Search   
MSDS  
:
 INSULATOR 9526054
CAS  
:
 12001-29-5
9003-35-4
NAME  
:
 asbestos, chrysotile
phenolic resin
=====================  Product Identification  =====================

MSDS NAME:INSULATOR 9526054
NIIN:00-567-8136
MSDS Number: BFFNV
=== Responsible Party ===
Company:GOODYEAR AEROSPACE CORP LORAL A/C BRAKING SYS
Address:1210 MASSILLON RD
City:AKRON
State:OH
ZIP:44315-0001
Info Phone Num:(216) 379-8562
Emergency Phone Num:(216) 379-8562
Preparer's Name:MARK S. HROSS
CAGE:EO533
=== Contractor Identification ===
Company:GOODYEAR AEROSPACE CORPORATION
Address:1210 MASSILLON ROAD
City:AKRON
State:OH
ZIP:44315
Phone:(216) 796-2121
CAGE:EO533
Company:LORAL CORP DEFENSE SYSTEMS DIV-AKRON
Address:1210 MASSILLON RD
Box:City:AKRON
State:OH
ZIP:44315-0001
Country:US
Phone:216-796-2800
CAGE:25500

=============  Composition/Information on Ingredients  =============

Name:ASBESTOS, CHRYSOTILE
CAS:12001-29-5
RTECS #:CI6478500
Fraction by Wt: 65-70%
OSHA PEL:0.2 FIBERS/CC
ACGIH TLV:2 FIBERS/CC; A1;9192

Name:PHENOLIC RESIN
CAS:9003-35-4
Fraction by Wt: 30-35%

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:NONE
Explanation of Carcinogenicity:CHRONIC OVEREXPOSURE TO ASBESTOS FIBERS
    MAY LEAD TO LUNG CANCER, ASBESTOSIS, AND MESOTHELIOMA.
Effects of Overexposure:INHALATION (OF DUSTS GENERATED BY MECHANICAL
    ABRASION) CHRONIC OVEREXPOSURE TO ASBESTOS FIBERS AMY LEAD TO LUNG
    CANCER, ASBESTOSIS, AND MESOTHELIOMA.
Medical Cond Aggravated by Exposure:LUNG DISEASE.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE TO FRESH AIR. OBTAIN MED. ADVICE.
    SKIN/EYE: WASH SOAP & WATER. IF IRRITATION OCCURS, SEE A PHYSICIAN.
    INGESTION: CONSULT A PHYSICIAN. OTHERS: CHANGE CLOTHING, IF
    NECESSARY, TO AVOID  CARRYING DUST PARTICLES INTO OTHER
    ENVIRONMENTS

=====================  Fire Fighting Measures  =====================

Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS.
    COMBUSTION PRODUCTS MAY BE TOXIC.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VACUUM OR WET CLEAN IF DUST IS INVOLVED. ANY
    VACUUM SYSTEM SHOULD BE EQUIPPED WITH AN OUTLET HEPA FILTER TO
    PREVENT REINTRODUCING ASBESTOS FIBERS TO THE ATMOSERE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:HANDLE TO MINIMIZE FORMATION OR
    RETENTION OF DUST.
Other Precautions:THE CHRYSOTILE ASBESTOS IS LOCKED IN A PHENOLIC RESIN
    AND DOESN'T PRESENT A HAZARD. ONLY WHEN THE RESIN SYSTEM IS ABRADED
    AND DUST IS GENERATED THAT ASBESTOS FIBERS BECOME RELEASED AND
    AIRBORNE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:A NIOSH/MSHA-APPROVED RESPIRATOR FOR ASBESTOS
    SHOULD BE USED.
Ventilation:LOCAL EXHAUST VENTILATION IS RECOMMENDED.
Eye Protection:SAFETY GOGGLES/FACE SHIEL
Work Hygienic Practices:MINIMIZE DUST GENERATION.
Supplemental Safety and Health
GOODYEAR AEROSPACE CORPORATION/AKRON, OHIO 44315-0001.

==================  Physical/Chemical Properties  ==================

Evaporation Rate & Reference:N/R/
Solubility in Water:0
Appearance and Odor:DARK BROWN SOLID
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES

====================  Disposal Considerations  ====================

Waste Disposal Methods:DUST SHOULD BE HANDLED AS A HAZARDOUS AIR
    POLLUTANT IN ACCORDANCE WITH 40 CFR 61 SUBPART M PERTAINING TO
    ASBESTOS. USE LANDFILLS APPROVED FOR ASBESTOS DISPOSAL. SCRAP PARTS
    AREN'T FRIABLE & AREN'T RES TRICTED UNDER AIR POLLUTION
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
MORPHOLINE CLASS III (O-M-575) 110-91-8
MORPHOLINE;PRODUCT CODE 55937 110-91-8
FA5351 1336-36-3
FA5352AND2FA5354 1336-36-3
OP440 1336-36-3
PR-148 78-93-3
67-63-0
141-78-6
PR-1750 CLASS B-2,PART A 1313-13-9
137-26-8
1333-86-4
14807-96-6
COOL-AMP (PRODUCT #1233-500) 7647-14-5
471-34-1
7783-90-6
BONDAID ETCHANT S16943 91-20-3
7440-23-5
673-0308-00 1336-36-3
673-0308-000 1336-36-3
26208 1336-36-3
ML-6544 7440-29-1
6544
AMMONIUM ACETATE 631-61-8
AMMONIUM ACETATE, CAT #3268 631-61-8
KKX37P255QAX303 1336-36-3
GAS GUARD #5616N 67-56-1
GAS LINE ANTIFREEZE 5613 (NEW#5616N)
FA2038 1336-36-3
28F1614FC 1336-36-3
21F138 1336-36-3
21F122 1336-36-3
SPRAY-CLEAN SOLVENT 67-66-3
64-17-5
8905K514
PR-1524 AMBER PART A 101-14-4
9009-54-5
PR-1524 AMBER,BLACK,PART B 6069-50-5
26471-62-5
FA1867 1336-36-3
CAT#200-903-1A,DESENSITIZER-DEVELOPER 7732-18-5
METER MAGNETIC
RED UTILITY BOXING WAX 8002-74-2
810 7440-29-1
810 7440-29-1
FA1621 1336-36-3
FA1767 1336-36-3
INSULATOR 9526054 12001-29-5
9003-35-4
MA3414
FA1273 1336-36-3
PLASTIKON 169 8006-61-9
CLUTCH MAGNETIC
28F830 1336-36-3
DOW CORNING 4 COMPOUND
STRONTIUM CHLORIDE HEXAHYDRATE;CAT. S541500 10025-70-4
SUPER X MECHANICAL VACUUM PUMP OIL, D250-76 64741-88-4
49F2277FB6 1336-36-3
195-6176 PROFESSIONAL FILM CEMENT 123-91-1
75-09-2
SUN TDF 99 9003-27-4
28F5155FC 1336-36-3
CM-34337,MSA CLEANER-SANITIZER 7601-54-9
497-19-8
13573-18-7
KN2040M0D 1336-36-3

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net