Search   
MSDS  : ENERGINE SPOT REMOVER, 01-00385-000
CAS  : 64742-89-8
NAME  : vm & p naphtha; (naphtha (petroleum), light aliphatic)
L&F PRODUCTS -- ENERGINE SPOT REMOVER, 01-00385-000
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CBMPC
MSDS NAME: ENERGINE SPOT REMOVER, 01-00385-000
Responsible Party
Name: L&F PRODUCTS
Address: 225 SUMMIT AVE
City: MONTVALE NJ 07645
Info Phone: 201-573-5700
Emergency Phone Number: 800-424-9300(CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: L&F PRODUCTS
Address: 225 SUMMIT AVE
City: MONTVALE NJ 07645
Phone: 201-573-5700
Name: RECKITT & COLMAN INC
Address: 225 SUMMIT AVE
City: MONTVALE NJ 07645
Phone: 201-573-5700
=======================================================
Ingredients
=======================================================
Cas: 64742-89-8
Name: VM & P NAPHTHA; (NAPHTHA (PETROLEUM), LIGHT ALIPHATIC)
% Wt: 100
OSHA PEL: 300 PPM (MFR)
ACGIH TLV: 300 PPM (MFR)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: INHALATION:USE ONLY W/GOOD VENTILATION - PROVIDE CONSTANT
FLOW OF FRESH AIR. AVOID REPEATED OR PROLONGED BREATHING OF VAPOR.
INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING & INHALING CONTENTS MAY
BE HARMFUL OR FATAL. SKIN/EYES:AVOID CONTACT. INGESTION:HARMFUL OR FATAL IF
SWALLOWED. REPEATED OR (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:PROLONGED OVEREXPOSURE TO NAPHTHA
HAS BEEN ASSOCIATED W/NEUROLOGICAL DAMAGE.
Medical Cond Aggravated By Exposure: PRE-EXISTING RESPIRATORY DISORDERS.
First Aid: INHAL:MOVE USER TO FRESH AIR & MAINTAIN RESP. CALL POIS CTR/MD
IMMED. SKIN:REMOVE CONTAM CLTHG & FLUSH SKIN W/PLENTY OF SOAP &
WATER. EYES:IMMED FLUSH W/WATER, REMOVE ANY CONTACT LENSES & CONTINUE TO
FLUSH W/PLENTY OF WATER FOR AT LST 15 MINS. INGEST:DO NOT INDUCE VOMIT. CALL
MD/POIS CTL CTR IMMED. NOTE TO MD:THIS PROD CONTAINS PETROLEUM DISTILLATES. A
SEVERE LUNG ASPIRATION HAZARD EXISTS.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: DANGER! FLAMM LIQ & VAP. KEEP AWAY FROM HEAT,
SPK, OPEN FLAME, ELEC MOTORS & OUTLETS, PILOT LIGHTS, LIGHTED
CIGARETTES/OTHER IGNIT SOURCES DURING USE & UNTIL ALL VAPS ARE GONE. TAKE
UP SPILLS W/ABSORB MATL & PLACE IN NON-LEAKING CNTNRS. SEAL (SUPDAT)
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
REGULATIONS.
Handling And Storage Precautions: DANGER! FLAMMABLE LIQUID & VAPOR.
HARMFUL/FATAL IF SWALLOWED. MAY CAUSE EYE & SKIN IRRITATION. CONTAINS
100% NAPHTHA.
