3M GENERAL OFFICES -- FT-12 FIT TEST SOLUTION, 70-0701-2146-5
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CCPKM
MSDS NAME: FT-12 FIT TEST SOLUTION, 70-0701-2146-5
Responsible Party
Name: 3M GENERAL OFFICES
Address: 3M CENTER
City: ST PAUL MN 55144-1000
Info Phone: 612-733-1110
Emergency Phone Number: 612-733-1110
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: MINNESOTA MINING AND MFG CO, DBA 3M
Address: 3M CENTER BLDG 224-5S-04
City: SAINT PAUL MN 55144-1000
Phone: 866-556 5712 / 612-733-1110
Name: MINNESOTA MINING AND MFG CO ENGINEERING DOCUMENT SYSTEMS DIV
Address: 3M CTR
City: SAINT PAUL MN 55144-1000
Phone: 612-737-4114
=======================================================
Ingredients
=======================================================
Cas: 7732-18-5
RTECS #: ZC0110000
Name: WATER; (DISTILLED WATER)
% Wt: 55
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 128-44-9
RTECS #: DE4550000
Name: 1,2-BENZISOTHIAZOLIN-3-ONE, 1,1-DIOXIDE, SODIUM SALT; (SODIUM SACCHARIN)
% Wt: 45
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: YES
IARC: YES
OSHA: NO
Effects of Exposure: EYE & SKIN CONTACT, INHALATION, INGESTION:NO ADVERSE
HEALTH EFFECTS ARE EXPECTED.
Explanation Of Carcinogenicity: SODIUM SACCHARIN:IARC MONOGRAPHS, SUPP, VOL 7,
PG 334, 1987:GROUP 2B. NTP 7TH ANNUAL RPT ON CARCINS, 1994:(SUPP DATA)
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHALATION:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) (FP N). SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD (FP N). EYE
CONTACT:IMMEDIATELY FLUSH EYES WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. INGESTION:DRINK 2 GLASSES OF WATER. CALL A
PHYSICIAN.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: COVER WITH ABSORBENT MATERIAL. COLLECT SPILLED
MATERIAL. CLEAN UP RESIDUE WITH WATER. PLACE IN A CLOSED CONTAINER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N). DISPOSE OF ALONG WITH HOUSEHOLD WASTE.
Handling And Storage Precautions: DO NOT INGEST.
Other Precautions: KEEP OUT OF THE REACH OF CHILDREN.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: MEDIA SUITABLE FOR SURROUNDING FIRE (FP N). NOT
APPLICABLE.
Fire Fighting Procedures: WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). NOT APPLICABLE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FP N). NOT APPLICABLE.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: ANSI APPROVED EMERGENCY EYE WASH AND DELUGE SHOWER
(FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: EXPLAN OF CARCIN:ANTICIPATED TO BE CARCINOGEN.
ANIMAL:KIDNEY, URETER, BLADDER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >212F,>100C
Vapor Pres: <20
Vapor Density: 1
PH: 7-8.5
Evaporation Rate & Reference: 1
Solubility in Water: VERY SOLUBLE
Appearance and Odor: CLEAR LIQUID; SWEET ODOR.
Percent Volatiles by Volume: 55
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: NONE KNOWN.
Hazardous Decomposition Products: NONE KNOWN.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: FT-12 FIT TEST SOLUTION, 70-0701-2146-5
Company: MINNESOTA MINING AND MFG CO ENGINEERING DOCUMENT SYSTEMS DIV
Street: 3M CTR
City: SAINT PAUL MN
Zipcode: 55144-1000
Health Emergency Phone: 612-733-1110
Label Required IND: Y
Date Of Label Review: 10/18/1996
Status Code: C
Label Date: 10/18/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE:NONE SPECIFIED BY MANUFACTURER. CHRONIC:CANCER
HAZARD. CONTAINS SODIUM SACCHARIN, WHICH IS LISTED AS AN ANIMAL KIDNEY,
URETER, BLADDER CARCINOGEN (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.