===================== Product Identification =====================
MSDS NAME:2-(2-ETHOXYETHOXY)ETHANOL, O-173
NIIN:00N066233
MSDS Number: CBDKV
=== Responsible Party ===
Company:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Info Phone Num:215-692-3026
Emergency Phone Num:215-692-3026
CAGE:84898
=== Contractor Identification ===
Company:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Phone:215-692-3026
CAGE:84898
Company:CHEM SERVICE, INC
Address:660 TOWER LN
Box:599
City:WEST CHESTER
State:PA
ZIP:19301-9650
Country:US
Phone:610-692-3026
CAGE:8Y898
============= Composition/Information on Ingredients =============
Name:ETHANOL, 2-(2-ETHOXYETHOXY)-; (DIETHYLENE GLYCOL MONOETHYL
ETHER)
CAS:111-90-0
RTECS #:KK8750000
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(RAT) 6500 MG/KG.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALL CHEMICALS SHOULD BE CONSIDERED
HAZARDOUS - AVOID DIRECT PHYSICAL CONTACT! LACHRYMATOR-CAUSES
SEVERE EYE IRRITATION. CAN CAUSE SKIN IRRITATION. THIS COMPOUND IS
GENERALLY CONSIDERED TO BE NON-TOXIC .
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes:FLUSH CONTINUOUSLY W/WATER FOR AT LST 15-20 MINS.
SKIN:FLUSH W/WATER FOR 15-20 MINS. IF NO BURNS HAVE OCCURRED-USE
SOAP & WATER TO CLEANSE SKIN. INHAL:REMOVE PATIENT TO FRESH AIR.
ADMIN OXYG IF P ATIENT IS HAVING DFCLTY BRTHG. IF PATIENT HAS
STOPPED BRTHG ADMIN ARTF RESP. IF PATIENT IS IN CARDIAC ARREST
ADMIN CPR. CONTINUE LIFE SUPPORTING MEASURES UNTIL MED ASSISTANCE
HAS ARRIVED. (SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point:205F,96C
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:THIS IS A COMBUSTIBLE COMPOUND. PEROXIDE
FORMER-DISCARD OUT OF DATE MATERIAL. USE EXTREME CARE IN HANDLING.
NO EXPLOSION LIMITS ARE AVAILABLE FOR THIS COMPOUND.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA-REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR
MATERIAL. SWEEP UP & PLACE IN AN APPROPRIATE CONTAINER. HOLD FOR
DISPOSAL. WASH CONTAMINATED SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT W/SKIN, EYES & CLOTHING.
KEEP TIGHTLY CLOSED & STORE IN A COOL, DRY PLACE. STORE ONLY
W/COMPATIBLE CHEMICALS.
Other Precautions:PERSONS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD
NOT HANDLE THIS CHEM/ITS CNTNR. THIS PROD IS FURNISHED FOR LAB USE
ONLY! PRODS MAY NOT BE USED AS DRUGS, COSMETICS,
AGRICULTURAL/PESTICIDAL PRODS, FO OD ADDITIVES/AS HOUSEHOLD CHEMS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . USE APPROPRIATE OSHA/MSHA SAFETY EQUIPMENT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN IN THE
LABORATORY.
Supplemental Safety and Health
FIRST AID PROC:NOTE:ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF
POIS. IT SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. MED ADVICE
CAN BE OBTAINED FROM POIS CTL CTR. EYE PROT:& FULL LENGTH FACE
SHIELD .
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:385F,196C
Spec Gravity:0.985
Appearance and Odor:COLORLESS LIQUID.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
REACTS W/ACID HALIDES & ANHYDRIDES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER
& SCRUBBER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD ***