Spill Release Procedures:ALLOW GAS TO FLOW IN TO A MIXED SOLUTION OF
CAUSTIC SODA & SLAKED LIME.IF POSSIBLE,KEEP IN A HOOD UNTIL
CYLINDER IS EMPTIED
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STRIKE CYLINDERS.KEEP IN WELL
VENTILATED DRY DEFINITE STORAGE AREA. PROTECT FROM HEAT.USE VALVE
PROTECTION CAP UNTIL CYLINDER IS SECURED.
Other Precautions:AVOID DRAGGING CYLINDER EVEN FOR SHORT DISTANCES.WHEN
RETURNING CYLINDER CLOSE VALVE BEFORE SHIPMENT.DO NOT EXCEED 125 F.
Respiratory Protection:SELF CONTAINED BREATHING APPARATUS
Ventilation:L0CAL RECOMMENDED
Protective Gloves:YES
Eye Protection:YES
Supplemental Safety and Health
ITEM IS KIT WITH CYLINDER.MSDS INFO IS FROM MATHESON GAS PROD WHO MADE
GAS IN CYLINDER.
Waste Disposal Methods:ALLOW GAS TO FLOW INTO A MIXED SOLUTION OF
CAUSTIC SODA & SLAKED LIME.IF POSSIBLE,KEEP IN A HOOD UNTIL
CYLINDER IS EMPTIED
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.