Search   
MSDS  : AEON 800, 28G8
CAS  :
NAME  : *** proprietary ***
GARDNER DENVER MACHINERY INC -- AEON 800, 28G8
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CBHLT
MSDS NAME: AEON 800, 28G8
Responsible Party
Name: GARDNER DENVER MACHINERY INC
Address: 1800 GARDNER EXPRESSWAY
City: QUINCY IL 62301
Info Phone: 217-222-5400
Emergency Phone Number: 217-222-5400;800-424-9300(CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: GARDNER DENVER MACHINERY INC
Address: 1800 GARDNER EXPRESSWAY
City: QUINCY IL 62301
Phone: 217-222-5400
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50(ORAL,RAT):>5 G/KG
Route Of Entry Inds - Inhalation: NO
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: SLIGHT EYE & SKIN IRRIT. TOX DATA:BASED ON TESTING OF
SIMILAR PRODS &/OR COMPONENTS: ACUTE:INGEST (RATS) & SKIN
(RABBITS):SLIGHTLY TOX (ESTIMATED). INHAL (RATS):HARMFUL CONCS OF MISTS
&/OR VAPS ARE UN LIKELY TO BE ENCOUNTERED THRU ANY CUSTOMARY/REASONABLY
FORESEEABLE HNDLG, USE/MISUSE. EYE (RABBITS):(EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZS:MAY CAUSE SLIGHT IRRIT. SKIN
(RABBITS:)MAY CAUSE SLIGHT IRRIT ON PRLNGD/RPTD CONT. SUBCHRONIC TOX:SEVERLY
SOLV REFINED & SEVERELY HYDROTREATED MINERAL BASE OILS HAVE BEEN TESTED
AT ENVIRON & HLTH SCIENCES LAB BY DERMAL APPLICATN TO RATS 5 DAYS/WEEK
FOR 90 DAYS @ DOSES SIGNIFICANTLY HIGHER THAN THOSE (SUP DAT)
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP)
(FP N). EYES:FLUSH W/WATER FOR AT LST 15 MIN. SKIN:WASH CONT AREAS W/SOAP
& WATER. INGEST:NOT EXPECTED TO BE PROBLEM. HOWEVER, IF >1/2 LITER
(PINT) INGESTED, IMMED GIVE 1-2 GLASSES OF WATER & CALL MD, HOSPITAL EMER
ROOM/POIS CTL CTR FOR ASSISTANCE. DO NOT INDUCE VOMITING OR GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: RPT SPILLS AS REQ TO APPROP AUTHS. U.S. COAST GUARD
REGS REQ IMMED REPORTING OF SPILLS THAT COULD REACH ANY WATERWAY INCLUDING
INTERMITTENT DRY CREEKS. RPT SPILL TO COAST GUARD TOLL FREE # 800-424-880 2.
IN CASE OF ACCIDENT/ROAD SPILL NOTIFY
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISP MUST BE I/A/W FED, STATE & LOC REGS (FP N).
PROD IS SUITABLE FOR BURNING IN ENCLSD, CONTROLLED BURNER FOR FUEL
VALVUE/DISP BY SUPERVISED INCIN. SUCH BURNING MAY BE LTD PURSUANT TO RCRA. IN
ADDN, PROD IS SUITABLE FOR PROCESSING BY APPRVD
Handling And Storage Precautions: NO SPECIAL PRECAUTIONS REQUIRED.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: COC
Flash Point Text: >350F,>177C
Lower Limits: 0.6%
Upper Limits: 7.0%
Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICAL AND WATER FOG.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). PVNT RUNOFF FROM FIRE CTL/DILUTION FROM ENTERING STREAMS/DRINKING WATER
SUPPLY. WATER/FOAM MAY (SUPP DATA)
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N). NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS
OF USE AND WITH ADEQUATE VENTILATION.
Ventilation: NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS OF USE AND WITH
ADEQUATE VENTILATION.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: ANSI APPROVED EMERGENCY EYE WASH AND DELUGE SHOWER
(FP N).
Work Hygienic Practices: PERSONAL HYGIENE PRACTICES SHOULD ALWAYS BE FOLLOWED.
Supplemental Safety and Health: USERS OF "L" VERSION CONSULT "LR" VERSION FOR
ADDNL INFO (FP N). FIRE FIGHT PROC:CAUSE FROTHING. USE WATER TO KEEP FIRE
EXPOSED CNTNRS COOL. WATER SPRAY MAY BE USED TO FLUSH SPILLS AWAY FROM EXPOS.
