Search   
MSDS  
:
 LEAD-ACID BATTERY (ELECTRIC STORAGE BATTERY)
CAS  
:
 7439-92-1
7440-36-0
7440-31-5
7440-70-2
7440-38-2
7664-93-9
9003-07-0
NAME  
:
 inorganic compounds of lead
inorganic compounds of antimony
inorganic compounds of tin
inorganic compounds of calcium
inorganic compounds of arsenic
electrolyte (sulfuric acid + water solution)
case material: polypropylene or hard rubber
=====================  Product Identification  =====================

MSDS NAME:LEAD-ACID BATTERY (ELECTRIC STORAGE BATTERY)
NIIN:01-031-6877
Status Code:A
MSDS Number: CLHBD
=== Responsible Party ===
Company:EXIDE CORP
Address:645 PENN STREET
Box:14205
City:READING
State:PA
ZIP:19612-4205
Country:US
Info Phone Num:610-378-0500/0798
Emergency Phone Num:(800) 424-9300
Preparer's Name:ENVIRONMENTAL DEPARTMENT
Chemtrec Ind/Phone:(800)424-9300
CAGE:20038
=== Contractor Identification ===
Company:BATTERY OUTLET OF HAMPTON INC
Address:2815 GEORGE WASHINGTON HWY
Box:City:TABB
State:VA
ZIP:23602
Country:US
Phone:804-867-8280
Contract Num:SP0411-01-M-EQ01
CAGE:0FTM0
Company:BELL CITY BATTERY MFG INC
Address:915 S CHARLES ST
Box:City:BELLEVILLE
State:IL
ZIP:62220-2605
Country:US
Phone:618-234-7272
Contract Num:SP0430-01-M-FN97
CAGE:0ABZ3
Company:EXIDE CORP
Address:645 PENN STREET
Box:14205
City:READING
State:PA
ZIP:19612-4205
Country:US
Phone:610-378-0500/0798
CAGE:20038

=============  Composition/Information on Ingredients  =============

Name:INORGANIC COMPOUNDS OF LEAD
CAS:7439-92-1
RTECS #:OF7525000
Minumum % Wt:54.
Maxumum % Wt:62.
ACGIH TLV:0.15 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:INORGANIC COMPOUNDS OF ANTIMONY
CAS:7440-36-0
RTECS #:CC4025000
= Wt:.4
OSHA PEL:0.5 MG/M3
ACGIH TLV:0.5 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:INORGANIC COMPOUNDS OF TIN
CAS:7440-31-5
RTECS #:XP7320000
= Wt:.16
ACGIH TLV:2 MG/M3

Name:INORGANIC COMPOUNDS OF CALCIUM
CAS:7440-70-2
RTECS #:EV8040000
= Wt:.02

Name:INORGANIC COMPOUNDS OF ARSENIC
CAS:7440-38-2
RTECS #:CG0525000
= Wt:.01
ACGIH TLV:0.01 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:ELECTROLYTE (SULFURIC ACID + WATER SOLUTION)
CAS:7664-93-9
RTECS #:WS5600000
Minumum % Wt:26.
Maxumum % Wt:40.
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3
ACGIH STEL:3 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:CASE MATERIAL: POLYPROPYLENE OR HARD RUBBER
CAS:9003-07-0
RTECS #:UD1842000
Minumum % Wt:5.
Maxumum % Wt:12.