Other Precautions: DO NOT STORE OR USE NEAR HEAT, SPARKS OR FLAME. VAPORS MAY
CAUSE FLASH FIRE. AVOID RPTD/PRLNG BRTHG OF VAPS. AVOID CONTACT W/EYES OR
SKIN. CLOSE CNTNR TIGHTLY AFTER EACH USE & STORE ONLY W/CNTNR CLSD. KEEP
OUT OF REACH OF CHILDREN.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point Text: 55.0F,12.8C
Lower Limits: 1%
Upper Limits: 7%
Extinguishing Media: USE WATER FOG, FOAM, DRY CHEM/CO*2. DO NOT USE DIRECT
STREAM OF WATER. PROD WILL FLOAT & CAN BE REIGNITED ON (SUPP DATA)
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: CNTNRS EXPOS TO INTENSE HEAT FROM FIRES SHOULD
BE COOLED W/WATER TO PVNT VAP PRESS BUILDUP WHICH COULD RSLT IN CNTNR
RUPTURE. CNTNR AREAS EXPOS TO (SUPP DATA)
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FP N). NONE REQUIRED.
Ventilation: USE ONLY W/GOOD VENTILATION - PROVIDE CONSTANT FLOW OF FRESH AIR.
Protective Gloves: IMPERMEABLE GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N). EMER RESPONDERS SHOULD WEAR PROT CLTHGS.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: EXTING MEDIA:SURF OF WATER. EXPLO HAZ:DIRECT
FLAME CONT SHOULD BE COOLED W/LG QTYS OF WATER AS NEEDED TO PVNT WEAKENING OF
CNTNR STRUCTURE. VAPS MAY CAUSE FLASH FIRE. CNDTNS(STAB):SOURCES DURING USE.
SPILL PROC:TIGHTLY FOR PROPER DISPOSAL.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >247F,>119C
Vapor Pres: 25 @ 100F
Vapor Density: 3.8
Spec Gravity: 0.75
Solubility in Water: NEGLIGIBLE
Appearance and Odor: LIGHT COLOR LIQUID; HYDROCARBON ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: KEEP AWAY FROM HEAT, SPARK, OPEN FLAME, ELEC
MOTORS & OUTLETS, PILOT LIGHTS, LIGHTED CIGARETTES/OTHER IGNIT (SUPP DATA)
Materials To Avoid: STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products: CARBON MONOXIDE, CARBON DIOXIDE &
UNIDENTIFIED ORGANIC COMPOUNDS.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: ENERGINE SPOT REMOVER, 01-00385-000
Assigned IND: Y
Company: L&F PRODUCTS
Street: 225 SUMMIT AVE
City: MONTVALE NJ
Zipcode: 07645
Health Emergency Phone: 800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 05/23/1996
Status Code: C
Label Date: 05/23/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: FLAMMABLE. ACUTE:INHALATION:INTENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING AND INHALING CONTENTS MAY BE HARMFUL OR FATAL.
SKIN OR EYES:AVOID CONTACT. INGESTION:HARMFUL OR FATAL IF SWALLOWED. CHRONIC
:REPEATED OR PROLONGED OVEREXPOSURE TO NAPHTHA HAS BEEN ASSOCIATED WITH
NEUROLOGICAL DAMAGE.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
ENERGINE SPOT REMOVER, 01-00385-000 64742-89-8
MEDIUM FLOW LACQUER THINNER, 309-013 64742-89-8
108-88-3
67-63-0
67-64-1
123-86-4
1330-20-7
110-43-0
111-76-2
