Search   
MSDS  
:
 198 3113, SYNTHETIC GREASE WITH FLUOROCARBON
CAS  
:
 9002-84-0
NAME  
:
 clay gel and antioxidant
polytetrafluoroethylene
=====================  Product Identification  =====================

MSDS NAME:198 3113, SYNTHETIC GREASE WITH FLUOROCARBON
Status Code:A
MSDS Number: CKMJZ
=== Responsible Party ===
Company:EASTMAN KODAK COMPANY
Address:343 STATE STREET
City:ROCHESTER
State:NY
ZIP:14650
Country:US
Info Phone Num:716-722-5151/(800) 242-2424
Emergency Phone Num:716 722-5151
Preparer's Name:NOT PROVIDED
CAGE:19139
=== Contractor Identification ===
Company:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139

=============  Composition/Information on Ingredients  =============

Name:CLAY GEL AND ANTIOXIDANT
Minumum % Wt:90.
Maxumum % Wt:95.
Other REC Limits:NOT PROVIDED

Name:POLYTETRAFLUOROETHYLENE
CAS:9002-84-0
RTECS #:KX4025000
Minumum % Wt:5.
Maxumum % Wt:10.
Other REC Limits:NOT PROVIDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NOT PROVIDED
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF EXPOSURE: INHALATION: LOW
    HAZARD FOR RECOMMENDED HANDLING. EYES: NO SPECIFIC HAZARD KNOWN.
    MAY CAUSE TRANSIENT IRRITATION. SKIN: LOW HAZARD FOR RECOMMENDED
    HANDLING. INGESTION: EXPECTED TO  BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:(COMPONENTS PRESENT AT 0.1% OR MORE):
    INTERNATIONAL AGENCY FOR RESEARCH ON CANCER (IARC): NONE. AMERICAN
    CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS (ACGIH): NONE.
    NATIONAL TOXICOLOGY PROGRAM (NT P): NONE. OCCUPATIONAL SAFETY AND
    HEALTH ADMINISTRATION (OSHA): NONE.
Effects of Overexposure:EYES: MAY CAUSE TRANSIENT IRRITATION.
Medical Cond Aggravated by Exposure:NOT PROVIDED

=======================  First Aid Measures  =======================

First Aid:INHALATION: IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
    ATTENTION IF SYMPTOMS PERSIST. EYES: ANY MATERIAL THAT CONTACTS THE
    EYE SHOULD BE WASHED OUT IMMEDIATELY WITH WATER. GET MEDICAL
    ATTENTION IF  SYMPTOMS OCCUR. SKIN: WASH WITH SOAP AND WATER. GET
    MEDICAL ATTENTION IF SYMPTOMS OCCUR. INGESTION: DRINK 1-2 GLASSES
    OF WATER. SEEK MEDICAL ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO
    AN UNCONSCIOUS  PERSON.

=====================  Fire Fighting Measures  =====================

Flash Point:=235.C, 455.F
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, CARBON DIOXIDE (CO2),
    FOAM.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
    DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:CAUTION: CONTAMINATED SURFACES MAY BE
    SLIPPERY. ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL,
    THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE.
Neutralizing Agent:NOT RELEVANT

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE WITH ADEQUATE VENTILATION. WASH
    THOROUGHLY AFTER HANDLING. KEEP FROM CONTACT WITH OXIDIZING
    MATERIALS. KEEP CONTAINER CLOSED.
Other Precautions:NOT PROVIDED

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES PER
    HOUR) SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO
    CONDITIONS.
Protective Gloves:FOR PROLONGED OR REPEATED SKIN CONTACT, IMPERVIOUS
    GLOVES SHOULD BE WORN.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS (OR GOGGLES).
Other Protective Equipment:EYEBATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:IT IS A GOOD INDUSTRIAL HYGIENE PRACTICE TO
    MINIMIZE EYE AND SKIN CONTACT.
Supplemental Safety and Health
NONE