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NO DATA PROVIDED BY MANUFACTURER
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MAY CAUSE SEVERE
    RESPIRATORY IRRITATION. DUST/FUMES MAY CAUSE UPPER RESPIRATORY
    TRACT & LUNG IRRITATION.  INGESTION: MAY CAUSE SEVERE IRRITATION OF
    MOUTH, THROAT, ESOPHAGUS & STOMACH. MAY  LEAD TO SYSTEMIC TOXICITY.
    MAY CAUSE ABDOMINAL PAIN, NAUSEA, VOMITING, DIARRHEA & SEVERE
    CRAMPING.  SKIN: SEVERE IRRITATION, BURNS & ULCERATION.  EYES:
    SEVERE IRRITATION, BURNS, CORNEA DAMAGE, BLINDNE SS.
Explanation of Carcinogenicity:ELECTROYLYTE (WATER & SULFURIC ACID
    SOLUTION): THE INTERNATIONAL AGENCY FOR RESEARCH ON CANCER (IARC)
    HAS CLASSIFIED "STRONG INORGANIC ACID MIST CONTAINING SULFURIC
    ACID" AS A CATEGORY I CARCINOGEN, A  SUBSTANCE THAT IS CARCINOGENIC
    TO HUMANS. THIS CLASSIFICATION DOES NOT APPLY TO SULFURIC ACID
    SOLUTIONS IN STATIC LIQUID STATE OR TO ELECTROLYTE IN BATTERIES.
Effects of Overexposure:ACUTE-ELECTROLYTE (WATER & SULFURIC ACID
    SOLUTION): SEVERE SKIN IRRITATION, DAMAGE TO CORNEA MAY CAUSE
    BLINDNESS, UPPER RESPIRATORY IRRITATION. LEAD COMPOUNDS: SYMPTOMS
    OF TOXICITY INCLUDE HEADACHE, F ATIGUE, ABDOMINAL PAIN, LOSS OF
    APPETITE, MUSCULAR ACHES AND WEAKNESS, SLEEP DISTURBANCES AND
    IRRITABILITY. CHRONIC- ELECTROLYTE (WATER & SULFURIC ACID
    SOLUTION): POSSIBLE EROSION OF TOOTH ENAMEL; INF LAMMATION OF NOSE,
    THROAT & BRONCHIAL TUBES. LEAD COMPOUNDS: ANEMIA; NEUROPATHY,
    PARTICULARLY OF THE MOTOR NERVES, WITH WRIST DROP; KIDNEY DAMAGE;
    REPRODUCTIVE CHANGES IN BOTH MALES AND FEMALES.
Medical Cond Aggravated by Exposure:SULFURIC ACID MIST MAY AGGRAVTE
    PULMONARY CONDITIONS. ELECTROLYTE MAY AGGRAVATE SKIN DISEASES SUCH
    AS ECZEMA & CONTACT DERMATITIS. LEAD CAN AGGRAVATE SOME FORMS OF
    KIDNEY, LIVER & NEUROLOGIC DISEASES.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE TO FRESH AIR IMMEDIATELY. IF BREATHING IS
    DIFFICULT, GIVE OXYGEN. GARGLE, WASH NOSE & LIPS IF LEAD INHALED. 
    INGESTION: GIVE LARGE QUANTITIES OF WATER; DO NOT INDUCE VOMITING;
    CONSU LT PHYSICIAN IMMEDIATELY.  SKIN: FLUSH WITH LARGE AMOUNTS OF
    WATER TO REMOVE ELECTROLYTE FOR AT LEAST 15 MINUTES & REMOVE
    CONTAMINATED CLOTHING/SHOES. WASH AWAY LEAD WITH SOAP & WATER. 
    EYES: FLUSH IM MEDIATELY WITH LARGET AMOUNTS OF WATER FOR AT LEAST
    15 MINUTES; CONTACT PHYSICIAN IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Lower Limits:4.1%, H2 GAS
Upper Limits:74.2%,H2 GAS
Extinguishing Media:CO2; FOAM; DRY CHEMICAL.
Fire Fighting Procedures:USE POSITIVE PRESSURE, SCBA. BEWARE OF ACID
    SPLATTER DURING WATER APPLICATION & WEAR ACID-RESISTANT CLOTHING,
    GLOVES, FACE & EYE PROTECTION. IF BATTERIES ARE ON CHARGE, SHUT OFF
    POWER TO THE CHARGING  EQUIPMENT, BUT, NOTE THAT STRINGS OF SERIES
    CONNECTED BATTERIES MAY STILL POSE RISK OF ELECTRIC SHOCK.
Unusual Fire/Explosion Hazard:IN OPERATION, BATTERIES GENERATE &
    RELEASE FLAMMABLE HYDROGEN GAS. THEY MUST ALWAYS BE ASSUMED TO
    CONTAIN THIS GAS WHICH, IF IGNITED BY BURNING CIGARETTE, NAKED
    FLAME OR SPARK, MAY CAUSE BATTERY EXPLO SION W/DISPERSION OF CASING
    FRAGMENTS & CORROSIVE LIQUID ELECTROLYTE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP FLOW OF MATERIAL, CONTAIN/ABSORB SMALL
    SPILLS W/ DRY SAND, EARTH, VERMICULITE. DO NOT USE COMBUSTIBLE
    MATERIALS. IF POSSIBLE, CAREFULLY NEUTRALIZE SPILLED ELECTROLYTE W/
    SODA ASH, SODIUM BICARBON ATE, LIME, ETC. WEAR ACID-RESISTANT
    CLOTHING, BOOTS, GLOVES & FACE SHIELD. DO NOT ALLOW DISCHARGE OF
    UN-NEUTRALIZED ACID TO SEWER. NEUTRALIZED ACID MUST BE MANAGED
    I/A/W APPLICABLE LAWS.
Neutralizing Agent:CAREFULLY NEUTRALIZE SPILLED ELECTROLYTE WITH SODA
    ASH, SODIUM BICARBONATE, LIME, ETC.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE BATTERIES UNDER ROOF IN COOL,
    DRY, WELL-VENTILATED AREAS WHICH ARE SEPARATED FROM INCOMPATIBLE
    MATERIALS & FROM ACTIVITIES WHICH MAY CREATE FLAMES, SPARKS OR
    HEAT. STORE ON SMOOTH, IMPERVIOUS SU RFACES WHICH ARE PROVIDED WITH
    MEASURES FOR LIQUID CONTAINMENT IN THE EVENTT OF ELECTROLYTE
    SPILLS.
Other Precautions:KEEP AWAY FROM METALLIC OBJECTS WHICH COULD BRIDGE
    THE TERMINALS ON A BATTERY & CREATE A DANGEROUS SHORT-CIRCUIT.
    HANDLE CAREFULLY & AVOID TIPPING, WHICH MAY ALLOW ELECTROLYTE
    LEAKAGE. SINGLE BATTERIE S POSE NO RISK OF ELECTRIC SHOCK BUT THERE
    MAY BE INCREASING RISK OF ELECTRIC SHOCK FROM STRINGS OF  CONNECTED
    BATTERIES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS. WHEN
    CONCENTRATIONS OF SULFURIC ACID MIST ARE KNOWN TO EXCEED PEL, USE
    NIOSH OR MSHA-APPROVED RESPIRATORY PROTECTION.
Ventilation:STORE AND HANDLE IN WELL-VENTILATED AREA. IF MECHANICAL
    VENTILATION IS USED, COMPONENTS MUST BE ACID-RESISTANT.
Protective Gloves:RUBBER OR PLASTIC ACID-RESISTANT GLOVES WITH
    ELBOW-LENGTH GAUNTLET.
Eye Protection:CHEMICAL GOGGLES OR FACE SHIELD.
Other Protective Equipment:ACID-RESISTANT APRON. UNDER SEVERE EXPOSURE
    OR EMERGENCY CONDITIONS, WEAR ACID-RESISTANT CLOTHING, GLOVES &
    BOOTS.
Work Hygienic Practices:HANDLE BATTERIES CAUTIOUSLY, DO NOT TIP TO
    AVOID SPILLS. MAKE CERTAIN VENT CAPS ARE ON SECURELY. AVOID BODILY
    CONTACT W/ INTERNAL COMPONENTS. WEAR PROTECTIVE CLOTHING, EYE &
    FACE PROTECTION, WHEN FILLIN
Supplemental Safety and Health
IN AREAS WHERE WATER & SULFURIC ACID SOLUTIONS ARE HANDLED IN
    CONCENTRATIONS GREATER THAN 1%, EMERGENCY EYEWASH STATIONS AND
    SHOWERS SHOULD BE PROVIDED, WITH UNLIMITED WATER SUPPLY.

