===================== Product Identification =====================
MSDS NAME:ZINC CHROMATE PRIMER,TT-P-1757,YELLOW
NIIN:00-582-5318
MSDS Number: BFGGJ
=== Responsible Party ===
Company:RANDOLPH PRODUCTS CO
Address:701 12TH STT
Box:830
City:CARLSTADT
State:NJ
ZIP:07072
Country:US
Info Phone Num:201-438-3700
Emergency Phone Num:201-438-3700
CAGE:77672
=== Contractor Identification ===
Company:RANDOLPH PRODUCTS CO
Address:701 12TH ST
Box:830
City:CARLSTADT
State:NJ
ZIP:07072-0830
Country:US
Phone:201-438-3700
CAGE:77672
============= Composition/Information on Ingredients =============
Name:ZINC CHROMATE
CAS:13530-65-9
RTECS #:GB3290000
Fraction by Wt: 34%
OSHA PEL:0.1 MG/M3 (CRO3)
ACGIH TLV:0.01MG/M3(CR)A1;9192
Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 21%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 19%
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:RESIN
Fraction by Wt: 25%
Name:ADDITIVES
Fraction by Wt: 1%
===================== Hazards Identification =====================
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF OVEREXPOSURE
SECTION .
Explanation of Carcinogenicity:CHROMATE(+6) IS A LISTED CARCINOGEN.
Effects of Overexposure:ACUTE:SOLVENT VAPORS MAY CAUSE DROWSINESS,
HEADACHE, DIZZINESS AND IRRITATION OF EYES, NOSE AND THROAT.
CHRONIC:N/K
Medical Cond Aggravated by Exposure:N/K
======================= First Aid Measures =======================
Eyes:FLUSH IMMED W/LGE AMTS OF WATER FOR AT LEAST 15 MIN,
CONSULT PHYSICIAN. INHALATION:REMOVE TO FRESH AIR. SUPPORT
BREATHING (GIVE O*2/ARTIFICIAL RESPIRATION)CONSULT PHYSICIAN.
INGESTION:CALL MD IM MEDIATELY .
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:45F/7.22C
Lower Limits:1.2
Upper Limits:N/K
Extinguishing Media:SAND, FOAM, CO*2, DRY CHEMICAL
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .AVOID BRTH VAPOR/FUME.COOL EXPOSED CONTAINERS
WITH WATER TO PREVENT EXPLOSION DUE TO PRESSURE.
Unusual Fire/Explosion Hazard:PREVENT FIRE, KEEP AWAY FROM HEAT,
SPARKS, AND OPEN FLAMES.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION,WEAR APPROVED
RESPIRATOR,CONTAIN SPILL WITH INERT SUBSTANCE (SAND,DIRT),PUT
MIXTURE IN CONTAINERS FOR DISPOSAL.KEEP SPILL OUT OF SEWERS AND
OPEN BODIES OF WATER.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT, FLAME.KEEP AWAY
FROM CHILDREN.GROUND CONTAINERS AND EQUIPMENT.EMPTY CONTAINERS ARE
HAZARDOUS, DO NOT CUT OR WELD
Other Precautions:N/K
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:EXPLOSION PROOF EXHAUST VENTILATION AT POINT OF CONTAMINANT
RELEASE.
Protective Gloves:NEOPRENE
Eye Protection:CHEM WORK GOGGLES
Other Protective Equipment:COVERALLS AND BOOTS
Work Hygienic Practices:N/K
Supplemental Safety and Health
BP:110-140C.PH:N.RT OF ENTRY:
================== Physical/Chemical Properties ==================
HCC:F2
Boiling Pt:B.P. Text:230-284F OR
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:N/K
Vapor Density:HV THN AIR
Spec Gravity:1.274
pH:N/K-FP
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:56
Corrosion Rate:N/K-FP-N
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDANTS.
Stability Condition to Avoid:FLAME OR HIGH HEAT
Hazardous Decomposition Products:CARBON MONOXIDE MAY FORM WHEN BURNED.
Conditions to Avoid Polymerization:FLAME OR HIGH HEAT
==================== Disposal Considerations ====================
Waste Disposal Methods:MANUFACTURER RECOMMENDS LANDFILL. DISPOSAL
METHODS MUST BE IAW FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|