PERCHLORATE
CAS:10034-81-8
RTECS #:SC8925000
Fraction by Wt: 5-10%
Name:MANGANESE DIOXIDE
CAS:1313-13-9
RTECS #:OP0350000
Fraction by Wt: 25-35%
OSHA PEL:5 MG/CUM
ACGIH TLV:5 MG/CUM (MN)
Name:COLUMBIA CARBON, CARBON BLACK, LAMPBLACK, BLACK PEARLS
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: 5-10%
Other REC Limits:3.5 MG/CUM (NIOSH)
OSHA PEL:3.5 MG/CUM
ACGIH TLV:3.5 MG/CUM
Name:LITHIUM CHROMATE
CAS:14307-35-8
Fraction by Wt: <0.01%
===================== Hazards Identification =====================
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:NONE
======================= First Aid Measures =======================
Eyes: FLUSH W/WATER. SKIN: WASH W/SOAP & WATER. OBTAIN
MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:FOAM, DRY POWDER; WATER MAY CAUSE ELECTRICAL SHORTS
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS TO
AVOID INHALATION OF HAZARDOUS.
Unusual Fire/Explosion Hazard:LIKE ANY SEALED CONTAINER, BATTERY CELLS
MAY RUPTURE WHEN EXPOSED TO EXCESSIVE HEAT, THIS COULD RESULT IN
THE RELEASE OF CORROSIVE MATL. SEE SUPP.
================== Accidental Release Measures ==================
Spill Release Procedures:COLLECT ALL RELEASED MATERIAL IN A PAIL FOR
WASTE DISPOSAL.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A DRY PLACE. DO NOT RECHARGE.
Other Precautions:DO NOT PACK, STORE, OR SHIP USED BATTERIES IN TIGHTLY
SEALED CONTAINERS. THE SLOW EVOLUTION OF HYDROGEN GAS FROM USED
BATTERIES MAY PRODUCE CONTAINER OVER-PRESSURE OR EXPLOSIVE
CONDITIONS.
============= Exposure Controls/Personal Protection =============
Supplemental Safety and Health
CON'T ON FIRE HAZARD: BATTERY CONTAINS A MAGNESIUM ALLOY WHICH MAY
IGNITE WHEN EXPOSED TO EXTREME FIRE CONDITIONS.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:ELECTRICAL SHORTING, HEAT
Hazardous Decomposition Products:MOLTEN & BURNING MAGNESIUM, MAGNESIUM
OXIDE FUMES, ASPHALT FUMES, HYDROGEN GAS
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|