===================== Product Identification =====================
MSDS NAME:D34-950 DEEP CYCLE BATTERIES (GROUP 34), SEALED LEAD ACID
NIIN:01-457-5392
Status Code:A
MSDS Number: CKGQC
=== Responsible Party ===
Company:OPTIMA BATTERIES INC
Address:17500 E 22ND AVENUE
City:AURORA
State:CO
ZIP:80011
Country:US
Info Phone Num:303-448-8899/448-8899
Emergency Phone Num:(800)424-9300
Resp. Party Other MSDS Num.:OBI-0001D
Chemtrec Ind/Phone:(800)424-9300
CAGE:0UJ55
=== Contractor Identification ===
Company:OPTIMA BATTERIES INC
Address:17500 E 22ND AVENUE
Box:City:AURORA
State:CO
ZIP:80011
Country:US
Phone:303-448-8899 OR 800-292-4359
CAGE:0UJ55
============= Composition/Information on Ingredients =============
Name:LEAD COMPOUNDS
CAS:7439-92-1
RTECS #:OF7525000
Minumum % Wt:63.
Maxumum % Wt:81.
ACGIH TLV:0.15 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:SULFURIC ACID ELECTROLYTE
CAS:7664-93-9
RTECS #:WS5600000
Minumum % Wt:17.
Maxumum % Wt:25.
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3
ACGIH STEL:3 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:POLYPROPYLENE CASE MATERIAL
CAS:9003-07-0
RTECS #:UD1842000
Minumum % Wt:2.
Maxumum % Wt:6.
Name:SEPARATOR/PASTER PAPER FIBROUS GLASS
CAS:65997-17-3
Code:F
Minumum % Wt:1.
Maxumum % Wt:4.
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE STATED BY MANUFACTURER
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NONE EXPECTED FOR FINISHED PRODUCT
UNDER NORMAL CONDITIONS OF USE. IN ITS MANUFACTURED AND SUPPLIED
STATE, THE PRODUCT IS CONSIDERED NON-HAZARDOUS. KEEP AWAY FROM
FLAMES DURING AND IMMEDIATELY AFTER C HARGE. NO SIGNIFICANT HEALTH
EFFECTS ARE ASSOCIATED WITH THE PRODUCT.
Explanation of Carcinogenicity:NOT APPLICABLE FOR FINISHED PRODUCT
UNDER NORMAL CONDITIONS OF USE.
Effects of Overexposure:NONE EXPECTED FOR FINISHED PRODUCT UNDER NORMAL
CONDITIONS OF USE.
Medical Cond Aggravated by Exposure:NONE EXPECTED FOR FINISHED PRODUCT
UNDER NORMAL CONDITIONS OF USE.
======================= First Aid Measures =======================
First Aid:NONE EXPECTED FOR FINISHED PRODUCT UNDER NORMAL CONDITIONS OF
USE. INHALED-IF ACID VAPOR RELEASED, REMOVE PERSON TO FRESH AIR. IF
BREATHING IS DIFFICULT, ADMINISTER ARTIFICIAL RESPIRATION/ OXYGEN.
SEE K MEDICAL ATTENTION. EYES-IF ELECTROLYTE ENTERS EYES, FLUSH
WITH WATER FOR AT LEAST 15 MINUTES. SEEK PROMPT MEDICAL ATTENTION.
SKIN-IF ELECTROLYTE CONTACTS SKIN, FLUSH WITH MILD SOAP & WATER.
SEEK MED ICAL ATTENTION IF IRRITATION DEVELOPS. INGESTION- SEEK
PROMPT MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Extinguishing Media:MULTIPURPOSE DRY CHEMICAL OR MULTIPURPOSE CARBON
DIOXIDE (CO2).
Fire Fighting Procedures:BATTERY WILL BURN IF INVOLVED IN A FIRE.
EVACUATE AREA. SELF-CONTAINED BREATHING APPARATUS MUST BE WORN TO
PREVENT POSSIBLE INHALATION OF ACID MISTS, SMOKE AND DECOMPOSITION
PRODUCTS IN A FIRE. REMOVE ALL IGNITION SOURCES. COOL BATTERY (S)
TO PREVENT RUPTURE.
Unusual Fire/Explosion Hazard:HYDROGEN GAS MAY BE PRODUCED AND MAY
EXPLODE IF IGNITED. REMOVE ALL IGNITION SOURCES. VENTILATE AREA.
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID CONTACT WITH ACID MATERIALS. USE SODA
ASH, BAKING SODA OR LIME TO NEUTRALIZE ACID IF RELEASED.
Neutralizing Agent:SODA ASH, BAKING SODA, LIME.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT CARRY BATTERY BY TERMINALS. DO
NOT DROP BATTERY, PUNCTURE OR ATTEMPT TO OPEN BATTERY CASE. KEEP
AWAY FROM FLAMES DURING AND IMMEDIATELY AFTER CHARGE. AVOID
PROLONGED OVERCHARGES IN CONFINED ARE AS. STORE AT AMBIENT ROOM
TEMPERATURE. DO NOT SUBJECT PRODUCT TO OPEN FLAME OR FIRE.