==================  Physical/Chemical Properties  ==================

HCC:C1
Boiling Pt:=95.C, 203.F
B.P. Text:203-240 (FOR S.G. RANG
Vapor Pres:17 TO 11 (FOR S.G. RANGE)
Vapor Density:>1
Spec Gravity:1.230 TO 1.350
Solubility in Water:100%
Appearance and Odor:CLEAR LIQUID W/ A SHARP, PENETRATING, PUNGENT ODOR.
    A BATTERY IS A

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ELECROLYTE (WATER & SULFURIC ACID SOLUTION):CONTACT W/ COMBUSTIBLES &
    ORGANIC MATERIALS MAY CAUSE FIRE & EXPLOSION. ALSO REACTS VIOLENTLY
    W/ STRONG REDUCING AGENTS, METALS, SULFUR TRIOXIDE GAS, STRONG
    OXIDIZERS & WATER.
Stability Condition to Avoid:PROLONGED OVERCHARGE AT HIGH CURRENT;
    SOURCES OF IGNITION.
Hazardous Decomposition Products:ELECTROLYTE (WATER & SULFURIC ACID
    SOLUTION): SULFUR TRIOXIDE, CARBON MONOXIDE, SULFURIC ACID MIST,
    SULFUR DIOXIDE, HYDROGEN SULFIDE.

