TRACE SYSTEMS INC -- MARK-IT
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CBCFJ
MSDS NAME: MARK-IT
Responsible Party
Name: TRACE SYSTEMS INC
Address: 9330 CORP DR 801
City: SCHERTZ TX 78154
Info Phone: 210-651-9651
Emergency Phone Number: 210-655-4594
Preparer's Name: JEAN ZYCH
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: TRACE SYSTEMS INC
Address: 9330 CORPORATE DR #801
City: SCHERTZ TX 78154
Phone: 512-651-9651
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: YES
IARC: YES
OSHA: YES
Effects of Exposure: LIGHTHEADEDNESS, GIDDINESS, SHORTNESS OF BREATH, POSSIBLE
NARCOSIIS AT HIGH CONCENTRATIONS. CHLOROFLUOROCARBON (CFC) MATERIALS HAVE
PRODUCED SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LABORATOR Y
ANIMALS & COULD HAVE A SIMILAR EFFECTIN HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRA- (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: IARC GROUP 2A, SUP 7, P.139, 1987; ANTICIPATED
CARCINOGEN, NTP 7TH ANNUAL REPORT, 1994; OSHA REG 29 CFR 1910.1027.
Signs And Symptions Of Overexposure: HLTH HAZ:INDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CFC'S (FP
N).
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHAL:REMOVE TO FRESH AIR. CALL MD. DO NOT GIVE EPINEPHRINE OR
SIMILAR DRUGS (ADRENALINES). EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES; SEE
MD IF SYMPTOMS CONTINUE. SKIN:WASH WELL W/SOAP & WATER. INGE ST:DO NOT
INDUCE VOMITING. CALL MD IMMEDIATELY. REPORT INGESTION OF PRODUCT BY CHEMICAL
NAME & FAMILY. IN CASE OF SEVERE EMERGENCY, CALL TRACE SYSTEMS FOR
SPECIFIC TRACE ELEMENTS.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: MOP UP & REMOVE TO OUTSIDE. VENTILATE AREA -
ESPECIALLY LOW POINTS. REMOVE OPEN FLAMES.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL TO BE I/A/W LOCAL, STATE & FEDERAL
REGULATIONS.
Handling And Storage Precautions: STORE IN CLEAN, DRY AREA. DO NOT HEAT ABOVE
125. DO NOT INGEST.
Other Precautions: NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR PHOSGENE (FP N).
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: CC
Flash Point Text: NONE
Lower Limits: NONE
Upper Limits: NONE
Extinguishing Media: FOAM, CO*2, WATER SPRAY, DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE
FLUORIDES, CHLORIDES & PHOSGENE (FP N). EXPOSURE TO HEAT BUILDS UP
PRESSURE IN CONTAINERS. COOL W/WATER STREAM.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED AIR MASK IN VERY HIGH
CONCENTRATIONS.
Ventilation: LOCAL EXHAUST IF LARGE AMOUNT OF VAPOR PRESENT: MECHANICAL EXHAUST
IN LOW AREAS.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 117F,47C
Vapor Pres: 330
Vapor Density: 2.9
Spec Gravity: 1.5 (H*2O=1)
Solubility in Water: 0.02% BY WT
Appearance and Odor: CLEAR TO DARK AMBER LIQUID; MINERAL SPIRITS ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: OPEN FLAMES OR HIGH TEMPERATURES.
Materials To Avoid: STRONG ACIDS, OXIDIZING MATERIALS, ALKALAI OR ALKALINE
EARTH METALS.
Hazardous Decomposition Products: CHLORIDES & FLUORIDES (FP N). HYDROFLUORIC &
HYDROCHLORIC ACIDS; POSSIBLE PHOSGENES.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: MARK-IT
Company: TRACE SYSTEMS INC
Street: 9330 CORPORATE DR #801
City: SCHERTZ TX
Zipcode: 78154
Health Emergency Phone: 210-655-4594
Label Required IND: Y
Date Of Label Review: 05/15/1996
Status Code: C
Label Date: 05/15/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: DECOMPOSITION PRODUCTS MAY BE HARMFUL. ACUTE:INHALATION
OF VAPORS MAY CONTRIBUTE TO THE OCCURRENCE OF IRREGULAR HEARTBEAT (FP N).
LIGHTHEADEDNESS, GIDDINESS, SHORTNESS OF BREATH, POSSIBLE NARCOSIIS AT HIGH
CONCENTRATIONS. CHRONIC: CANCER HAZARD: MAY CONTAIN MATERIAL REGULATED AS A
RESPIRATORY TRACT CARCINOGEN (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.