===================== Product Identification =====================
MSDS NAME:PLASTIC LOOSEFILL RESIN
NIIN:00N075268
MSDS Number: CCTSP
=== Responsible Party ===
Company:FOAM PAC MATERIALS CO
Address:4758 DEVITT DR
City:CINCINNATI
State:OH
ZIP:45246
Country:US
Info Phone Num:800-424-9300(CHEMTREC)
Emergency Phone Num:800-424-9300(CHEMTREC)
Preparer's Name:STEVE WEST
CAGE:FXAMP
=== Contractor Identification ===
Company:FOAM PAC MATERIALS CO
Address:4758 DEVITT DR
Box:City:CINCINNATI
State:OH
ZIP:45246
Country:US
Phone:800-424-9300(CHEMTREC)
CAGE:FXAMP
============= Composition/Information on Ingredients =============
Name:STYRENE POLYMER; (POLYSTYRENE)
CAS:9003-53-6
RTECS #:WL6475000
Fraction by Wt: >92-94%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:BUTANE, 2-METHYL-; (1-PENTANE) % WT: >5.5-6.5
CAS:78-78-4
RTECS #:EK4430000
Fraction by Wt: <6.5%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:COLORANT; (COLOR CONCENTRATE)
Fraction by Wt: <0.5%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPDAT: TO PENTANE MAY CAUSE LOW BLOOD OXYGEN LEVELS & EYE
IRRIT. PENTANE WAS PART OF A MIXTURE WHICH CAUSED (ING 5)
RTECS #:9999999ZZ
Name:ING 4: POLYNEUROPATHY (NERVE DMG); HOWEVER, THERE IS NOT
CLEAR EVID THAT PENTANE CAUSES PERIPHERAL NERVOUS SYS (ING 6)
RTECS #:9999999ZZ
Name:ING 5: EFFECTS. RESULTS OF IN VITRO (TEST TUBE)
MUTAGENICITY TESTS W/PENTANE HAVE BEEN NEGATIVE.
RTECS #:9999999ZZ
Name:FIRST AID PROC: ABSOLUTELY NECESSARY. NO SPECIFIC ANTIDOTE.
SUPPORTIVE CARE. TREATMENT BASED ON JUDGMENT OF MD (ING 8)
RTECS #:9999999ZZ
Name:ING 7: IN RESPONSE TO REACTIONS OF PATIENT.
RTECS #:9999999ZZ
Name:OTHER PRECS: TO AVOID IGNIT OF THIS ATM, OBSERVE THE
FOLLOWING PRECS. (1)KEEP AWAY FROM OPEN FLAME, STATIC (ING 10)
RTECS #:9999999ZZ
Name:ING 9: SPARKS, LIGHTED CIGARETTES & OTHER SOURCES OF IGNIT
WHEN OPENING THE CNTNR. (2)OPEN CNTNR IN WELL-VENTD (ING 11)
RTECS #:9999999ZZ
Name:ING 10: AREA & ALLOW ENOUGH TIME TO PERMIT ESCAPE OF FLAM
VAPS BEFORE EMPTYING. THE FOAMABILITY OF EXPANDABLE (ING 12)
RTECS #:9999999ZZ
Name:ING 11: POLYSTYRENE IS REDUCED BY BLOWING AGENT LOSS.
THEREFORE, BARRIER FILM LINER SHOULD BE KEPT CLOSED & THE (ING 13)
RTECS #:9999999ZZ
Name:ING 12: UNEXPANDED MATL STORED BELOW 90F TO MINIMIZE SUCH
LOSS. IF ACCIDENTALLY IGNITED BY SMALL FLAME SOURCE, (ING 14)
RTECS #:9999999ZZ
Name:ING 13: IT IS COMBUST & SHOULD NOT BE EXPOSED TO OPEN FLAME
OR OTHER IGNIT SOURCE. SAFE HANDLING & STORAGE (ING 15)
RTECS #:9999999ZZ
Name:ING 14: PRACTICES, AS FOR ANY COMBUST MATL, SHOULD BE
OBSERVED.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: SOLID/DUST MAY CAUSE IRRIT OR
CORNEAL INJURY DUE TO MECH ACTION. SKIN: ESSNTLY NONIRRIT TO SKIN.