NEW & IMPROVED SPRAY MATE MULTI ALKALINE (SUP DAT)
DC LS POLYAMIDE EPOXY - TINTABLE WHITE A, BEXG164 64742-95-6
2807-30-9
1330-20-7
KYOCERA F-1800 TONER
DB-X100
ALUMINUM CASTING RESIN (F-3), 11725 25068-38-6
84-74-2
ALUMINUM CASTING HARDENER (F-3), 11725 112-24-3
69980-74-1
112-57-2
68155-17-9
INSL TRON S/G NEUTRAL BASE, BAU0399 1330-20-7
763-69-9
108-65-6
108-88-3
MASONRY CEMENTS 12168-85-3
10034-77-2
12042-78-3
12068-35-8
13397-24-5
1305-78-8
1309-48-4
7757-82-6
WHITE MASONRY CEMENTS 12168-85-3
10034-77-2
12042-78-3
12068-35-8
13397-24-5
1305-78-8
1309-48-4
7757-82-6
CUSTOM COLOR MASONRY CEMENTS 12168-85-3
10034-77-2
12042-78-3
12068-35-8
13397-24-5
1305-78-8
1309-48-4
7757-82-6
3044 ADHESIVE
SUSPEND, 04903 7320-34-5
7732-18-5
2235-43-0
9003-04-7
KILFROST TOOL OIL 107-21-1
102-71-6
64741-53-3
REAL WOOD FILLER-LWF 67-64-1
123-86-4
108-88-3
67-63-0
2942 CIA DEGREASER 111-76-2
1310-58-3
224 INTERIOR ACRYLIC SG 24091, B224AC
ST2070, PART A, STP SUPER CONCENTRATE INTAKE(SUPDAT)
ST2070, PART B, STP SUPER CONCENTRATE INTAKE(SUPDAT)
ST2070 CAN, PART A, STP SUPER CONCENTRATE (SUPDAT)
ST2070 CAN, PART B, STP SUPER CONCENTRATE (SUPDAT)
9557X, PART A, STP SUPER CONCENTRATE (SUPDAT)
9557X, PART B, STP SUPER CONCENTRATE (SUPDAT)
FT DEVELOPER TYPE 310-BLACK, 888268
4604
MILD STEEL ELECTRODE 5/23, 20503000 7439-89-6
1317-65-3
13463-67-7
1344-28-1
MILD STEEL ELECTRODE 1/8, 20504000 7439-89-6
1317-65-3
13463-67-7
1344-28-1
LE-5000, 77138
71500
71502
FREKOTE 1 DRY LUBRICANT (AEROSOL), FK0100
59628, DE-VO-LAC SUPER BUILD LACQUER CLEAR (SUPDAT) 64742-89-8
1330-20-7
108-88-3
67-63-0
108-10-1
78-93-3
85-68-7
110-19-0
DEVTHANE 359 H D WHITE BASE, 359B3501 7727-43-7
123-86-4
108-65-6
75-56-9
13463-67-7
1330-20-7
T-15 THINNER, 015T0000 108-88-3
CHIPBONDER 348, 17723 30499-70-8
25068-38-6
68003-28-1
7631-86-9
39277-28-6
7585-41-3
111-40-0
13463-67-7
960172-0001 9002-83-9
VARITYPER 3025 FIXER 7772-98-7
7631-90-5
10043-35-3
7784-24-9
127-09-3
AQUA MATE CHLORIATING GRANULES-CHLORINE 2893-78-9
SK-13-1C ADHESIVE (CONCENTRATE) 5181-79-1
7732-18-5
25068-63-7
140-88-5
1344-09-8
12034-12-7
1313-59-3
7732-18-5
BACDOWN ANTIMICROBIAL HANDSOAP, 0262519 9004-82-4
57-55-6
68603-42-9
TONER TYPE 610
DPD 1A, P-6740
HYDROGEN/ARGON WELDING MIXTURES 1333-74-0
7440-37-1
K-700 DIAMOND LAPPING COMPOUND
MILTECH 237:92 COMPONENT B METCH 237:92B
US-107N, PHENOLS MIXTURE AT 2000 UG/ML IN (SUPDAT) 75-09-2
59-50-7
95-57-8
120-83-2
105-67-9
534-52-1
51-28-5
88-75-5
100-02-7
87-86-5
108-95-2
88-06-2
US-107NS, PHENOLS MIXTURE AT 2000 UG/ML IN (SUPDAT) 75-09-2
59-50-7
95-57-8
120-83-2
105-67-9
534-52-1
51-28-5
88-75-5
100-02-7
87-86-5
108-95-2
88-06-2
CLEAR OUT, COA825
KEYHOLER, KH848

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net