Effects of Overexposure:IRRITATION OF EYES,NOSE AND THROAT.
HEADACHE,INTOXICATION & DROWSINESS MAY OCCUR.
======================= First Aid Measures =======================
First Aid:IN CASE OF CONTACT,FLUSH THROUGHLY WITH WATER.FOR
INHALATION,REMOVE TO FRESH AIR AND ADMINISTER OXYGEN.
===================== Fire Fighting Measures =====================
Flash Point:50F TCC
Lower Limits:4.3
Upper Limits:19.0
Extinguishing Media:CO2 OR DRY CHEMICAL EXTINGUISHER
Fire Fighting Procedures:WATER IN STRAIGHT HOSE STREAM WILL SCATTER AND
SPREAD FIRE,
Unusual Fire/Explosion Hazard:KEEP AWAY FROM HEAT,SPARKS AND OPEN
FLAME,KEEP CONTAINER CLOSED WHEN NOT IN USE.USE IN VENTILATED AI
Spill Release Procedures:REMOVE ALL SOURCE OF IGNITION. AVOID BREATHING
OF VAPORS OR CONTACT WITH EYES. CONTAIN SPILL IN A DIKED AREA TO
MINIMIZE VAPORS.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 100F. IF NECESSARY
TO TRANSFER CONTENTS TO ANOTHER CONTAINER,GLASS,PLASTIC,SPECIAL
LINED STEEL OR TIN ARE ACCEPTABLE.
Other Precautions:OTHER HANDLING IN ACCORDANCE WITH NFPA BULLETIN 30
AND 77
Respiratory Protection:WHERE HIGH CONCENTRATIONS OF VAPOR EXIST,USE ALL
PURPOSE CANISTER
Ventilation:LOCAL EXHAUST-FROM FLOOR AND LOW AREAS
Eye Protection:SAFETY GOGGLES
Supplemental Safety and Health
ALL ELECTRICAL EQUIPMENT MUST BE EXPLOSION-PROOF
Waste Disposal Methods:IF CUSTOM DISPOSAL SERVICE IS NOT AVAILABLE,
LARGE QUANTITIES MAY BE BURNED IN A COMBUSTION CHAMBER BY A
COMPETENT ENGINEER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.