MECH INJURY ONLY. SKIN ABSORPTION IS UNLIKELY DUE TO PHYSICAL
PROPERTIES. INGEST: SINGLE DOSE ORAL TOX IS BELIEVED TO BE VERY
LOW. NO HAZS ANTIC. INHAL: DURING EXPANSION SM AMTS OF PENTANE ARE
RELSD. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: EXCESSIVE EXPOS TO PENTANE MAY CAUSE
IRRIT OF UPPER RESP TRACT. EXCESSIVE EXPOS TO PENTANE MAY CAUSE
CNS, ANESTHETIC OR NARCOTIC EFTS & MAY INCR SENSITIVITY TO
EPINEPHRINE & INCR MYOCARDIAL IRRITABILITY (IRREGULAR HEARTBEATS).
INCONFINED OR POORLY VENTDS AREAS, PENTANE VAPS CAN READILY ACCUM &
CAN (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST: CALL MD IMMEDIATELY . EYES: FLUSH EYES W/PLENTY OF
WATER FOR AT LEAST 15 MIN; MECHANICAL EFTS ONLY. SKIN: WASH OFF IN
FLOWING WATER OR SHOWER. INHAL: REMOVE TO FRESH AIR. IF NOT
BREATHIN G GIVE MOUTH-TO-MOUTH RESUSCITATION. IFBREATHING IS
DIFFICULT GIVE OXYGEN. CALL MD. NOTE TO MD: EXPOSURE MAY INCREASE
"MYOCARDIAL IRRITABILITY." DO NOT ADMINISTER SYMPATHOMIMETIC DRUGS
UNLESS (ING 7)
===================== Fire Fighting Measures =====================
Flash Point:510F,266C
Extinguishing Media:WATER FOG, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . APPLY LARGE VOLUME OF WATER DIRECTLY ON FLAME OR
BURNING SURFACE.
Unusual Fire/Explosion Hazard:EMITS DENSE BLACK SMOKE WHEN BURNED.
================== Accidental Release Measures ==================
Spill Release Procedures:SWEEP UP AND REUSE IF UNCONTAMINATED OR
DISPOSE OF AS GIVEN IN WASTE DISPOSAL METHOD.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DURING EXPANSION & CURING, CHECK FOR
BLOWING AGENT TLV LIMITS ON A REGULAR BASIS. MAINTAIN ADEQUATE
VENTILATION TO REMAIN BELOW TLV LIMITS.
Other Precautions:THIS MATL CONTAINS A FLAMMABLE BLOWING AGENT W/LOWER
FLAMMABLE LIMIT OF 1.5% IN AIR & UPPER FLAMMABLE LIMIT OF 7.8% IN
AIR. WHEN EXPANDABLE POLYSTYRENE IS STORED IN CLOSED CNTNRS, A
FLAMMABLE ATMOSHPE RE W/IN THE CNTNR CAN DEVELOP. (ING 9)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:ATMOSPHERIC LEVELS SHOULD BE MAINTAINED BELOW
THE EXPOSURE GUIDELINES. WHEN RESPIRATORY PROTECTION IS REQUIRED
FOR CERTAIN OPERATIONS, USE A NIOSH APPROVED AIR-PURIFYING
RESPIRATOR.
Ventilation:GOOD GENERAL VENT SHOULD BE SUFFICIENT FOR MOST CONDITIONS.
LOCAL EXHAUST VENT MAY BE NECESSARY FOR SOME OPERATIONS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . NO
PRECAUTION OTHER THAN CLEAN-BODY COVERING CLOTHING SHOULD BE
NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: CAUSE UNCON & DEATH DUE TO DISPLACEMENT OF OXYGEN
(SIMPLE ASPHYXIA). REPRESENTATIVE INDUS HYGIENE SURVEYS OF
OPERATIONS WHERE SUGGESTED HNDLG PRECS ARE FOLLOWED SHOW LEVELS TO
BE BELO W EXPOS GUIDELINES & LEVELS WHICH CAUSEACUTE EFTS. SYSTEMIC
(OTHER TARGET ORGAN) EFTS: RPTD EXCESSIVE EXPOS (ING 4)
================== Physical/Chemical Properties ==================
Solubility in Water:INSOLUBLE
Appearance and Odor:FOAMED POLYSTYRENE PIECES; VERY SLIGHT PENTANE GAS
ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
HYDROCARBONS.
Stability Condition to Avoid:TEMPS >100C (212F) WILL CAUSE EXPANSION &
RELEASE OF BLOWING AGENT. TEMPS >300C (572F) WILL RELEASE COMBUST
GASES.
Hazardous Decomposition Products:DOES NOT NORMALLY DECOMPOSE; WILL
BREAK INTO FRAGMENTS WITH EXTENDED EXPOSURE TO SUNLIGHT.
==================== Disposal Considerations ====================
Waste Disposal Methods:BURY IN APPROVED LANDFILL OR BURN IN ADEQUATE,
APPROVED INCINERATOR IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|