==================  Physical/Chemical Properties  ==================

HCC:V5
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:B.P. Text:NOT AVAILABLE
Melt/Freeze Pt:M.P/F.P Text:NOT PROVIDED
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Pres:NEGLIGIBLE
Vapor Density:>1
Spec Gravity:NOT AVAILABLE
pH:NOT AVAILABLE
Viscosity:NOT PROVIDED
Evaporation Rate & Reference:NOT PROVIDED
Solubility in Water:INSOLUBLE
Appearance and Odor:PHYSICAL FORM: GREASE COLOR: COLORLESS ODOR: SLIGHT
Percent Volatiles by Volume:NEGLIGIBLE

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NOT PROVIDED
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
    HYDROGEN FLUORIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

===================  Toxicological Information	===================

Toxicological Information:EFFECTS OF EXPOSURE: INHALATION: LOW HAZARD
    FOR RECOMMENDED HANDLING. EYES: NO SPECIFIC HAZARD KNOWN. MAY CAUSE
    TRANSIENT IRRITATION. SKIN: LOW HAZARD FOR RECOMMENDED HANDLING.
    INGESTION: EXPECTED TO  BE A LOW INGESTION HAZARD.

=====================  Ecological Information  =====================

Ecological:THIS MATERIAL HAS NOT BEEN TESTED FOR ENVIRONMENTAL EFFECTS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
    TO NATIONAL, STATE, OR LOCAL LAWS. INCINERATE.

===================  MSDS Transport Information  ===================

Transport Information:FOR TRANSPORTATION INFORMATION REGARDING THIS
    MATERIAL, PLEASE PHONE THE IRREGULAR SHIPPING DEPARTMENT (716)
    722-1732.

