ITW DEVCON -- ALUMINUM CASTING HARDENER (F-3), 11725
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CBMWH
MSDS NAME: ALUMINUM CASTING HARDENER (F-3), 11725
Kit Part: Y
Responsible Party
Name: ITW DEVCON
Address: 30 ENDICOTT ST
City: DANVERS MA 01923
Info Phone: 508-777-1100
Emergency Phone Number: 800-424-9300 (CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DEVCON CORP
Address: 30 ENDICOTT ST
City: DANVERS MA 01923-3753
Phone: 1-508-777-1100
Name: ITW DEVCON
Address: 30 ENDICOTT ST
City: DANVERS MA 01923-3712
Phone: 978-777-1100
=======================================================
Ingredients
=======================================================
Cas: 112-24-3
RTECS #: YE6650000
Name: TRIETHYLENETETRAMINE; (TETA) LD50: (ORAL, RAT) 2500 MG/KG
% Wt: 5-10
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 69980-74-1
Name: PROPOXYLATED DIETHYLENETRIAMINE & TRIETHYLENETRIAMINE; (PROPOXYLATED
POLYAMINES)
% Wt: 30-60
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 112-57-2
RTECS #: KH8585000
Name: 1,2-ETHANEDIAMINE,N-(2-AMINOETHYL)-N'-(2- ((2-AMINOETHYL)AMINO)ETHYL);
(TETRAETHYLENEPENTAMINE (TEPA))
% Wt: 5-10
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 68155-17-9
Name: TALL OIL FATTY ACID ADDUCT OF TEPA; (TALL OIL FATTY ACID AMIDO AMINE
ADDUCT OF TEPA)
% Wt: 30-60
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
RTECS #: 9999999VO
Name: VOLATILE ORGANIC COMPOUND: 0 LBS/GAL (EPA REFERENCE METHOD 24)
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGREDIENT 1
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: EYES: SEVERE IRRITATION OR BURNS. SKIN: SEVERE
IRRITATION OR BURNS, POSSIBLE ALLERGIC RESPONSE. INHALATION: RESPIRATORY
IRRITATION; POSSIBLE ALLERGIC RESPONSE. INGESTION: NO DATA. CHRONIC: PROL
ONGED OR REPEATED OVEREXPOSURE TO POLYAMINES CAN CAUSE SKIN OR RESPIRATORY
SENSITIZATION WITH ITCHING, (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ: SWELLING, RASHES AND/OR
ASTHMA-LIKE RESPIRATORY REACTION ON LATER EXPOSURE. REPEATED OVEREXPOSURE TO
POLYAMINES IS REPORTED TO CAUSE LIVER AND KIDNEY DAMAGE.
Medical Cond Aggravated By Exposure: ALLERGY, ECZEMA, SKIN CONDITION.
First Aid: EYES: IMMEDIATE AND CONTINUOUS IRRIGATION WITH FLOWING WATER FOR AT
LEAST 30 MINUTES IS IMPERATIVE. SKIN: IMMEDIATELY REMOVE ANY CONTAMINATED
CLOTHING AND WASH THOROUGHLY WITH SOAP AND WARM WATER. INH AL: REMOVE TO
FRESH AIR. CONTACT MD IF SYMPTOMS PERSIST. INGEST: CORROSIVE. DO NOT INDUCE
VOMITING. GIVE LARGE AMOUNTS OF WATER OR MILK IF AVAILABLE AND TRANSPORT TO
MEDICAL FACILITY.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: PREVENT SKIN AND EYE CONTACT. REMOVE CONTAMINATED
CLOTHING. DISCARD CONTAMINATED LEATHER ARTICLES SUCH AS SHOES AND BELTS.
ABSORB SPILLAGE ON INERT MATERIAL AND DISCARD IN SUITABLE CONTAINERS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: REMOVE TO A WASTE DISPOSAL FACILITY OPERATING IN
COMPLIANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.
Handling And Storage Precautions: KEEP HANDS AWAY FROM EYES WHEN HANDLING
MATERIAL OR BEFORE WASHING AFTER USE. STORE IN A COOL, DRY PLACE.
Other Precautions: PRLNGD/RPTD OVEREXP MAY CAUSE SENSIT & ALLERGIC
RESPONSE. PERS SO AFFECTED SHOULD CONSULT MD. IF SENSIT IS CONFIRMED, AVOID
FURTHER EXPOS TO MATL. PROD INFO APPLIES TO HARDENER COMPONENT OF TWO-PART K
IT. AFTER PROPER MIXING WITH (SUPDAT)
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: >200F,>93C
Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N). DILUTION WITH LARGE AMOUNTS OF WATER REDUCES INTENSITY OF
FLAME.
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NO RESPIRATORY PROTECTION NEEDED IN NORMAL USE WITH
PROPER VENTILATION. IN POORLY VENTILATED AREAS WEAR NIOSH/MSHA APPROVED
ORGANIC VAPOR MASK.
Ventilation: LOCAL EXHAUST IS RECOMMENDED FOR PRLNGD OR RPTD USE. EFFECTIVE
MECHANICAL VENTILATION IS ADEQUATE FOR OCCASIONAL USE.
Protective Gloves: CHEM RESISTANT RUBBER GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS (SUPDAT)
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N).
OTHER PROTECTIVE GEAR AS REQUIRED TO PREVENT SKIN CONTACT.
Work Hygienic Practices: WASH THOROUGHLY AFTER USING, PARTICULARLY BEFORE
EATING OR SMOKING.
Supplemental Safety and Health: PH (5% BY WEIGHT IN WATER): 10-11. OTHER PRECS:
RESIN & CURING, PRODUCT FORMS A NONHAZARDOUS SOLID. EYE PROT: & FULL
LENGTH FACESHIELD (FP N).
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Pres: 1 @ 68F
Vapor Density: >1
Spec Gravity: 0.96
PH: SUPDAT
Solubility in Water: APPRECIABLE
Appearance and Odor: AMBER LIQUID WITH AMMONIA-LIKE ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: EXPOS TO OPEN FLAME/EXCESSIVE HEAT. HEAT IS RELSD
WHEN PROD MIXED W/EPOXY HARDENERS; USE CAUTION WHEN MIXING LG QTYS.
Materials To Avoid: STRONG OXIDIZING AGENTS, ACIDS AND CHLORINATED ORGANIC
COMPOUNDS.
Hazardous Decomposition Products: OXIDES OF NITROGEN, CARBON AND AMMONIA.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: ALUMINUM CASTING HARDENER (F-3), 11725
Company: ITW DEVCON
Street: 30 ENDICOTT ST
City: DANVERS MA
Zipcode: 01923-3712
Health Emergency Phone: 800-424-9300 (CHEMTREC)
Label Required IND: Y
Date Of Label Review: 06/12/1996
Status Code: C
Label Date: 06/12/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Severe
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: CAUSTIC ALKALI LIQUID. ACUTE: EYES: SEVERE IRRITATION
OR BURNS. SKIN: SEVERE IRRITATION OR BURNS, POSSIBLE ALLERGIC RESPONSE.
INHALATION: RESPIRATORY IRRITATION; POSSIBLE ALLERGIC RESPONSE. CHRONIC: P
ROLONGED OR REPEATED OVEREXPOSURE TO POLYAMINES CAN CAUSE SKIN OR RESPIRATORY
SENSITIZATION WITH ITCHING, SWELLING, RASHES AND/OR AN ASTHMA-LIKE
RESPIRATORY REACTION ON LATER EXPOSURE. REPEATED OVEREX POSURE TO POLYAMINES
IS REPORTED TO CAUSE LIVER AND KIDNEY DAMAGE.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.