LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:POISON & CORROSIVE TO SKIN, EYES,
MUCOUS MEMBRANES OR LUNGS. MAY BURN ANY TISSUE & CAUSE BLINDNESS,
GI TRACT PERFORATION, COUGH, PULMONARY EDEMA. MAY CAUSE
METHEMOGLOBINEMIA. (INGESTION OF MASSIVE QUA NTITIES (>500CC) IS
UNLIKELY, BUT COULDCAUSE ELECTROLYTED DISTURBANCES).
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:EYE/SKIN: BURNING, IRRITATION, REDNESS, INHAL:
COUGH, SHORTNESS OF BREATH, PAIN. INGEST: PAIN, VOMITING, DIARRHEA,
SALIVATION, CYANOSIS. (SYMPTOMS UNLIKELY UNLESS MULTIPLE VIALS
INGESTED)
Medical Cond Aggravated by Exposure:NONE (WITH MASSIVE INGESTION
ELECTROLYTE DISTURBANCES MORE LIKELY IN PRESENCE OF KIDNEY
DISEASE).
======================= First Aid Measures =======================
First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: FLUSH
WITH WATER. INGEST: INDUCE VOMITING FOR LARGE INGESTIONS ONLY.
INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP).
===================== Fire Fighting Measures =====================
Flash Point:NOT IGNITABLE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:NONE.
Respiratory Protection:NIOSH/MSHA APPRVD ACID GAS TYPE DUST/MIST
RESPIRATOR REQUIRED IF MIST PRODUCTION OCCURS.
Ventilation:LOCAL/MECH EXHAUST: USE IN HOOD. SPECIAL: VENTILATE SPILLS.
Protective Gloves:ACID-PROOF GLOVES.
Eye Protection:ANSI APPRVD CHEM WORK GOGGS & (SUPDAT)
Other Protective Equipment:ACID PROOF APRON, LAB COAT, CLOSED SHOES.
EMERGENCY EYE WASH AND DELUGE SHOWER WHICH MEET ANSI DESIGN
CRITERIA .
Work Hygienic Practices:AVOID MIST OR AEROSOL FORMATION, DO NOT INHALE
OR HEAT DRIED RESIDUE.
Supplemental Safety and Health
EYE PROT: FULL LENGTH FACESHIELD.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:MAY GENERATE HYDROGEN ON EXPOSURE TO
METALS.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods:DISPOSE OF AS NON-HAZARDOUS WASTE. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE & FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.