| MSDS   | : | ISOVUE 250 (IOPAMIDOL INJECTION 51 W/V%) | | CAS   | : | 7732-18-5 77-86-1 62-33-9 7647-01-0 60166-93-0 | | NAME   | : | water 1,3-propanediol , 2-amino-2-(hydroxymethyl), tromethamine calcium disodium edta, edetate calcium disodium hydrochloric acid, hydrogen chloride, muriatic acid 1,3-benzenedicarboxamide, iopamidol
|
| |
|
|
===================== Product Identification =====================
MSDS NAME:ISOVUE 250 (IOPAMIDOL INJECTION 51 W/V%)
NIIN:00F047347
MSDS Number: BZCSH
=== Responsible Party ===
Company:E R SQUIBB MEDATOPE DIV
Address:5 GORDIS RD BLDG 124
Box:191
City:NEW BRUNSWICK
State:NJ
ZIP:08903-5000
Country:US
Info Phone Num:800-332-2056/908-519-3843
Emergency Phone Num:908-519-3843/609-921-4081
Preparer's Name:DR E HAYES
CAGE:GO533
=== Contractor Identification ===
Company:E R SQUIBB MEDATOPE DIV
Address:5 GORDIS RD BLDG 124
Box:191
City:NEW BRUNSWICK
State:NJ
ZIP:08903
Country:US
Phone:609-921-4081
CAGE:4T649
Company:E R SQUIBB MEDATOPE DIV
Address:5 GORDIS RD BLDG 124
Box:191
City:NEW BRUNSWICK
State:NJ
ZIP:08903-5000
Country:US
Phone:800-332-2056/908-519-3843
CAGE:GO533
============= Composition/Information on Ingredients =============
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: >1%
Name:1,3-PROPANEDIOL , 2-AMINO-2-(HYDROXYMETHYL), TROMETHAMINE
CAS:77-86-1
RTECS #:TY2900000
Fraction by Wt: <1%
Name:CALCIUM DISODIUM EDTA, EDETATE CALCIUM DISODIUM
CAS:62-33-9
RTECS #:EV7700000
Fraction by Wt: <1%
Name:HYDROCHLORIC ACID, HYDROGEN CHLORIDE, MURIATIC ACID
HYDROCHLORIDE
CAS:7647-01-0
RTECS #:MW4025000
Fraction by Wt: <1%
Other REC Limits:7 PPM
OSHA PEL:5 PPM
ACGIH TLV:C 11 MG/CUM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:1,3-BENZENEDICARBOXAMIDE, IOPAMIDOL
CAS:60166-93-0
RTECS #:CZ2235000
Fraction by Wt: 51%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ISOVUE SOLUTIONS ARE INTENDED FOR
INTRAVENOUS ADMINISTRATION. ADVERSE REACTIONS HAVE BEEN REPORTED
FOLLOWING INTRAVENOUS ADMINISTRATION & HAS PRODUCED
HYPERSENSITIVITY REACTIONS WHICH RARELY HAVE BEEN SEVERE/FATAL, IN
SUSCEPTIBLE INDIVIDUALS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:HEADACHES, NAUSEA, VOMITING, MUSCULOSKELETAL
PAIN & HYPOTENSION.
Medical Cond Aggravated by Exposure:SENSITIVITY TO IODINE.
======================= First Aid Measures =======================
Eyes: FLUSH W/LARGE AMOUNTS OF WATER FOR 15-20 MINS. SKIN:
WASH W/SOAP & WATER. INGESTION: VOMITING MAY BE INDUCED IF A PERSON
IS CONSCIOUS & IF INGESTED W/IN THE PAST 3 HOURS. NEVER INDUCE
VOMITING I F UNCONSCIOUS/CONVULSING. INHALATION: REMOVE TO FRESH
AIR. GIVE CPR/OXYGEN IF NEEDED. OBTAIN MEDICAL ATTENTION IN ALL
CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER.
Fire Fighting Procedures:EVACUATE AREA. WEAR SCBA & FULL PROTECTIVE
CLOTHING. USE WATER TO COOL CONTAINERS. FIGHT FROM A MAXIMUM
DISTANCE. DIVERTRUNOFF TO SAFE AREA.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR CHEMICAL SAFETY GOGGLES, A GOWN & LATEX
GLOVES. ABSORB ONTO ABSORBENT & PLACE INTO AN APPROPRIATE CONTAINER
FOR DISPOSAL. VENTILATE & DECONTAMINATE AFTER MATERIAL HAS BEEN
PICKED UP.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AT ROOM TEMPERATURE NOT
EXCEEDING 86F. PROTECT FROM LIGHT.
Other Precautions:DIAGNOSTIC AGENTS ARE INTENDED FOR USE UNDER THE
DIRECTION OF A PHYSICIAN &/UNDER CONDITIONS OF USE DESCRIBED ON THE
LABEL. AVOID CONTACT W/SKIN & EYES. DON'T INGEST.
============= Exposure Controls/Personal Protection =============
Protective Gloves:LATEX
Eye Protection:CHEMICAL SAFETY GOGGLES
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. REMOVE/LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
THIS MATERIAL SAFETY DATA SHEET IS INTENDED FOR USE BY PERSONNEL WHO
HANDLE THESE MATERIALS AS PART OF THEIR JOB RESPONSIBILITIES. IT
DOESN'T ADDRESS THE DIAGNOSTIC USE OF THESE MATERIALS.
================== Physical/Chemical Properties ==================
pH:6.5-8
Solubility in Water:MISCIBLE
Appearance and Odor:AQUEOUS SOLUTION W/NO REMARKABLE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:LIGHT
Hazardous Decomposition Products:THERMAL/BURNING: CO, CO2, HYDROGEN
CHLORIDE, HYDROGEN IODIDE, IODINE, NITROGEN OXIDES.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|