LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:HARMFUL IF INHALED. MAY
AFFECT BRAIN/NERV SYS CAUSING DIZZ, HDCH/NAUS. RPTD OVEREXPS MAY
LEAD PROGRESSIVELY TO STAG GAIT, CONFUSN, UNCON/COMA. CAUSES NOSE &
THROAT IRRIT. SKIN/EYE CONT:CAU SES IRRIT WHICH CAN LEAD TO DERM
W/RPTDOVEREXPS. INGEST:MAY CAUSE GI IRRIT, NAUS, VOMIT & DIARR.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CHRONIC:REPORTS HAVE SHOWN RPTD &
PRLNG OCCUP OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG. OVEREXP
TO XYLOL IN LAB ANIMALS HAS SHOWN LIVER ABNORMS, KIDNEY, LUNG,
SPLEEN & EYE DMG AS WELL AS ANEMIA. EFTS IN HUMANS HAS SHOWN LIVER
& CARDIAC ABNORMS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE FROM EXPOS, RESTORE BRTHG & NOTIFY MD.
EYES:FLUSH IMMED W/LG AMTS OF WATER FOR AT LST 15 MINS. NOTIFY MD.
SKIN:WASH AFFECTED AREA W/SOAP & WATER, REMOVE CONTAM CLTHG & WASH
BEFORE REUSE. INGEST:DO NOT INDUCE VOMIT. KEEP PERSONWARM, QUIET &
GET MED ATTN. ASPIRATION OF THIS MATL INTO THE LUNGS CAN CAUSE
CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.
===================== Fire Fighting Measures =====================
Flash Point:81.0F,27.2C
Lower Limits:SEE ING
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
CHEMICAL OR FOAM).
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. WATER MAY BE USED TO COOL CLSD CNTNRS TO
PVNT PRESS BUILD-UP & POSS AUTO-(SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. DO NOT APPLY TO HOT SURFACES.
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE AREA
& REMOVE W/INERT ABSORBENT & NONSPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE >120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA
CLASS I FLAMMABLE LIQUIDS.
Other Precautions:CONTAINERS SHOULD BE GROUNDED WHEN POURING. EMPTY
CONTAINER MAY BE HAZARDOUS.
Respiratory Protection:USE NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE
RESPIRATOR (TC23C) TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY
& ORGANIC VAPS DURING SPRAY APPLICATION. IN CONFINED AREAS:USE
NIOSH/MSHA APPRVD SUPPLIED- AIR RESPS/HOODS (TC19C).
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP TLV OF HAZ INGS BELOW ACCEPT LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORK GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:IGNITION OR EXPLOSION. IF WATER IS USED, FOG NOZZLES
ARE PREFERRED.
Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE & FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.