=====================  Regulatory Information  =====================

SARA Title III Information:CHEMICAL(S) SUBJECT TO THE REPORTING
    REQUIREMENTS OF SECTION 313 OF TITLE III OF THE SUPERFUND
    AMENDMENTS AND REAUTHORIZATION ACT (SARA) OF 1986 AND 40 CFR PART
    372: NONE.
Federal Regulatory Information:NOT PROVIDED
State Regulatory Information:MATERIAL(S) KNOWN TO THE STATE OF
    CALIFORNIA TO CAUSE CANCER: NONE. MATERIAL(S) KNOWN TO THE STATE OF
    CALIFORNIA TO CAUSE ADVERSE REPRODUCTIVE EFFECTS: NONE.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
LEAD/ACID STORAGE BATTERY 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
7440-31-5
BUFFER PE,QIAQUICK GEL EXTRACTION KIT,28704,28706 77-86-1
7647-01-0
METCO 72F-NS 12070-12-1
7440-48-4
7439-89-6
BUFFER PE,(CONCENTRATE)QIAPREP SPIN MINIPREP KIT, 27104 77-86-1
7647-01-0
BUFFER P1,PLASMID DNA COMBI KIT, 12169 7647-01-0
60-00-4
ISONEL 31 1330-20-7
64742-88-7
BUFFER P1,PLASMID MEGA KIT, 12181,12183 7647-01-0
60-00-4
BUFFER P3, QIAWELL 8 ULTRA PLASMID KIT 16152, 16154, 16155 64-19-7
BUFFER P1, PLASMID GIGA KIT, 12191 7647-01-0
60-00-4
POVIDONE IODINE SWAB/SCRUB/OINTMENT/PREP 25655-41-8
BUFFER P1,QIAFILTER PLASMID MIDI KIT,12243,12245 7647-01-0
60-00-4
198 3113, SYNTHETIC GREASE WITH FLUOROCARBON 9002-84-0
BUFFER P1,QIAFILTER PLASMID MAXI KIT, 12262,12263 7647-01-0
60-00-4
BUFFER P3, QIAWELL 96 ULTRA PLASMID KIT 16190,16191, 16193 64-19-7
BUFFER PE,(CONCENTRATE) QIAWELL 8 ULTRA BIOROBOT KIT,960134 77-86-1
7647-01-0
BUFFER P1, QIAFILTER PLASMID MEGA KIT, 12281 7647-01-0
60-00-4
BUFFER P3, QIAWELL 8 PLASMID KIT 17122, 17124, 17125 64-19-7
GAMAZYME 700 FN
BUFFER PE,(CONCENTRATE) 96 ULTRA BIOROBOT KIT,960141 77-86-1
7647-01-0
ISOPROPYL ALCOHOL 67-63-0
179 0567, N-9 67-64-1
7732-18-5
108-39-4
BUFFER P3, PLASMID BUFFER SET 19046 64-19-7
BUFFER P3, ENDOFREE PLASMID BUFFER SET 19048 64-19-7
E511-100, EOSIN Y 17372-87-1
BUFFER P3 19053 64-19-7
BUFFER P3, QIAWELL 8 ULTRA BIOROBOT KIT 960134 64-19-7
BUFFER PE,(CONCENTRATE) 96 PCR BIOROBOT KIT,96141 77-86-1
7647-01-0
BUFFER P3, QIAWELL 96 ULTRA BIOROBOT 960141 64-19-7
BUFFER P1, QIAFILTER PLASMID GIGA KIT, 12291 7647-01-0
60-00-4
844 4572, EKTACOLOR RA BLEACH FIX DESILVERING CONCENTRATE 7732-18-5
5964-35-2
1310-58-3
BUFFER P1,ENDOFREE PLASMID MAXI KIT, 12362 7647-01-0
60-00-4
LYSE S III LYTIC REAGENT (1L) 151-50-8
67-63-0
BUFFER P1, ENDOFREE PLASMID MEGA KIT, 12381 7647-01-0
60-00-4
LEAD-ACID BATTERY, NP4-12 7439-92-1
7440-36-0
7440-38-2
7440-70-2
7440-31-5
7664-93-9
9003-07-0
9003-53-6
9003-54-7
9003-56-9
9003-55-8
9002-86-2
60676-86-0
121 0715, KODAK EXPLORATION DEVELOPER AND REPLENISHER GDR 10117-38-1
123-31-9
1310-58-3
540-72-7
BUFFER PE,(CONCENTRATE) QIAPREP 8 TURBO BIOROBOT KIT,962134 77-86-1
7647-01-0
XD-45, DEVELOPER-SOLID MIXTURE 7439-89-6
9010-88-2
25213-39-2
1333-86-4
68611-44-9
557-05-1
BUFFER P1,QIAWELL 8 PLUS PLASMID KIT,16142,16144,16145 7647-01-0
60-00-4
XD-48, DEVELOPER-SOLID MIXTURE 7439-89-6
9010-88-2
25213-39-2
1333-86-4
68611-44-9
557-05-1
805 2011, KC-74 67135-48-2
XD-50, DEVELOPER-SOLID MIXTURE 7439-89-6
9010-88-2
25213-39-2
1333-86-4
68611-44-9
557-05-1
RTV SILICONE ADHESIVE (AI 100 SILICONE) 4253-34-3
17689-77-9
7631-86-9
BUFFER PE,(CONCENTRATE) QIAPREP 96 TURBO BIOROBOT KIT,962141 77-86-1
7647-01-0
843 9531, UNISYS DEVELOPER 7439-89-6
25767-47-9
1333-86-4
TECH TIRE AND TUBE COMPOUND, 722 102-71-6
112-80-1
TECH TIRE AND TUBE COMPOUND, 722L 102-71-6
112-80-1
TECH TIRE AND TUBE COMPOUND, 723L 102-71-6
112-80-1
BUFFER P1,QIAWELL ULTRA PLASMID KIT,16152,16154,16155 7647-01-0
60-00-4
BUFFER P1,QIAWELL 96 ULTRA PLASMID KIT,16190,16191,16193 7647-01-0
60-00-4
BUFFER P1,QIAWELL 8 PLASMID KIT,17122,17124,17125 7647-01-0
60-00-4

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net