===================  Toxicological Information	===================

Toxicological Information:NO DATA PROVIDED BY MANUFACTURER

=====================  Ecological Information  =====================

Ecological:NO DATA PROVIDED BY MANUFACTURER

====================  Disposal Considerations  ====================

Waste Disposal Methods:SPENT BATTERIES: SEND TO SECONDARY LEAD SMELTER
    FOR RECYCLING. ELECTROLYTE: PLACE NEUTRALIZED SLURRY INTO SEALED
    ACID RESISTANT CONTAINERS & DISPOSE OF AS HAZARDOUS WASTE, AS
    APPLICABLE. LARGE WATER-D ILUTED SPILLS, AFTER NEUTRALIZATION &
    TESTING, SHOULD BE MANAGED IN ACCORDANCE WITH APPROVED LOCAL, 
    STATE & FEDERAL REQUIREMENTS. CONSULT AUTHORITIES.

===================  MSDS Transport Information  ===================

Transport Information:BATTERY, WET, FILLED WITH ACID; CLASS 8; UN2794,
    PG III; CORROSIVE

=====================  Regulatory Information  =====================

SARA Title III Information:EPCRA SECTION 302 NOTIFICATION IS REQUIRED
    IF 1,000 LBS OR MORE OF SULFURIC ACID IS PRESENT.  SULFURIC ACID IS
    LISTED "EXTREMELY HAZARDOUS SUBSTANCE" UNDER EPCRA.  EPCRA SECTION
    312 TIER TWO REPORTING  IS REQUIRED FOR NON-AUTOMOTIVE BATTERIES IF
    SULFURIC ACID IS PRESENT IN QUANTITIES OF 500 LBS OR MORE AND/OR IF
    LEAD IS PRESENT IN QUANTITIES OF 10,000 LBS OR MORE. THIS PRODUCT
    CONTAINS TOXIC CHEMIC ALS WHICH MAY BE REPORTABLE UNDER DPCRA
    SECTION 313: LEAD, CAS# 7439-92-1, 54-62%; SULFURIC ACID/WATER
    SOLUTION, CAS# 7664-93-9, 26-40%; ANTIMONY, CAS# 7440-36-0, 0.4%;
    ARSENIC, CAS# 7440-38-2, 0.01%.
Federal Regulatory Information:INGREDIENTS IN EXIDE'S BATTERIES ARE
    LISTED IN THE TSCA REGISTRY AS FOLLOWS: SULFURIC ACID, LEAD, LEAD
    OXIDE, LEAD SULFATE, ANTIMONY, ARSENIC, CALCIUM, & TIN.
State Regulatory Information:CALIFORNIA PROPOSITION 65: THIS PRODUCT
    CONTAINS LEAD, A CHEMICAL KNOWN TO THE SATE OF CALIFORNIA TO CAUSE
    CANCER, OR BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
FP-97A(M) FLUORESCENT PENETRANT, (SEE SUPPL) 64742-46-7
146 3462,KODAK SODIUM CARBONATE (MONOHYDRATES) 5968-11-6
STANNOUS CHLORIDE S4760 10025-69-1
CHLORIDE 2 INDICATOR, #1043 7789-00-6
144-55-8
7631-86-9
PHOSVER 3, #2209 7790-62-7
50-81-7
7631-95-0
D-70 PENETRANT DEVELOPER 67-63-0
AC-4220, ETHYLENEDIAMINE (SEE SUPPL) 107-15-3
ACETONE (SEE SUPPL) 67-64-1
71-43-2
HEX, (SEE SUPPL) 5197-80-8
9016-45-9
DOW CORNING OS-20 107-51-7
AMMONIUM CHLORIDE (SEE SUPPL) 12125-02-9
CUPRIC SULFATE, 5 HYDRATE (SEE SUPPL) 7758-99-8
SODIUM HYDROXIDE, 1.0 NORMAL SOLUTION (SEE SUPPL) 1310-73-2
7732-18-5
SOIDUM NITRITE (SEE SUPPL) 7632-00-0
7631-99-4
CFM 003, LITHIUM BROMIDE (SEE SUPPL) 7550-35-8
PERMA-SILK G (PPSG), (SEE SUPPL) 1317-33-5
