===================== Product Identification =====================
MSDS NAME:E-58D EMULSIFIER, (SEE SUPPL)
NIIN:01-266-4551
Status Code:A
Kit Part:Y
MSDS Number: CLGXN
=== Responsible Party ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID STREET
City:SANTA MONICA
State:CA
ZIP:90404-3723
Country:US
Info Phone Num:213-450-1111
Emergency Phone Num:310-450-1111
Chemtrec Ind/Phone:(800)424-9300
CAGE:98733
=== Contractor Identification ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID ST
Box:00000
City:SANTA MONICA
State:CA
ZIP:90404
Country:US
Phone:310-450-1111/FAX 310452-4046
Contract Num:SP0450-01-M-ZE67
CAGE:98733
============= Composition/Information on Ingredients =============
Name:ETHYLENE GLYCOL
CAS:107-21-1
RTECS #:KW2975000
Minumum % Wt:65.
Maxumum % Wt:80.
OSHA PEL:50 PPM
ACGIH TLV:100 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT: LIQUID MAY CAUSE
IRRITATION, REDNESS, TEARING, STINGING, AND SWELLING OF EYES. SKIN
CONTACT: MAY CAUSE SKIN IRRITATION WITH PROLONGED OR REPEATED
CONTACT. SWALLOWING: SMALL AMOUNTS MAY NO T PRODUCE HARMFUL
EFFECTS. LARGE AMOUNTS MAY BE HARMFUL. INHALATION: SMALL AMOUNTS
MAY NOT BE HARMFUL. LARGE AMOUNTS MAY BE HARMFUL. TARGET ORGANS:
OVER EXPOSURE TO COMPONENTS OF THIS MATERIAL CAN EF FECT KIDNEYS
AND LIVER.
Explanation of Carcinogenicity:THIS MATERIAL IS NOT KNOWN TO CONTAIN
ANY CONSTITUENTS LISTED AS A CARCINOGEN BY THE INTERNATIONAL AGENCY
FOR RESEARCH ON CANCER, NATIONAL TOXICOLOGY PROGRAM, OR OSHA.
Effects of Overexposure:EYE CONTACT:IRRITATION, REDNESS, TEARING,
STINGING, AND SWELLING OF EYES. SKIN CONTACT: IRRITATION, REDNESS,
AND BURNING OF SKIN. SWALLOWING AND INHALATION: STOMACH OR
INTESTINAL UPSET (NAUSEA, VOMIT ING, DIARRHEA), IRRITATION (NOSE,
THROAT, AIRWAYS), CENTRAL NERVOUS SYSTEM DEPRESSION (DIZZINESS,
DROWSINESS, FATIGUE, HEADACHE, UNCONSCIOUSNESS).
======================= First Aid Measures =======================
Eyes: FLUSH WITH WATER FOR 15 MINUTES. HOLD EYELIDS OPEN.
SEEK MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING. WASH
EXPOSED SKIN AREA WITH SOAP AND WATER. IF SYMPTOMS PERSIST, SEEK
MEDICAL ATTE NTION. LAUNDER CONTAMINATED CLOTHES AND CLEAN SHOES
BEFORE REUSE. SWALLOWING: CALL A PHYSICIAN. IF DROWSY OR
UNCONSCIOUS, DO NOT GIVE ANYTHING BY MOUTH; PLACE ON LEFT SIDE WITH
HEAD DOWN. DO NOT LEAVE UNATTENDED. INHALATION: MOVE TO FRESH AIR.
IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING
DIFFICULT, GIVE OXYGEN. GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:=111.1C, 232.F
Autoignition Temp:=397.8C, 748.F
Lower Limits:3.2
Upper Limits:15.3
Extinguishing Media:WATER FOG, DRY CHEMICAL, CARBON DIOXIDE, OR FOAM.
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE. WATER SPRAY MAY BE
USED TO KEEP FIRE EXPOSED CONTAINERS COOL. WEAR FULL PROTECTIVE
CLOTHING AND NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH
FULL FACE PIECE OPERATE D IN THE PRESSURE DEMAND OR OTHER POSITIVE
PRESSURE MODE.
Unusual Fire/Explosion Hazard:EMPTY CONTAINERS MAY CONTAIN VAPORS. MAY
FORM CARBON DIOXIDE AND CARBON MONOXIDE.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
ISOLATE AREA. WEAR PROTECTIVE GEAR, KEEP UNECESSARY PERSONNEL AWAY.
CONTAIN AND RECOVER LIQUID WHEN POSSIBLE. COLLECT LIQUID IN AN
APPROPRIATE CONTAINER OR ABSORB WITH INERT MATERIAL SUCH AS
VERMICULITE, DRY SAND, OR EARTH. DO NOT USE COMBUSTIBLE MATERIALS.
PLACE IN A CHEMICAL WASTE CONTAINER. DO NOT FLUSH TO SEWER.
====================== Handling and Storage ======================
Handling and Storage Precautions:PROTECT AGAINST PHYSICAL DAMAGE. STORE
IN COOL, DRY, WELL-VENTILATED LOCATION AWAY FROM AREA WHERE FIRE
HAZARDS MAY EXIST. STORE AND USE IN NO SMOKING AREA. EMPTY
CONTAINERS MAY CONTAIN RESIDUE LIQUID AND VAPORS. FOR INDUSTRIAL
USE ONLY. KEEP AWAY FROM CHILDREN.
