Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: vectorlabs_com---msdssk4800.asp
           Vector Laboratories, Inc.                                                                Vector Laboratories, Inc.
30 Ingold Road 30 Ingold Road
Burlingame, CA 94010 Burlingame, CA 94010
VECTOR VECTOR
Tel: (650) 697-3600 Fax: (650) 697-0339 Tel: (650) 697-3600 Fax: (650) 697-0339

MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET
PAGE 1 PAGE 2
CHEMICAL IDENTIFICATION: CHEMICAL IDENTIFICATION (continued)
PRODUCT NAME Peroxidase Substrate Kit (Vector 庐 NovaRED 鈩?) PRODUCT NAME Peroxidase Substrate Kit (Vector庐 NovaRED 鈩?)
CATALOG NO. SK-4800 CATALOG NO. SK-4800

COMPOSITION/INFORMATION ON INGREDIENTS:
MATERIAL Reagent 1 contains a hazardous chemical whose identity STABILITY AND REACTIVITY:
is withheld as a trade secret. STABILITY Stable
% BY WEIGHT 10% MATERIALS TO AVOID n/a
HAZARDOUS POLYMERIZATION Will not occur
TOXICOLOGICAL INFORMATION: HAZARDOUS DECOMPOSITION PRODUCTS Carbon monoxide, carbon dioxide,
orl-rat LD50 : 21g/kg sulfur oxides.
orl-mus LD50 : 21g/kg
ivn-rbt LD50 : 19g/kg DISPOSAL CONSIDERATIONS:
ivn-mus LD50 : 16g/kg STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED Flush to
sewer if allowed or collect on absorbent and dispose in approved land fill.
TRANSPORT INFORMATION: WASTE DISPOSAL METHOD Flush to sewer if allowed.

EXPOSURE CONTROLS/PERSONAL PROTECTION:
PHYSICAL AND CHEMICAL PROPERTIES: RESPIRATORY PROTECTION Use NIOSH-MSHA approved respirator.
APPEARANCE Colorless liquid MELTING POINT n/a VENTILATION Use only with adequate ventilation.
SOLUBILITY IN WATER Soluble BOILING POINT n/a PROTECTIVE GLOVES NEEDED Yes
SPECIFIC GRAVITY n/a EVAPORATION RATE n/a EYE PROTECTION NEEDED Yes

FIRE FIGHTING MEASURES: HANDLING AND STORAGE:
FLASH POINT n/a FLAMMABLE LIMITS IN AIR n/a PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE Store in
EXTINGUISHING MEDIA Water, foam, carbon dioxide refrigerator.
SPECIAL FIREFIGHTING PROCEDURES USe respirator. Toxic gases can
be evolved: carbon monoxide, carbon dioxide, sulfur oxides. OTHER INFORMATION:
UNUSUAL FIRE AND EXPLOSION HAZARDS None The information contained in this Material Safety Data Sheet is believed to be accurate
but it is the responsibility of the user to determine the applicabilitY of these data to
HAZARDS IDENTIFICATION: the formulation of necessary safety precautions. Vector Laboratories Inc. shall not be
THRESHOLD LIMIT VALUE n/a held responsible for any damage resulting from the use of the above product or the
ACUTE EFFECTS OF OVEREXPOSURE May be harmful if placed on skin, information contained in this Material Safety Data Sheet.
in eyes, ingested or inhaled.
ECOLOGICAL INFORMATION:
FIRST AID MEASURES: Data not yet available.
EMERGENCY AND FIRST AID PROCEDURES Wash affected area thoroughly
with water. Irrigate eyes for at least 15 min. If inhaled, remove to fresh air. REGULATORY INFORMATION:
Call a physician immediately. For severe exposure, treat as cyanide poisoning.

ACCIDENTAL RELEASE MEASURES:
SKIN CONTACT May cause local discomfort
EYE CONTACT May be harmful
INHALATION May cause breathing difficulty
INGESTION Harmful if swallowed



CONTINUED ON NEXT PAGE CONTINUED ON NEXT PAGE
Vector Laboratories, Inc. Vector Laboratories, Inc.
30 Ingold Road 30 Ingold Road
Burlingame, CA 94010 Burlingame, CA 94010
VECTOR VECTOR
Tel: (650) 697-3600 Fax: (650) 697-0339 Tel: (650) 697-3600 Fax: (650) 697-0339

MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET
PAGE 3 PAGE 4
CHEMICAL IDENTIFICATION (continued) CHEMICAL IDENTIFICATION (continued)
PRODUCT NAME Peroxidase Substrate Kit (Vector庐 NovaRED 鈩?) PRODUCT NAME Peroxidase Substrate Kit (Vector庐 NovaRED 鈩?)
CATALOG NO. SK-4800 CATALOG NO. SK-4800

COMPOSITION/INFORMATION ON INGREDIENTS:
MATERIAL Acetonitrile (Reagents 2 and 3 are dissolved in acetonitrile) STABILITY AND REACTIVITY:
% BY WEIGHT 35% STABILITY Stable
MATERIALS TO AVOID Strong oxidizers acids or bases.
TOXICOLOGICAL INFORMATION: CONDITIONS TO AVOID Heat, sparks, open flame.
orl-rat LD50 : 3800mg/kg HAZARDOUS POLYMERIZATION Will not occur
skn-rbt LD50 : 1250mg/kg HAZARDOUS DECOMPOSITION PRODUCTS Carbon monoxide, carbon dioxide,
orl-gpg LD50 : 177mg/kg hydrogen cyanide.