EF TS OF OVEREXP:EXPECTED DURING NORMAL INDUST EXPOS. EXTENSIVE EVALS,
INCLUDING MICROSCOPIC EXAM OF INTERNAL
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >600F,>316C
Vapor Pres: <0.1
Spec Gravity: 0.875
Solubility in Water: NEGLIGIBLE
Appearance and Odor: RED LIQUID WITH A MILD ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: EXTREME HEAT.
Materials To Avoid: STRONG OXIDIZERS.
Hazardous Decomposition Products: CARBON MONOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: AEON 800, 28G8
Company: GARDNER DENVER MACHINERY INC
Street: 1800 GARDNER EXPRESSWAY
City: QUINCY IL
Zipcode: 62301
Health Emergency Phone: 217-222-5400;800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 01/09/1996
Status Code: C
Label Date: 01/09/1996
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: CAUTION. COMBUSTIBLE. ACUTE:SLIGHT EYE AND SKIN
IRRITATION. CHRONIC:NONE SPECIFIED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
DRY POWDERED TONER - SX 25153-46-2
1317-61-9
84179-66-8
25322-69-4
68611-44-9
ACT II 200 14807-96-6
16389-88-1
1318-59-8
13397-26-7
546-93-0
14808-60-7
163 PRIMER/SEALER II INTERIOR 7664-41-7
50-00-0
1897-45-6
G22N
SONOPLEX 200 ACTIVATOR, 06-102B
NOCHROMIX (CRYSTAL), 0041806
POLY ENAMEL SLOW THINNER SOLVENT, PE-182 68333-88-0
DUSQUEEZE, 01866 138-86-3
9016-45-9
7732-18-5
64-02-8
27323-41-7
METEX SOLDER REMOVER 9295, 19295
CAX-100-T THINNER
WETTING AGENT 9036-19-5
7732-18-5
379B9500/2904, DEVTHANE 379 HIGH SOLIDS (SUP DAT) 29354-73-2
7727-43-7
110-43-0
123-86-4
75-56-9
13463-67-7
1330-20-7
CORTEC 423 GEL
OLEORESIN RED PEPPER 1,500,000 AHU, 608229
GRANULAR FERTILIZER 57-13-6
9011-05-6
7783-28-0
7447-40-7
7778-80-5
7782-63-0
7487-88-9
7785-87-7
1309-37-1
1317-35-7
14977-37-8
471-34-1
39409-82-0
7704-34-9
PRE-M 3.3 EC HERBICIDE 40487-42-1
64742-94-5
COPPER SULFATE, 14818 7758-99-8
POTASSIUM CYANIDE 151-50-8
ROZOL BLUE TRACKING POWDER 3691-35-8
DUREZ 23570 PHENOLIC NOVOLAC THERMOSETTING (SUPDAT)
POLAR CHIP 347L IONIC COOLANT 111-42-2
102-71-6
SECURLINE MARKER II, 1451 (BLACK)
SECURLINE MARKER II, 1456 (RED)
GRAM STAIN PEN, 1486 (RED)
GS-1
GS-2
GS-3
GS-4
GS-4-P
GS-101
QTR PREMIUM PLUS 4, 44-440-1
QTR PREMIUM PLUS 4, 44-20-2
AEON 800, 28G7
AEON 800, 28G8
HYDRANAL COMPOSITE 1-34827 111-77-3
288-32-4
7446-09-5
7553-56-2
10034-85-2
EP CARTRIDGE, 310924-5XX
ECHONOX
W-763 WALL MORTAR ALL COLORS, 63501
EBECRYL 3700, 022L001 55818-57-0
123-31-9
TRPGDA, 022L201 42978-66-5
TMPTA, 022L203 15625-89-5
700 INDUSTRIAL GRADE SILICONE SEALANT-WHITE 4253-34-3
112945-52-5
17689-77-9
70131-67-8
63148-62-9
GOLD BOND POLYSULIFIDE SEALANT, X-854Z 68611-50-7
1317-65-3
7440-44-0
1309-60-0
85-68-7
DOWFLAKE 77-80% CALCIUM CHLORIDE (FIBC), 18611 10043-52-4
7647-14-5
7447-40-7
7732-18-5
BELOW GROUND WOOD PRESERVATION, 50916
PH 4.01 BUFFER SOLUTION, HI 7004 877-24-7
7732-18-5
121-54-0
PH 7.01 BUFFER SOLUTION, HI 7007 7778-77-0
7558-79-4
121-54-0
7732-18-5
PH 10.01 BUFFER SOLUTION, HI 7010 144-55-8
497-19-8
121-54-0
7732-18-5
AIRSEAL 33
FOMREZ UL-28 CATALYST, 734-4634

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net