LOCTITE CORP -- PERMATEX FORM-A-GASKET NO 2 SEALANT, 2A
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BYHGF
MSDS NAME: PERMATEX FORM-A-GASKET NO 2 SEALANT, 2A
Responsible Party
Name: LOCTITE CORP
Address: 4450 CRANWOOD PKY
City: CLEVELAND OH 44128
Info Phone: 216-663-3011
Emergency Phone Number: 800-424-9300 (CHEMTREC)
Preparer's Name: JEAN TOBBE
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LOCTITE CORP
Address: 705 N MT RD
City: NEWINGTON CT 06111
Phone: 312-689-6200
Name: LOCTITE CORP AUTOMOTIVE AND CONSUMER GROUP
Address: 4450 CRANWOOD COURT
City: CLEVELAND OH 44128-4004
Phone: 216-663-3011
=======================================================
Ingredients
=======================================================
Cas: 1332-58-7
RTECS #: GF1670500
Name: CLAY (KAOLIN); (CLAY)
% Wt: 50-55
OSHA PEL: 10 MG/M3 (MFR)
ACGIH TLV: 2 MG/M3 (MFR)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE:VAPOR ABOVE TLV IS IRRITATING TO EYES, NOSE, THROAT
AND CAN CAUSE HEADACHE, DIZZINESS AND NAUSEA.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: SKIN, EYE, RESPIRATORY DISORDERS.
First Aid: INGEST:DO NOT INDUCE VOMITING AND GET MEDICAL ATTENTION.
INHAL:REMOVE TO FRESH AIR. CALL PHYSICIAN. SKIN:WASH WITH LARGE QUANTITIES OF
SOAP AND WATER. EYE:FLUSH WITH WATER FOR @ LEAST 15 MINUTES AND C ONSULT
PHYSICIAN.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: REMOVE SOURCES OF IGNITION, MAINTAIN ADEQUATE
VENTILATION. SCRAPE UP AS MUCH AS POSSIBLE AND STORE IN A CLOSED CONTAINER
UNTIL DISPOSAL RESIDUES MAY BE CLEANED WITH ISOPROPYL ALCOHOL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: INCINERATE EPA AND LOCAL REGULATIONS. RCRA HAZARDOUS
WASTE NO:3001. DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS
(FP N).
Handling And Storage Precautions: DO NOT STORE NEAR HEAT, SPARKS OR FLAME.
Other Precautions: AVOID PROLONGED BREATHING OF VAPORS AND CONTACT WITH EYES.
AVOID PROLONGED SKIN CONTACT.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point Text: 60.0F,15.6C
Lower Limits: 2.0%
Upper Limits: 12.0%
Extinguishing Media: CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FP N).
Ventilation: SUFFICIENT TO MAINTAIN VAPOR CONCENTRATION BELOW TLV.
Protective Gloves: RUBBER OR PLASTIC GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPRVD EMERGENCY EYE WASH & DELUGE SHOWER (FP
N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 180F,82C
Vapor Pres: 33 @ 68F
Vapor Density: 2.07
Spec Gravity: 1.5 @ 77F
Evaporation Rate & Reference: 7.7 (ETHER =1)
Solubility in Water: PARTIAL
Appearance and Odor: BLACK PASTE, ALCOHOLIC ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG OXIDIZERS.
Hazardous Decomposition Products: (NON-THERMAL):NONE KNOWN.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PERMATEX FORM-A-GASKET NO 2 SEALANT, 2A
Company: LOCTITE CORP
Street: 705 N MT RD
City: NEWINGTON CT
Zipcode: 06111
Health Emergency Phone: 800-424-9300 (CHEMTREC)
Label Required IND: Y
Date Of Label Review: 07/13/1995
Status Code: C
Label Date: 07/13/1995
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Slight
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: EXTREMELY FLAMMABLE. ACUTE:VAPOR ABOVE TLV IS
IRRITATING TO EYES, NOSE, THROAT AND CAN CAUSE HEADACHE, DIZZINESS AND
NAUSEA. CHRONIC:NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|