TRANSPORT INFORMATION: DISPOSAL CONSIDERATIONS:
RTECS # AL770000M STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED Flush to
CAS # 75-05-08 sewer if allowed or collect on absorbent and dispose in approved land fill.
WASTE DISPOSAL METHOD Flush to sewer if allowed or dispose
PHYSICAL AND CHEMICAL PROPERTIES: according to federal, state, or local law.
APPEARANCE Colorless liquid MELTING POINT -44 deg C
SOLUBILITY IN WATER Soluble BOILING POINT 81.6 deg C EXPOSURE CONTROLS/PERSONAL PROTECTION:
SPECIFIC GRAVITY 0.78 EVAPORATION RATE 5 (Butyl Acetate = 1) RESPIRATORY PROTECTION Approved organic vapor respirator
VENTILATION Use only with adequate ventilation.
FIRE FIGHTING MEASURES: PROTECTIVE GLOVES NEEDED Yes
FLASH POINT 5.6 deg C FLAMMABLE LIMITS IN AIR 4.4 -16% EYE PROTECTION NEEDED Yes
EXTINGUISHING MEDIA Alcohol foam, carbon dioxide, dry chemical
SPECIAL FIREFIGHTING PROCEDURES Wear proper protective clothing and HANDLING AND STORAGE:
self contained breathing apparatus. PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE Store in
UNUSUAL FIRE AND EXPLOSION HAZARDS Very volatile flammable liquid. refrigerator.
Container could explode under fire conditions.
OTHER INFORMATION:
HAZARDS IDENTIFICATION: The information contained in this Material Safety Data Sheet is believed to be accurate
THRESHOLD LIMIT VALUE 40ppm (Air) but it is the responsibility of the user to determine the applicabilitY of these data to
ACUTE EFFECTS OF OVEREXPOSURE Headache, shallow respiration, the formulation of necessary safety precautions. Vector Laboratories Inc. shall not be
fatigue, nausea, convulsion, and death at high concentrations. held responsible for any damage resulting from the use of the above product or the
information contained in this Material Safety Data Sheet.
FIRST AID MEASURES:
EMERGENCY AND FIRST AID PROCEDURES Wash affected area thoroughly ECOLOGICAL INFORMATION:
with water. Irrigate eyes for at least 15 min. If inhaled, remove to fresh air. Data not yet available.
Call a physician immediately. For severe exposure, treat as cyanide poisoning.
REGULATORY INFORMATION:
ACCIDENTAL RELEASE MEASURES:
SKIN CONTACT May cause dermatitis
EYE CONTACT May cause irritation
INHALATION May cause headache convulsion, and/or death
INGESTION Harmful if swallowed



CONTINUED ON NEXT PAGE 漏 VECTOR LABORATORIES, INC. 2002

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
vectorlabs_com---msdsi5000.asp 26628-22-8
vectorlabs_com---msdsl1010.asp N/A
vectorlabs_com---msdsl1020.asp N/A
vectorlabs_com---msdsl1130.asp N/A
vectorlabs_com---msdsl1230.asp N/A
vectorlabs_com---msdsl1350.asp N/A
vectorlabs_com---msdslk2000.asp 9009-86-3 26628-22-8
vectorlabs_com---msdslk3000.asp N/A
vectorlabs_com---msdsmb1220.asp 26628-22-8
vectorlabs_com---msdsmb1230.asp N/A
vectorlabs_com---msdsmb1302.asp 26628-22-8 60-24-2
vectorlabs_com---msdsmb1920.asp 26628-22-8
vectorlabs_com---msdsmb2100.asp 26628-22-8
vectorlabs_com---msdsmb3100.asp 26628-22-8
vectorlabs_com---msdsmb9001.asp 77-86-1
vectorlabs_com---msdsmb9100.asp 26628-22-8
vectorlabs_com---msdsmkb2213.asp 26628-22-8
vectorlabs_com---msdsmp7405.asp 54-64-8
vectorlabs_com---msdsok3000series.asp 54-64-8
vectorlabs_com---msdspk2200.asp 54-64-8 26628-22-8
vectorlabs_com---msdss9003.asp 59-23-4
vectorlabs_com---msdss9004.asp 64044-51-5
vectorlabs_com---msdss9005.asp 617-04-9
vectorlabs_com---msdss9006.asp 97-30-3
vectorlabs_com---msdss9007.asp 2438-80-4
vectorlabs_com---msdssa1200.asp 26628-22-8
vectorlabs_com---msdssa5004.asp 54-64-8
vectorlabs_com---msdssa5008.asp 26628-22-8
vectorlabs_com---msdssa5010.asp 26628-22-8
vectorlabs_com---msdssa5100.asp 26628-22-8
vectorlabs_com---msdssk3100series.asp 67-56-1
vectorlabs_com---msdssk4100.asp 7411-49-6
vectorlabs_com---msdssk4105.asp 7411-49-6
vectorlabs_com---msdssk4200.asp 132-32-1
vectorlabs_com---msdssk4300.asp 604-44-4
vectorlabs_com---msdssk4500.asp 30931-67-0
vectorlabs_com---msdssk4600.asp 75-05-0
vectorlabs_com---msdssk4700.asp 75-05-0
vectorlabs_com---msdssk4800.asp N/A
vectorlabs_com---msdssk5100.asp 7791-18-6
vectorlabs_com---msdssk5200.asp 67-56-1
vectorlabs_com---msdssk5300.asp 67-56-1
vectorlabs_com---msdssk5400.asp 67-56-1
vectorlabs_com---msdssp0050.asp 26628-22-8
vectorlabs_com---msdssp0090.asp N/A
vectorlabs_com---msdssp0601.asp 26628-22-8
vectorlabs_com---msdssp1100.asp N/A
vectorlabs_com---msdssp1120.asp N/A
vectorlabs_com---msdssp1130.asp N/A
vectorlabs_com---msdssp1140.asp N/A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC