MSDS  : ELECTRON AEROSOL ENVIRONMENTALLY PREFERRED DIELECTRIC SOLVNT
CAS  : 64475-85-0
NAME  : mineral spirits
===================== Product Identification =====================

MSDS NAME:ELECTRON AEROSOL ENVIRONMENTALLY PREFERRED DIELECTRIC SOLVNT
NIIN:01-371-8048
MSDS Number: BWZNW
=== Responsible Party ===
Company:SENTRY CHEMICAL CO INC
Address:1481 ROCK MOUNTAIN BLVD
Box:748
City:STONE MOUNTAIN
State:GA
ZIP:30086
Country:US
Info Phone Num:404-934-4242/FAX -0932/800-877-3339
Emergency Phone Num:404-934-4242
CAGE:8S927
=== Contractor Identification ===
Company:SENTRY CHEMICAL CO INC
Address:1481 ROCK MOUNTAIN BLVD
Box:748
City:STONE MOUNTAIN
State:GA
ZIP:30086
Country:US
Phone:770-934-4242
CAGE:8S927

============= Composition/Information on Ingredients =============

Name:MINERAL SPIRITS
CAS:64475-85-0
RTECS #:PY8240000
Fraction by Wt: >60%
Other REC Limits:NONE RECOMMENDED

===================== Hazards Identification =====================

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:CAN CAUSE GASTROINTESTINAL
IRRITATIO. INHALE:ASPIRATION INTO LUNGS MAY CAUSE INJURY.
EYES:EXPOSURE TO HIGH CONCENTRATIONS OF VAPORS MAY CAUSE SLIGHT
IRRITATION. SKIN:PROLONGED OR REPEATED EXPOS URE MAY CAUSE SKIN
IRRITATION.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:INGESTION-CAN CAUSE NAUSEA, VOMITING.
INHALATION-EXCESSIVE INHALATION OF VAPORS MAY CAUSE DIZZINESS OR
HEADACHE. SKIN-REPEATED LONGTERM CONTACT MAY CAUSE EXCESSIVE DRYING
OR FLAKING OF SKIN.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

======================= First Aid Measures =======================

First Aid:INGEST:DO NOT INDUCE VOMITING. PRODUCT CONTAINS HYDROCARBON,
CALL PHYSICIAN. INHALE:REMOVE TO FRESH AIR. IF BREATHING IS
DIFFICULT, GIVE OXYGEN, CALL PHYSICIAN. EYES:IRRIGATE IMMEDIATELY
WITH WATER FO R AT LEAST 15 MINUTES, CALL PHYSICIAN. SKIN:WASH OFF
IN FLOWING WATER OR SHOWER USING SOAP & WATER. REMOVE CONTAMINATED
CLOTHING & WASH BEFORE REUSE.

===================== Fire Fighting Measures =====================

Flash Point Method:TCC
Flash Point:FLAMMABLE AEROSL
Lower Limits:0.7%
Upper Limits:6%
Extinguishing Media:REGULAR FOAM, CO2 OR DRY CHEMICALS.
Fire Fighting Procedures:FIGHT AS A HYDROCARBON FIRE. WEAR
SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:AEROSOL CAN WILL BURST IF EXPOSED TO HEAT
OF FIRE.

================== Accidental Release Measures ==================

Spill Release Procedures:SMALL SPILL:REMOVE ALL SOURCES OF IGNIT!
ABSORB LIQUID ON ABSORB MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:STORE AS LEVEL 3 AEROSOL (NFPA 30B).
STORE AWAY FROM IGNITION SOURCES & AVOID BREATHING VAPORS. USE
W/ADEQUATE VENTILATION.
Other Precautions:ELECTRON DIELECTRIC SOLVENT IS COMBUSTIBLE
(FLASHPOINT <200F) & MUST BE HANDLED W/CARE AROUND OPEN FLAME OR
HEATED SURFACES. DO NOT USE AROUND HOT WORK!

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NOT REQUIRED UNDER CONDITIONS OF NORMAL USE. IF
VAPOR MIST IS GENERATED, USE A NIOSH/MSHA APPROVED ORGANIC VAPOR
RESPIRATOR W/DUST & MIST FILTER.
Ventilation:LOCAL EXHAUST:HOOD OR FAN. MECHANICAL:NONE REQUIRED.
Protective Gloves:RUBBER GLOVES ARE RECOMMENDED.
Eye Protection:SAFETY GLASSES ARE RECOMMENDED.
Other Protective Equipment:NONE REQUIRED.
Work Hygienic Practices:WASH HANDS AFTER USE.
Supplemental Safety and Health
NONE

================== Physical/Chemical Properties ==================

HCC:V3
Boiling Pt:B.P. Text:320F,160C
Vapor Pres:<3
Vapor Density:5
Spec Gravity:0.784 (H2O=1)
Evaporation Rate & Reference:0.15 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID W/MILD CITRUS ODOR.

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:OXIDES OF CARBON MAY BE FORMED UPON
COMBUSTION.