12141-20-7
1309-64-4
78-93-3
1330-20-7
846 5080,CONCENTRATE,KODAK CINEFLURE H.S. DEVELOPER 7732-18-5
10117-38-1
123-31-9
111-46-6
7757-83-7
13047-13-7
HOMSA08,06, HOME SAFEGUARD, SMOKE DETECTOR TESTER, HOME SAFE 68476-86-8
G-6381, TELEDYNE BATTERY, GILL AIRCRAFT BATTERY (SEE SUPPL) 7439-92-1
7440-36-0
7440-38-2
7727-43-7
7440-70-2
1333-86-4
7440-31-5
LIGROINE, (SEE SUPPL.) 107-83-5
109-66-0
287-92-3
75-83-2
79-29-8
96-14-0
78-78-4
BATTERY ELECTROLYTE VARIOUS GRADES (SEE SUPPL) 7664-93-9
AMCO CLEAR TURBIDITY STANDARD (P/N: CRS-60-60)
812 1188,PT A,KODAK T-MAX 100 DIRECT POSITIVE FILM REVERSAL 7732-18-5
7722-64-7
812 1188,PT B,KODAK T-MAX 100 DIRECT POSITIVE FILM REVERSAL 7732-18-5
7664-93-9
ETHYLENE GLYCOL TECH 107-21-1
444, SPADNS REAGENT FOR FLUORIDE 7647-01-0
7784-46-5
7732-18-5
812 1188,WKG SOL,KODAK T-MAX 100 DIRECT POS FILM REV BLEACH 7664-93-9
7732-18-5
7722-64-7
812 1188,CONC,KODAK T-MAX 100 DIRECT POSITIVE(SEE SUPP DATA) 7732-18-5
10117-38-1
144-55-8
584-08-7
930-AA, LUBRIPLATE
ROYCO 560 67762-53-2
67762-52-1
68259-36-9
68411-46-1
1330-78-5
853931 IRON ALUMINUM ALLOY POWDER 7439-89-6
7429-90-5
ROYCO 560 67762-53-2
67762-52-1
68259-36-9
68411-46-1
1330-78-5
146 3470,KODAK SODIUM HYDROXIDE 1310-73-2
140 1124,KODAK SODIUM THIOSULFATE PENTAHYDRATE 10102-17-7
EAGLE SILICA GEL 7699-41-4
7732-18-5
TS1572, THAT GREEN STUFF 1303-96-4
68132-50-3
8002-09-3
67-63-0
8051-30-7
00683, TURCO 4460-BK 64742-89-8
108-88-3
141-78-6
108-10-1
67-63-0
IMPACT (SEE SUPPL) 7732-18-5
5989-27-5
8051-30-7
9016-45-9
E-59A CLEANER/REMOVER (SEE SUPPL) 64742-89-8
1024, SIFCO DALIC SOLUTION NO. 4 ETCHING AND ACTIVATING 7647-01-0
7732-18-5
MAGNAFLUX MAGNETIC PARTICLE 9C RED 1309-37-1
PO0011, HYSOL PC18M 108-65-6
1330-20-7
100-41-4
108-88-3
26471-62-5
LEAD-ACID BATTERY (ELECTRIC STORAGE BATTERY) 7439-92-1
7440-36-0
7440-31-5
7440-70-2
7440-38-2
7664-93-9
9003-07-0
809 0532,CONC,KODAK FLEXICOLOR STABILIZER AND REPLENISHER LF 7732-18-5
100-97-0
111-42-2
9003-39-8
57-55-6
9036-19-5
2634-33-5
809 0532,WKG SOL,KODAK FLEXICOLOR STABILIZER REPLENISHER LF 7732-18-5
100-97-0
111-42-2
29434-03-5
9003-39-8
2634-33-5
838 0578, PT A, KODAK FLEXICOLOR BLEACH III (SEE SUPPL) 7732-18-5
12124-97-9
631-61-8
64-19-7
838 0578, PT B, KODAK FLEXICOLOR BLEACH III (SEE SUPPL) 7732-18-5
111687-36-6
6484-52-2
64-19-7
1939-36-2
838 0578,WKG SOL,KODAK FLEXICOLOR BLEACH III REPLENISHER NR 7732-18-5
111687-36-6
631-61-8
12124-97-9
6484-52-2
64-19-7
124 9259,WKG SOL,KODAK RP X-OMAT DEVELOPER REPLENISHER 7732-18-5
10117-38-1
123-31-9
127-08-2
68310-08-7
111-30-8
7757-83-7
92-43-3
HOM 32000, SMOKE DETECTOR TESTER MODEL NO. 25 S, 2.5 OZ 74-98-6
75-28-5
106-97-8

Free MSDS Search ( Providing 250,000+ Material Properties )