PHARMACAL RESEARCH LABORATORIE -- CLIDOX-S BASE, 961
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CHWKD
MSDS NAME: CLIDOX-S BASE, 961
Responsible Party
Name: PHARMACAL RESEARCH LABORATORIES INC
Address: 33 GREAT HILL RD
City: NAUGATUCK CT 06770
Info Phone: 800-243-5350
Emergency Phone Number: 800-424-9300 (CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: PHARMACAL RESEARCH LABS
Address: 33 GREAT HILL RD
City: NAUGATUCK CT 06770
Phone: 202-483-7616
=======================================================
Ingredients
=======================================================
Cas: 7758-19-2
RTECS #: VZ4800000
Name: SODIUM CHLORITE
% Wt: 100
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: SIGNS & SYMPTOMS OF EXPOSURE: INHALATION -
IRRITATING, SKIN - IRRITATING, INGESTION - TOXIC.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHAL: CONSULT PHYSICIAN IF IRRITATION OF RESPIRATORY PASSAGES
OCCUR. EYE CONTACT: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. SKIN
CONTACT: REMOVE CONTAMINATED CLOTHING - WASH WITH WATER. ING ESTION: SEEK
MEDICAL ATTENTION - INGESTION IS TOXIC.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: DO NOT ABSORB IN COMBUSTIBLE MATERIALS - DO NOT
REPACK. IF MATERIAL HAS ENTERED A WATER SOURCE OR SEWER OR CONTAMINATED SOIL
OR VEGETATION, ADVISE AUTHORITIES.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF CONTAINER IN CONFORMANCE WITH FEDERAL, STATE
AND LOCAL REGULATIONS.
Handling And Storage Precautions: "EMPTY" CONTAINER WARNING: RINSE THOROUGHLY
WITH WATER. KEEP CONTAINER COOL BY SPRAYING WITH WATER IF EXPOSED TO FIRE -
EXTINGUISH WITH WATER.
Other Precautions: AVOID CONTACT WITH COMBUSTIBLE OR ACID SUBSTANCES - WILL
RELEASE CHLORINE DIOXIDE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: EXTINGUISH WITH WATER.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). KEEP CONTAINERS COOL BY SPRAYING WITH WATER IF EXPOSED TO
FIRE.
Unusual Fire/Explosion Hazard: MAY REACT WITH COMBUSTIBLE SUBSTANCE CREATING
FIRE OR EXPLOSION HAZARD.
=======================================================
Control Measures
=======================================================
Protective Gloves: PLASTIC, RUBBER OR LEATHER GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N).
Work Hygienic Practices: REMOVE CLOTHING IMMEDIATELY.
Supplemental Safety and Health: VP: SAME AS WATER. VAP DENS: SAME AS WATER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 392F,200C
Vapor Pres: SUPDAT
Vapor Density: SUPDAT
PH: 11.5
Evaporation Rate & Reference: SAME AS WATER
Solubility in Water: COMPLETE
Appearance and Odor: LIGHT YELLOW CLEAR LIQUID - SLIGHT ODOR.
Percent Volatiles by Volume: 91.5
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: AVOID CONT W/COMBUSTIBLE OR ACID SUBSTANCES - WILL RELEASE
CHLORINE DIOXIDE.
Hazardous Decomposition Products: MAY REACT WITH COMBUSTIBLE SUBSTANCE CREATING
FIRE OR EXPLOSION HAZARD.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CLIDOX-S BASE, 961
Company: PHARMACAL RESEARCH LABS
Street: 33 GREAT HILL RD
City: NAUGATUCK CT
Zipcode: 06770
Health Emergency Phone: 800-424-9300 (CHEMTREC)
Label Required IND: Y
Date Of Label Review: 09/01/1998
Status Code: C
Label Date: 09/01/1998
Origination
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: SIGNS & SYMPTOMS OF EXPOSURE: INHALATION -
IRRITATING, SKIN - IRRITATING, INGESTION - TOXIC. CHRONIC: NONE LISTED BY
MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.