LD50 LC50 Mixture:ORAL LD50 (RAT): >34.6 G/KG (SEE SUPP)
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:OVEREXPOSURE TO VAPOR DURING HEAT
CURING MAY CAUSE IRRITATION/INJURY OF THE RESPIRATORY TRACT & EYE
IRRITATION. FIBERGLASS IS CONSIDERED A NUISANCE PARTICULATE.
ANTIMONY TRIOXIDE CAUSES MILD EYE IRRI TATION. BENZOYL PEROXIDE
CAUSES MILD EYE IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION
======================= First Aid Measures =======================
First Aid:SKIN: WASH W/SOAP & WATER. EYES: IMMEDIATELY IRRIGATE
W/PLENTY OF WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN ALL
CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER, CO2/DRY CHEMICAL
Fire Fighting Procedures:WEAR POSITIVE PRESSURE SCBA.
Unusual Fire/Explosion Hazard:AUTOIGNITION TEMP: >500F.
Spill Release Procedures:SWEEP UP & PLACE IN A WASTE DISPOSAL
CONTAINER. FLUSH AREA W/WATER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID SKIN CONTACT.
Other Precautions:FOOD BEVERAGES & TOBACCO PRODUCTS SHOULDN'T BE
CARRIED/STORED/CONSUMED WHERE PRODUCT IS USED.
Respiratory Protection:WHERE EXPOSURES ARE < THE PERMISSIBLE EXPOSURE
LIMIT, NO RESPIRATORY PROTECTION IS REQUIRED. WHEN EXCEEDED, USE
RESPIRATOR APPROVED BY NIOSH. USE A RESPIRATOR WHEN CUTTING,
GRINDING/SANDING OF PARTS F ABRICATED AFTER CURING OF MATERIAL.
Ventilation:WHEN NOT USED IN A CLOSED SYSTEM, GOOD ENCLOSURE & LOCAL
EXHAUST SHOULD BE PROVIDED WHEN SPRAYING/CURING AT HIGH TEMPS.
Protective Gloves:IMPERVIOUS
Eye Protection:CHEMICAL SPLASH PROOF GOGGLES
Other Protective Equipment:FACESHIELD, APRON, WORKPANTS, LONG SLEEVE
WORK SHIRT, DISPOSABLE COVERALLS, BARRIER CREAMS, EYEWASH, SAFETY
SHOWER.
Work Hygienic Practices:BEFORE EATING, DRINKING/SMOKING, WASH FACE &
HANDS W/SOAP & WATER.
Supplemental Safety and Health
ORAL LD50 INFORMATION IS FOR ANTIMONY TRIOXIDE. CYANAMID WAS BOUGHT BY
CYTEC AT 201-652-6013.
Decomp Temp:Decomp Text:>500F
Vapor Pres:NEGLIGIBLE
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR TACKY FILM W/SWEET DIALLYLPHATHALATE ODOR
Percent Volatiles by Volume:5
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AMINES
Stability Condition to Avoid:TEMP > 80F
Hazardous Decomposition Products:CO, CO2, PHOSGENE, CHLORINE GAS,
HYDROGEN CHLORIDE GAS
Conditions to Avoid Polymerization:AMINES, TEMP > 80F
Waste Disposal Methods:DISPOSE OF IAW/LOCAL, STATE & FEDERAL
REGULATIONS. NA9188
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.