Other Precautions:AVOID CONDITIONS WHICH COULD CAUSE ARCING BETWEEN
BATTERY TERMINALS. WASH HANDS THOROUGHLY BEFORE EATING OR SMOKING
AFTER HANDLING BATTERIES.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT NECESSARY UNDER NORMAL CONDITIONS OF USE FOR
FINISHED PRODUCT.
Ventilation:NOT NECESSARY UNDER NORMAL CONDITIONS OF USE FOR FINISHED
PRODUCT.
Protective Gloves:NOT NECESSARY UNDER NORMAL CONDITIONS OF USE FOR
FINISHED PRODUCT.
Eye Protection:NOT NECESSARY UNDER NORMAL CONDITIONS OF USE FOR
FINISHED PRODUCT.
Other Protective Equipment:NOT NECESSARY UNDER NORMAL CONDITIONS OF USE
FOR FINISHED PRODUCT.
Work Hygienic Practices:NOT NECESSARY UNDER NORMAL CONDITIONS OF USE
FOR FINISHED PRODUCT.
Supplemental Safety and Health
THE OPTIMA SEALED LEAD ACID BATTERY IS CONSIDERED AN ARTCLE AS DEFINED
BY 29 CFR 1910.1200 (C) OSHA HAZCOM. THE INFORMATION ON THIS SHEET
IS SUPPLIED AT THE CUSTOMER'S REQUEST FOR INFORMATION ONLY. DE
SCDRIPTION IN LOLA (DLSC) IS WRONG, WHICH DESCRIBES IT AS CLASS 8.
================== Physical/Chemical Properties ==================
HCC:Z4
Appearance and Odor:SEALED LEAD ACID BATTERY.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE STATED BY MANUFACTURER.
Stability Condition to Avoid:AVOID SHORTING, USE ONLY APPROVED CHARGING
METHODS. DO NOT PUNCTURE BATTERY CASE.
Hazardous Decomposition Products:NONE STATED BY MANUFACTURER.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
=================== Toxicological Information ===================
Toxicological Information:THREASHOLD LIMIT VALUE: NONE APPLICABLE FOR
FINISHED PRODUCT. ROUTE OF ENTRY: NONE APPLICABLE FOR FINISHED
PRODUCT UNDER NORMAL CONDITIONS OF USE. SIGNS OF SYMPTOMS OF ACUTE
EXPOSURE: NONE EXPECTED FO R FINISHED PRODUCT UNDER NORMAL
CONDITIONS OF USE. CHRONIC EXPOSURE: NONE EXPECTED FOR FINISHED
PRODUCT UNDER NORMAL CONDITIONS OF USE. EFFECTS OF OVEREXPOSURE,
CONDITIONS TO AVOID: NO EXPOSURE EXPEC TED FOR FINISHED
PRODUCT.HOWEVER, DO NOT PUNCTURE OR OPEN BATTERY CASE. ACID
ELECTROLYTE MAY BE RELEASED, WHICH IS CORROSIVE..
===================== Ecological Information =====================
Ecological:NONE STATED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS. SEND TO A LEAD RECYCLING FACILITY WHICH
FOLLOWS APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS FOR ROUTINE
DISPOSAL OF SPENT OR DAMAGED BATTERIES. THE DISTRIBUTOR/USER IS
RESPONSIBLE FOR ROUTINE DISPOSITION OF SPENT OR DAMAGED
BATTERIES.
=================== MSDS Transport Information ===================
Transport Information:SEALED LEAD ACID BATTERY IS NOT A US DOT
HAZARDOUS MATERIAL. UNDER DANGEROUS GOODS REGULATIONS, 38TH
EDITION, EFFECTIVE JANUARY 1, 1997, PRODUCED BY INTERNATIONAL AIR
TRANSPORTATION ASSOCIATION (IATA) : OPTIMA BATTERIES ARE CLASSIFIED
AS NON-REGULATED BY SPECIAL PROVISIONS A-48 AND A-67 FOR UN2800.
UNDER 49 CFR, MARCH 1, 1998 EDITION, OPTIMA BATTERIES ARE
CLASSIFIED AS AN EXCEPTION FROM ALL OTHER R EQUIREMENTS OR
CONDITIONS AS STATED IN: BATTERIES WET, 173.159 (D)(3(I)[VIBRATION
TEST], & (D)(3)(II)[PRESSURE DIFFERENTIAL TEST]. THESE CONDITIONS
HAVE BEEN TESTED & CERTIFIED.
===================== Regulatory Information =====================
SARA Title III Information:NONE STATED BY MANUFACTURER.
Federal Regulatory Information:ACCORDING TO THE OSHA HAZARD
COMMUNICATION STANDARD, SEALED LEAD ACID BATTERY IN ITS
MANUFACTURED AND SUPPLIED STATE IS CONSIDERED NON-HAZARDOUS.
State Regulatory Information:NONE STATED BY MANUFACTURER.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|