==================== Disposal Considerations ====================

Waste Disposal Methods:TREAT AS SIMPLE OIL WASTE. INCINERATE OR
LANDFILL IN MANNER CONFORMING TO STATE, FEDERAL & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
NITROGEN 7727-37-9
NICKEL-CADMIUM CYLINDRICAL CELLS 12054-48-7
7440-02-0
7440-43-9
1310-58-3
9002-86-2
LIQUID-PLUMR 1310-73-2
7681-52-9
LITHIUM/SULFUR DIOXIDE BATTERY 7439-93-2
7446-09-5
75-05-8
121 1804 VNF-1/RVNP LIQUID FIXER & REPLENISHER, CONCENTRATE 7783-18-8
7732-18-5
10196-04-0
10192-30-0
631-61-8
121 1804 VNF-1/RVNP LIQUID FIXER & REPLENISHER, WORK SOLN 7783-18-8
7732-18-5
10196-04-0
10192-30-0
631-61-8
CEE-BEE SILICONE REMOVER C-105HF 75-09-2
8030-30-6
108-88-3
27176-87-0
NITROGEN 7727-37-9
NITROGEN 7727-37-9
CLEAN CROP CARBARYL 4 L INSECTICIDE 63-25-2
BENOX A-40P 94-36-0
7732-18-5
1425B16 PR1425 B-2 ACCELERATOR 14307-33-6
127-19-5
112945-52-5
7732-18-5
1335-30-4
8031-18-3
NDC00205-5325-26 METHOTREXATE SODIUM INJECTION 59-05-2
NDC00205-5327-30 METHOTREXATE SODIUM INJECTION 59-05-2
ETHYL ACETATE,E-145-1 141-78-6
NITROGEN 7727-37-9
180 2107 VNF-1/RVNP PERSULFATE ACCELERATOR & REPL,PART B 7732-18-5
7631-90-5
64-19-7
127-09-3
60-00-4
180 2107,VNF-1/RVNP PERSULFATE ACCEL. & REPL, WORK SOL'N 7732-18-5
7631-90-5
127-09-3
16111-27-6
64-19-7
KODAK RP X-OMAT DEVELOPER REPLENISHER, PART A 7732-18-5
10117-38-1
123-31-9
497-19-8
1310-58-3
7757-83-7
111-46-6
KODAK RP X-OMAT DEVELOPER REPLENISHER, PART B 64-19-7
92-43-3
7732-18-5
127-08-2
7420-89-5
1310-58-3
124 9259 RP X-OMAT DVLPR REPLENISHER,TO MAKE 10 GAL,PART C 7732-18-5
111-30-8
64-19-7
5401-94-5
KODAK RP X-OMAT DEVELOPER REPLENISHER, WORKING SOLUTION 7732-18-5
10117-38-1
7420-89-5
123-31-9
127-08-2
1310-58-3
D-5 CLEANER/DEGREASER CONCENTRATE 7320-34-5
10101-89-0
1330-72-7
112-07-2
68131-39-5
2272-11-9
ISOPROPANOL ANHYDROUS 67-63-0
2020/2300/2350 MAGNETIC DRY IMAGER P/N 6R13 39382-25-7
1309-37-1
1333-86-4
112945-52-5
557-05-1
NITROGEN 7727-37-9
NITROGEN 7727-37-9
GUARDIAN WETTING AGENT 127087-87-0
7732-18-5
AMPICILLIN SODIUM/SULBACTAM SODIUM IV/IM,UNASYN 69-52-3
69388-84-7
PERFECT SEAL NO. 4 8001-79-4
68152-81-8
7631-86-9
67-63-0
107-98-2
1344-95-2
65996-61-4
LS6 BA LITHIUM THIONYL CHLORIDE BATTERY 7439-93-2
7719-09-7
NICKEL-CADMIUM BATTERY PACKS,48-11-0100 12054-48-7
7440-43-9
21041-95-2
1310-73-2
1310-58-3
1310-65-2
ENVIROSOLV CRX 112-34-5
141-43-5
196 3768 HOBBY-PAC COLOR SLIDE KIT FIRST DEVELOP,WORK SOLN 7732-18-5
10117-38-1
21799-87-1
584-08-7
497-19-8
196 3768 HOBBY-PAC COLOR SLIDE KIT STABILIZER,WORKING SOLN 7732-18-5
50-00-0
67-56-1
24938-91-8
CANON STARTER FOR CLC 200/300 BLACK 39382-25-7
72869-85-3
834 1950, KODAK EKTACOLOR RA BLEACH FIX & REPLENISHER,PART A 7732-18-5
7783-18-8
7631-90-5
10192-30-0
10196-04-0
142 8366, EKTACOLOR RA BLEACH FIX & REPLENISHER, PART B 7732-18-5
21265-50-9
20824-56-0
156 9201, EKTACOLOR RA BLEACH FIX & REPLENISHER, PART C 64-19-7
FORANE 134A 811-97-2
ELECTRON AEROSOL ENVIRONMENTALLY PREFERRED DIELECTRIC SOLVNT 64475-85-0
STADOL NASAL SPRAY (10 MG/ML) 58786-99-5
7732-18-5
121-54-0
77-92-9
7647-14-5
1310-73-2
SYNTHETIC CLEANER,2-182 7758-19-4
120-40-1
9016-45-9
27176-87-0
61790-12-3
111-42-2
AER-O-LITE-3% 7732-18-5
112-34-5
107-21-1
142-87-0
834 1950 EKTACOLOR RA BLEACH FIX AND REPELENISHER NR, W.S. 7732-18-5
7783-18-8
21265-50-9
64-19-7
7631-90-5
817 7222 MICROFILM FIXER AND REPLENISHER,CONCENTRATE 7732-18-5
7783-18-8
127-09-3
64-19-7
7681-57-4
7631-90-5
64-19-7
817 7222 MICROFILM FIXER AND REPLENISHER,WORKING SOLUTION 7732-18-5
7783-18-8
127-09-3
64-19-7
7681-57-4
7631-90-5
MOSQUITO DUNKS
ENVIROSOLVE 655 64475-85-0
124-38-9
KUSHON SPONGE

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net