236C0910, BAR RUST 236 MULTI PURPOSE COATING (SUPDAT)
CAS  
:
64742-95-6 110-43-0
NAME  
:
spill proc: and non-sparking tools. store in closed other precs: the mixture of base & converter portions will resp prot: when used in restricted vent areas, wear ing 9: msha apprvd resp when flame cutting, welding, vent: hlth stds in mixing, application & curing areas & to ing 11: during welding & flame cutting on surfs coated ing 12: removing heavy solv vaps from lower levels of work amine compound ld50: (oral, rat) 5 g/kg solvent naphtha (petroleum), light aromatic; (high flash 2-heptanone; (methyl n-amyl ketone) vp: 2.14. ld50: volatile organic compound: 147.37 g/l supdat: may cause health hazard. symptoms may not be immed first aid proc: consult md immed. do not induce vomit.
LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: IRRIT OF RESP TRACT;
HDCH, NAUS, DIZZ, WEAK & FATIGUE. EXTREME EXPOS CAN RESULT IN UNCON
& EVEN RESP ARREST. SKIN/EYES: CAN CAUSE STOMACH &/OR INTESTINAL
IRRIT, NAUS, VOMIT & DIARR. CHRO NIC: REPORTS HAVE ASSOC RPTD &
PRLNG OCCUP OVEREXP TO SOLVENTS W/PERM BRAIN & NERVOUS SYSTEM
DAMAGE. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: PRLNG/RPTD BREATHING OF SPRAY MIST
&/OR SANDING DUST OVER A PERIOD OF YEARS MAY CAUSE DUST DISEASE OF
THE LUNGS. NOTICE: INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING
& INHALING THE CONTE NTS MAY BE HARMFUL OR FATAL.
Medical Cond Aggravated by Exposure:NONE, WHEN USED IN ACCORDANCE WITH
SAFE HANDLING AND USE INFORMATION.
======================= First Aid Measures =======================
First Aid:INHAL: IF DFCLT BRTHG EXPERIENCED, LEAVE AREA TO OBTAIN FRESH
AIR. IF CONTINUED DFCLTY EXPERIENCED, SUMMON MED ASSISTANCE IMMED.
IF BRTHG CEASES, RESTORE USING APPRVD CPR TECHNIQUE SUMMON MED HELP
IMM ED. EYES: FLUSH IMMED W/LG AMTS OF WATER FOR AT LEAST 15 MIN.
GET MED ASSISTANCE. SKIN: WASH AFFECTED AREAS W/SOAP & WATER.
REMOVE SOILED CLTHG. GET MED ASSISTANCE IF IRRIT PERSISTS. INGEST:
(ING 6)
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:100F,38C
Lower Limits:1%
Extinguishing Media:IN CASE OF FIRE USE CO*2 DRY CHEMICAL, FOAM OR
OTHER NFPA APPROVED METHOD FOR TREATING A CLASS B FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
SUMMON PROFESSIONAL FIREFIGHTERS. WATER SPRAY MAY BE INEFTIVE. IF
WATER IS USED, FOG NOZZ PREF. IF (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & FLAME. DUE TO PRESS BUILD-UP, CLSD CNTNRS
EXPOS TO EXTREME HEAT MAY EXPLODE. NEVER USE (SUPDAT)
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAMES, HOT
SURFS & ELEC, STATIC OR FRICTIONAL SPKS). PVNT BRTHG OF VAP. VENT
AREA. BEFORE ATTEMPTING CLEAN-UP, REFER TO HAZ CAUTION INFO IN
OTHER SECTIONS OF MSDS. CON TAIN SPILLED MATL & REMOVE W/INERT
ABSORB (ING 7)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPK & FLAMES.
PVNT BUILD-UP OF VAPS BY MAINTAINING CONTINUOUS FLOW OF FRESH AIR.
DO NOT STORE > 120F, NEAR FIRE OR OPEN FLAME.
Other Precautions:DO NOT SMOKE. STORE LG QTYS IN BLDGS TO COMPLY W/OSHA
1910.106. KEEP CNTNR CLSD WHEN NOT IN USE. DO NOT TRANSFER CONTENTS
TO BOTTLES/OTHER UNLABELLED CNTNRS. DO NOT REUSE EMPTY CNTNRS. IF
MATL IF PART OF TWO COMPONENT PROD, THEN (ING 8)
Respiratory Protection:DO NOT BREATHE VAPS, SPRAY MIST/SANDING DUST.
WHEN SPRAY APPLIED IN OUTDOOR/OPEN AREAS & DURING SANDING/GRINDING
OPERATIONS, USE NIOSH/MSHA APPRVD MECH FILTER RESP TO REMOVE SOLID
AIRBORNE PATRICLES O F OVERESPRAY & SANDING DUSTS. (ING 9)
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP AIR CONTAMINANT CONC BELOW CURRENT APPLIC SFTY & (ING 11)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:DO NOT GET ON SKIN. SOLVENT IMPERMEABLE
CLOTHING & BOOTS TO PREVENT SKIN CONTACT ARE RECOMMENDED.
Work Hygienic Practices:REMOVE & WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: CLEAR CONVERTER. FIRE FIGHT PROC: EXPOS TO
FIRE/EXTREME HEAT, WATER SHOULD BE USED TO COOL CLSD CNTNRS & PVNT
PRESS BUILD UP OR POSS AUTOIGNIT. FIRE/EXPLO HAZ: WELDING/CUTTIN G
TORCH ON/NEAR CNTNR (EVEN EMPTY) AS PROD/ITS RESIDUE MAY IGNITE.
DURING EMER CNDTNS OVEREXP TO DECOMP PRODS (ING 5)
Boiling Pt:B.P. Text:>300F,>149C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.9812
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:17.68
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOX FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CARBON MONOXIDE, CARBON DIOXIDE,
OXIDES OF NITROGEN.
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.