Other Precautions:ANY USE OF THIS PRODUCT IN ELEVATED TEMPERATURE
PROCESSING SHOULD BE THOROUGHLY EVALUATED TO ESTABLISH AND MAINTAIN
SAFE OPERATING CONDITIONS. NOTE: MSDS INFORMATION IS FOR AS
SUPPLIED CONCENTRATE AND MAY NOT BE APPLICABLE TO THE IN USE
MATERIAL, WHICH IS USED IN WATER AT 20% CONCENTRATION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:PERSONAL RESPIRATORS (NIOSH APPROVED) IF
EXPOSURE LIMIT IS EXCEEDED.
Ventilation:A SYSTEM OF LOCAL OR GENERAL EXHAUST IS RECOMMENDED TO KEEP
EMPLOYEE EXPOSURE BELOW THE AIRBORNE EXPOSURE LIMITS. LOCAL EXHAUST
IS PREFERRED.
Protective Gloves:WEAR RESISTANT GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES, SAFETY GLASSES OR FULL FACE
SHIELD.
Other Protective Equipment:TO PREVENT REPEATED OR PROLONGED SKIN
CONTACT, WEAR IMPERVIOUS CLOTHING AND BOOTS. EYE WASH AND
QUICK-DRENCH FACILITIES SHOULD BE NEAR WORK AREA.
Work Hygienic Practices:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Supplemental Safety and Health
PRODUCT CODE: E-58D. GENERAL OR GENERIC ID: AMS-2644 TYPE I, METHOD D,
PENETRANT EMULSIFIER. THIS ENTRY DESCRIBES THE PENETRANT
EMULSIFIER, (SERIAL NUMBER CLGXN), PART OF A TWO PART KIT. SEE THIS
SAME NSN, (SERIAL NUMBER CLGXS, PENETRANT), FOR OTHER PART OF KIT.
================== Physical/Chemical Properties ==================
HCC:V5
Spec Gravity:1.12 KG/L@ 60F(9.3LBS/GAL
Solubility in Water:COMPLETE (100%)
Appearance and Odor:PINKISH RED LIQUID; MILD ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID STRONG ACIDS, ALKALIES, AND OXIDIZING MATERIALS.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:MAY FORM CARBON DIOXIDE AND CARBON
MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
=================== Toxicological Information ===================
Toxicological Information:NO DATA AVAILABLE ON PRODUCT.
===================== Ecological Information =====================
Ecological:NO DATA AVAILABLE ON PRODUCT.
==================== Disposal Considerations ====================
Waste Disposal Methods:PROCESSING, USE, OR CONTAMINATION OF THIS
PRODUCT MAY CHANGE THE WASTE MANAGEMENT OPTIONS. STATE AND LOCAL
DISPOSAL REGULATIONS MAY DIFFER FROM FEDERAL DISPOSAL REGULATIONS.
DISPOSE OF CONTAINER AND U NUSED CONTENTS IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REQUIREMENTS.
=================== MSDS Transport Information ===================
Transport Information:THIS PRODUCT IS SHIPPED IN 5 GALLON CANS, 46.5
POUNDS, AND THERFORE DOES NOT MEET THE DEFINITION OF A CLASS 9
ITEM, SINCE THE RQ FOR ETHYLENE GLYCOL IS 5000 POUND.
MANUFACTURER'S MSDS STATES THE DOT PROPER SHIPPING NAME "OTHER
REGULATED SUBSTANCES, LIQUID, N.O.S., 9, NA3082, III" AND
REPORTABLE QUANTITY-49 CFR 172.101: 5000 LBS. ETHYLENE GLYCOL. THIS
IS FOR 5000 POUNDS AND HIGHER BULK SHIPMENTS.
===================== Regulatory Information =====================
SARA Title III Information:SARA 313 COMPONENTS-40 CFR 372.65: ETHYLENE
GLYCOL, CAS# 107-21-1, <80%. SARA 302 COMPONENTS-40 CFR 355
APPENDIX A : NONE. SARA SECTION 311/312 HAZARD CLASS-40 CFR 370.2:
IMMEDIATE; DELAYED.
Federal Regulatory Information:TSCA: LISTED. CERCLA RQ-40 CFR 302.(A):
ETHYLENE GLYCOL, RQ: 5000 LBS. MISCELLANEOUS INFORMATION:PRODUCT
LISTED ON QPL FOR AMS-2644. MEETS AMS-2647, ASME BOILER AND
PRESSURE VESSEL CODE, ASTM E-165, A STM E-1417, NAVSEA 250-1500-1,
AND AEROSPACE OEM SPECIFICATIONS FOR PENETRANT INSPECTION.
State Regulatory Information:CALIFORNIA PROPOSITION 65 REQUIRES THE
FOLLOWING STATEMENT-PRODUCT MAY CONTAIN DETECTABLE AMOUNTS OF
SUBSTANCES KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER: (1,4
DIOXANE), (ETHYLENE GLYCOL), (ACE TALDEHYDE). NEW JERSEY R-T-K
LABEL: ETHYLENE GLYCOL, CAS# 107-21-1. PENNSYLVANIA R-T-K LABEL:
1,2-ETHANEDIOL.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|